PUSHEN Zahn-4 #Zahn Cup Zahn Cup
Viscosity range 200-1200cSt; nozzle diameter 4mm; portable; stainless steel; meets ASTM D4212 standard.
Brand
SKU: NB018124
PushenModel
VS
What else did others buy
Genuinegoods
Zahn-4#
Zahn Cup
Viscosity range 200-1200cSt; nozzle diameter 4mm; portable; stainless steel; meets ASTM D4212 standard.
Zahn Cup
It can be used anywhere in factories, workshops and laboratories to quickly check the viscosity of fluids.
Each cup has a 30 cm long ring handle that can be held by hand to submerge the cup in the liquid.
There is a ring in the center of the handle to keep the cup vertical during the test.



Standards
ASTM D 4212
Comparison of parameters of PS ZAHN Cup series
| model | cup number | outflow aperture | Measuring range | outflow time |
| PS 1024/1 | number 1 | 2 | 5-60 | 35-80 |
| PS 1024/2 | number 2 | 2.7 | 20-250 | 20-80 |
| PS 1024/3 | number 3 | 3.8 | 100-800 | 20-80 |
| PS 1024/4 | No 4 | 4.3 | 200-1200 | 20-80 |
| PS 1024/5 | Number 5 | 5.3 | 400-1800 | 20-80 |
| Unit: mm, cSt, s | ||||
| Other parameters | ||||
| Standards | ASTM D 4212 | |||
| material | Stainless steel | |||
VS
Pushen Zahn-4# Zahn CupSpecifications
| LIST | VALUE |
|---|---|
| Viscosity range | 200~1200cSt |
| outflow time | 20~80s |
| Flow hole diameter | 4.3mm |
| Cup body material | stainless steel |
| Filter material | stainless steel |
| Handle material | stainless steel |
| Applicable standard | ASTM D4212 |
| Environment temperature | 25℃±0.2℃ |
| Certificate | without |
Pushen Zahn-4# Zahn Cup Packing list
Zahn Cup X1, instruction manual X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
[Q]
Is the outflow aperture of this 4 #Zain cup 4.3mm?
[A]
Hello, the outflow aperture of the Pushen 4 #Zain cup you are looking at is 4.3mm.
[Q]
Do you have the Zahn Cup required by the ASTMD4212 standard?
[A]
This Zahn-4 #Zahn Cup will do.
[Q]
Coating viscosity measured by flow cup method, must be at the specified temperature? If not according to the specified viscosity will have any impact?
[A]
Viscosity cup measurement generally has 3 variables, viscosity, outflow time and temperature. Temperature is specified in many viscosity measurement standards because temperature has a large impact on viscosity, and the change of viscosity with temperature may not be dominant, and any diluted material used to adjust viscosity may also change the rate of this change.
+Pushen Zahn-4# Zahn Cup Big data
+Pushen Zahn-4# Zahn CupSimilar products
+Pushen Zahn-4# Zahn CupKnowledge
+Pushen Zahn-4# Zahn CupStandard
- ReplacedASTM
- ActiveGB/T 13217.4-2020
- ActiveASTM D1084-2021
- ActiveJJG 743-2018
- ActiveASTM D4212-2016
- ReplacedJJG 743-1991
- AbolishGB/T 13217.4-2008