      Home> Viscosity Cup> Pushen> Pushen ISO-5# Flow Cup

      PUSHEN ISO-5 #ISO Flow Cup 5mm/aluminum single cup Coating viscosity Flow Cup

      Viscosity range 91~ 326cSt, outflow time 30~100s, flow hole diameter 5mm, correction factor 3.28, C value 220, cup body material anodic oxidation aluminum, filter material stainless steel, applicable standards ASTM D5125, ISO 2431.

      Brand
      SKU: NB019423
      China Pushen
      Model
      VS
      Genuinegoods
      • Pushen ISO-5# Flow CupOverview

      • Specifications
      • Comments
      • FAQs
      ISO-5#
      Flow Cup
      • PUSHEN ISO-5 #ISO Flow Cup 5mm/aluminum single cup Coating viscosity Flow Cup
      • PUSHEN ISO-5 #ISO Flow Cup 5mm/aluminum single cup Coating viscosity Flow Cup Figure 1
      • PUSHEN ISO-5 #ISO Flow Cup 5mm/aluminum single cup Coating viscosity Flow Cup Figure 2
      Viscosity range 91~ 326cSt, outflow time 30~100s, flow hole diameter 5mm, correction factor 3.28, C value 220, cup body material anodic oxidation aluminum, filter material stainless steel, applicable standards ASTM D5125, ISO 2431.

        The ISO outFlow Cup is designed and manufactured according to the relevant provisions of the international standard ISO2431-1993 Determination of outflow time by outFlow Cup for paints and varnishes and the national standard GB/T6753.4-98 Determination of paint outflow time-ISO outFlow Cup method. This outFlow Cup is used to test the outflow time of Newtonian or near-Newtonian liquids.

      Real shot of ISO outFlow Cup

      Pushhen PS1020 ISO-5 outFlow Cup front view

      Pushhen PS1020 ISO-5 outFlow Cup details

      Pushen PS1020 ISO-5 outFlow Cup outlet details

      Appearance of Pushen PS1020 ISO-5 outFlow Cup

      Equipment and Utensils

      1. Stopwatch: Accuracy 0.1 (self-provided)

      2. OutFlow Cup holder (optional)

      Instructions

      1. Before or after measurement, wipe the inner wall repeatedly with a gauze cloth dipped in the solution, twist it into a rope with soft paper, and pull it repeatedly at the outflow hole.

      2. Put the outFlow Cup on the bracket and adjust the level of the bracket.

      3. Prepare a stopwatch with an accuracy of 0.1 second, and hold the outflow hole with your hand at the same time.

      4. Slowly pour the measured liquid with a controlled temperature (according to user requirements) into the outFlow Cup to avoid air bubbles. When the liquid exceeds the mouth of the cup, use a scraper or glass to scrape it flat.

      5. Start the stopwatch and quickly release the finger holding the outflow hole, stop the stopwatch when the outflow of liquid is interrupted, and record the outflow time.

      calculation method

      The measured outflow time is calculated according to the following formula for kinematic viscosity mm/s

      cup numberISO-3
      ISO-4ISO-5ISO-6
      formulaV=0.443t-200/tV=1.37t-200/tV=3.28t-220/tV=6.90t-570/t

      Where: v=mm²/s

            t = outflow time

            Cistok = K value × outflow time - (C ÷ outflow time)

            Centipoise = centistok x specific gravity

      Note: In order to obtain more accurate data, the outflow time can be measured several times and the average value can be calculated.


      VS

      Pushen ISO-5# Flow CupSpecifications

      LIST VALUE
      Viscosity range 91~326cSt
      outflow time 30~100s
      Flow hole diameter 5mm
      Correction factor 3.28
      C value 220
      Cup height 86mm
      Cup width 56mm
      Total height 86mm
      Cup body material Aluminum anode oxidation
      Filter material stainless steel
      Applicable standard ASTM D5125,ISO 2431

      Pushen ISO-5# Flow Cup Packing list

      Viscosity cup × 1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Does this flow cup comply with ISO2431 standard?
      [A]
      This flow cup is suitable for ISO2431. Please consult customer service for detailed application definition.
      Pushen
      PUSHEN ISO-5 #ISO Flow Cup 5mm/aluminum single cup Coating viscosity Flow Cup
      Service
      Focus on online sales of Lab Testing Instruments