Germany QNix4200P5 magnetic Film Thickness Gauge split 0-5000um
The range of the German Nix QNix4200P5 is 0-5000um, which is a split Film Thickness Gauge, the principle of magnetic Induction thickness measurement, the QNix4200P/5 magnetic Film Thickness Gauge adopts Hall Sensors, and the measurement Stability is good.
Qnix-
Defelsko PRB200D Ultrasonic Thickness Gauge Probe PosiTector200D
$ 3041.00 -
LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
$ 386.00 -
LANDTEK CM8829F magnetic Film Thickness Gauge, one-piece, thickness range 0~3mm
$ 444.00 -
YIBAI CTG-600F5 Coating Thickness Gauge coating 5mm
$ 316.00 -
DUBAN DB20-CM212 Statistical Coating Thickness Gauge integrated probe 0~1250µm
$ 571.00
Introduction
Germany's QNix4200 magnetic paint Film Thickness Gauge is widely used in the fields of coatings and automotive coatings. It is a standard split coating Thickness Gauge that uses an iron-based probe. The measurement range of QNix4200P/5 is 0~5000μm. The minimum measurement diameter of the QNix4200 magnetic paint Film Thickness Gauge is 25mm and has a temperature compensation function.

product advantages
1. Simple and fast measurement
2. No calibration required
3. Automatic switch on and off
4. Large range FE: 0-5000um NFE: 0-3000um
5. Dual-purpose probe, high cost performance
6. Hall sensor makes measurement more stable
7. Sound synchronization during measurement
8. Ruby wear-resistant head, long life
9. Backlight LED display for clearer readings
10. Automatically identify the measurement substrate
11. Split probe to meet different measurement environments
plan

German NIX QNIX full range of Thickness Gauges
| model | 4200/4200P | 4500/4500P | 1200 | 1500 | 7500 | 8500 |
| matrix | Fe | Fe/NFe | Fe | Fe/NFe | Fe, NFe, Fe/NFe | Fe/NFe |
| Probe form | One body, two bodies | One body | One body, two bodies | Wired/wireless split | ||
| Measuring range | 0-3000μmââ 0-5000um | Fe:0-3000μm 0-5000um NFe: 0-3000μm | 0-2000μm | 0-5000μm | 0-2000μm 0-5000μm (optional) | |
| measurement accuracy | 0-50μm: â¤Â±1μm; 50-1000μm: â¤Â±1.5%; 1000-2000μm: â¤Â±2%; 2000-5000μm: â¤Â±3% | |||||
| Display accuracy | 0.1μm | 0-99μm: 0.1μm; 100μm-999um: 1um; above 999um, 0.01mm | 0.1um/0.01um (optional) | |||
| Operating temperature | -10 - +60℃ | |||||
| Temperature compensation | 0-50℃ | |||||
| storage | - | 1500M type | Model 7500M | Type 8500M | ||
| 3900 measured values, 999 data sets | 9999 readings, 100 data sets | |||||
| Statistics function | - | Average, maximum, minimum, standard deviation | ||||
| Over limit alarm | - | Upper and lower limits | ||||
| small matrix | 10mmÃ10mm | |||||
| small curvature | Convex and concave radius: 3mm/25mm | Convex radius: 5mm, concave radius: 25mm | ||||
| thin matrix | Fe: 0.2mm, NFe: 0.05mm | |||||
| power supply | 2 AA batteries | 1 9V alkaline battery | 2 AA batteries | |||
| weight | 110g | 130g | 150g | 130g | ||
| size | 110Ã60Ã27mm | 166Ã64Ã34mm | 110Ã60Ã24mm | 124mmÃ67mmÃ33mm | ||
Qnix QNix4200P5 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~5000μm |
| margin of error | ±3% |
| Resolution | 0.1μm|1μm |
| Minimum measurement surface | 25mm |
| Minimum radius of curvature | Convex 5mm; Concave 25mm |
| thinnest substrate | 0.2mm(F) |
| probe | Split probe |
| Probe material | ruby |
| Calibrated Certificate | Yes. |
| Calibrated mode | No need to calibrate |
| Unit display | μm |
| Interface | USB |
| Data storage | Temperature -10~60 ℃ (14~ 140 ° F) |
| Power Supply | 2 AA batteries |
| Standards | DIN EN ISO 2808, ISO 2178, ASTM B 499, ASTM D 7091 |
| Language | German, English |
| Display screen | LCD screen |
| Operating temperature | 0~50℃ |
| Machine Weight | 105g |
| Machine size | 100*60*27mm |
Qnix QNix4200P5 Coating Thickness Gauge Packing list
Host X1, probe X1, user manual X1, plastic outer box X1, Calibration plate X1, 1.5V battery X2, test certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Powder coated Film thickness measurement - steel, aluminum, wood
- Use of Magnetic Thickness Gauge
- Handheld coating Thickness Gauge several important application fields
- Film thickness measurement method of magnetic coating
- Film thickness measurement method _Defelsko comparison of several different Thickness Gauges
- Film coating thickness measurement in industrial painting and cissing coating
- How is the surface profile of precast concrete measured?
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Why Use Coating Thickness Gauges in Powder Coatings?
- What is coated Film thickness measurement?
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 42541-2023
- ActiveGB/T 7991.5-2014
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveSY/T 0315-2013
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ActiveGB/T 1740-2007
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 2361-1982
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985


QNix4200P5