JINGKELIAN QCJ-50 Lacquer Film Impact Height 0~50cm
Impact height 0~50cm, sub-scale 1cm, drop weight mass 1000g, Striker Diameter φ 8mm, Impact depth 2mm, die base aperture φ 15mm, pillow pad edge curvature radius 2.5~ 3.0mm
JingKeLian-
Impact Tester TQC SP1895 coating imapct Tester ASTM G14
$ 4823.00 -
JINGKELIAN QCJ-120B Paint film impact test 120cm/2000g ASTM D2794
$ 357.00 -
JINHE XCJD-5.5 Digital Display Cantilever Impact Tester Impact Speed 3.5m/s
$ 1345.00 -
JINGKELIAN TCJ Impact Resistance Tester for cracking or substrate disbonding performance of Paints varnishes
$ 574.00 -
Impact Tester TQC SP1890 meets ISO 6272-1 standard
$ 3834.00
Applications
Designed according to the GB1732---79 standard, the impact strength of the paint film is measured by using heavy objects falling from a high place to impact the paint film.
Principle
Set the hammer at the required height by the controller screw, and its height can be read from the positioning mark. Press the controller screw and the controller spring will be compressed. At this time, the round hole of the controller slider and the upper cover of the controller Align the hook with the round hole at the lower bottom of the controller, so that the connected weight falls down and hits the punch. The punch acts downward on the sample plate that was placed on the pillow block in advance, and then lifts the weight body and takes it out for testing. Passed samples to observe the paint film test on the samples.
Product storage, transport and repair
During long-distance transportation and warehouse storage, the instrument should be wrapped with moisture-proof items (plastic bags), put into a wooden box and fixed with boards, and the box should be filled with soft packing to prevent vibration. The place where the instrument is stored should be dry and the air should not contain corrosive gas.

JingKeLian QCJ-50 Film Impact DeviceSpecifications
| LIST | VALUE |
|---|---|
| Impact height | 0~50cm |
| Graduation | 1cm |
| Drop Weight Mass | 1000g |
| Striker Diameter | F8mm |
| Impact depth | 2mm |
| die base aperture | F15mm |
| Pillow block edge curvature radius | 2.5~3.0mm |
| Overall Dimensions | 250*140*830mm |
| Instrument net Weight | 11kg |
| Shipment Weight | 18kg |
JingKeLian QCJ-50 Film Impact Device Packing list
Impact X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 002-2015
- ActiveJB/T 7455-2007
- ActiveHG/T 5173-2017
- ActiveSH/T 3022-2019
- ActiveWJ 2669-2005
- Active 10302-2023
- ActiveASTM
- ActiveJT/T 821.1-2011
- ActiveDL/T 2308-2021
- ActiveJG/T 224-2007
- ActiveSY/T 4106-2016
- ActiveHG/T 5060-2016
- ActiveHG/T 4338-2012
- Active 0025-2018
- ActiveHG/T 5176-2017
- ActiveHG/T 5059-2016
- ActiveDB 44/T 1106-2012
- ActiveDB 44/T 1024-2012
- ActiveHG/T 5368-2018
- ActiveHG/T 4568-2013


QCJ-50
QCJ-100






