LEICI WZS-186 Turbidity Meter 2000NTU
$ 1356.00 -
QIWEI ZD-10A Portable Turbidimeter 0~1000NTU
$ 235.00 -
LEICI WZT-701 Online turbidity monitor
$ 2681.00 -
YueFeng SGZ-100BJ Beer Turbidity Meter 0~100EBC
$ 568.00 -
BANTE TB200 laboratory Turbidity Meter
$ 706.00
Introduction
TP180 turbidity monitor is a digital intelligent monitoring instrument, suitable for the detection of turbidity in water in lakes, rivers, application water, swimming pools and wastewater treatment.

Features
The scattered/transmitted ratio is used instead of scattered light, and the sensor has a good linear relationship over the entire measuring range, requiring only one point of calibration, and simple maintenance
Using 128×64 dot matrix LCD module, all data, status and operation tips are Chinese display, easy to understand and easy to operate.
The instrument adopts high-precision A/D conversion and single-chip microcomputer microprocessor technology, with high performance and low power consumption.
The motherboard adopts SMD technology and highly integrated isolation circuit design, which has good anti-interference performance, stability and durability.
The standard output signal type is optional, and the alarm of the two sets of relay control switches can be set arbitrarily.
IP65 protection level, suitable for outdoor use.
The data loop storage function automatically clears the overflow data, which is convenient to operate and simple to query.
TIMEPOWER TP180 Turbidity analyzerSpecifications
| LIST | VALUE |
|---|---|
| Display mode | 128X64 dot matrix LCD, Chinese display |
| Measurement range | 0.01~4000NTU |
| Accuracy | ±1.5% F.S |
| Resolution | 0.01NTU |
| Repeatability | ±1%F.S |
| Response time | T90<1min (25℃) |
| Temperature compensation range | 0~60℃ |
| Water sample temperature | 5~60℃ |
| Environmental temperature | 5~45℃ |
| Environmental humidity | ≤ 90% RH (non-condensing) |
| Storage temperature | -25~ 55 ℃ (excluding electrode, electrode should be higher than 0 ℃) |
| Power supply Voltage | AC (85~ 265) V Frequency (45-65) Hz |
| Current Output | 0~10mA, 0~20mA, 4~ 20mA optional, load < 300Ω |
| Alarm relay | 2 normally open points can be set arbitrarily, AC220V 3A /DC30V 3A |
| Power | ≤15W |
| Protection level | IP65 |
| Power down save | > 10 years |
| Dimensions | 145*120*150mm |
| opening size | 138 mm×138mm |
| Net Weight of instrument | 0.64kg |
| Measurement range | 10NTU、100NTU、500NTU、1000NTU、5000NTU、10000NTU、20000NTU |
TIMEPOWER TP180 Turbidity analyzer Packing list
Host X1, turbidity electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- ActiveHJ 1075-2019
- ActiveHJ 1075-2019
- ActiveGB/T 18570-2009
- ISO 15715-2003


TIMEPOWER
TP180