PUSHEN CJQ-II Film Impactor 100cm/1000g GB/T 1732
Impact height 1m, Striker Diameter φ 8mm; in line with GB/T 1732 standard; with die support, to prevent the test plate by Miscellaneous shear force.
Pushen-
CHENCHI MLQ-02 hard sheet falling ball impact test instrument 0-2mm
$ 1446.00 -
JFL QCJ-50 Film Impact 50cm/1000g
$ 220.00 -
PUSHEN TCJ-II resilience impact test instrument 100cm/1000g ISO/ASTM
$ 725.00 -
YONGLIDA QCJ-120 Film Impact Device 120cm/1000g GB/T1732
$ 335.00 -
TQC SP1880 Impact Tester meets ISO6272 and ASTMD2794 standards
$ 3853.00
CJQ-II paint film impactor
It is mainly used to test the damage degree of the paint film after being impacted. It has the advantages of simple structure and convenient operation.
A heavy hammer with a fixed weight falls on the test plate impact-coated with the sample to be tested at a certain height, and the impact force is expressed in kg.cm.
The impactor consists of a solid base with a bracket attached to the catheter, the catheter body is slotted and centered by using a collar suitable for weight
Guide the cylindrical weight to fall, with a marked height beside it to indicate the corresponding reading when the weight falls.
The impact height of Model 2702 is 0-50 cm, and the impact height of Model 2703 impactor is 0-100 cm.
The base of the instrument contains a die holder support, the punch is sized to fit the die holder,
This is important to prevent shearing of the test panel at the inner edge of the mold base.
Standards
GB/T 1732-1993 Method for Determination of Impact Resistance of Paint Film
Pushen CJQ-II Paint Film Impact Device (1m)Specifications
| LIST | VALUE |
|---|---|
| Impact height | 0~100cm |
| Graduation | 1cm |
| Drop Weight Mass | 1000g |
| Striker Diameter | Φ8mm |
| Impact depth | 2mm |
| die base aperture | Φ15mm |
| Meet the standard | GB/T 1732-1993 |
| Dimension | 200*200*1200mm |
| Shipment Weight | 15kg |
Pushen CJQ-II Paint Film Impact Device (1m) Packing list
Paint Film Impact X1, Instruction Manual X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 002-2015
- ActiveJC/T 2570-2020
- ActiveJB/T 7455-2007
- ActiveSJ 20910A-2018
- ActiveSH/T 3022-2019
- ActiveWJ 2669-2005
- Active 10302-2023
- ActiveASTM
- ActiveJT/T 821.1-2011
- ActiveDL/T 2308-2021
- ActiveJG/T 224-2007
- ActiveHG/T 5060-2016
- ActiveHG/T 4338-2012
- Active 0025-2018
- ActiveHG/T 5176-2017
- ActiveHG/T 5059-2016
- ActiveDB 44/T 1106-2012
- ActiveDB 44/T 1024-2012
- ActiveHG/T 5368-2018
- ActiveHG/T 4568-2013


CJQ-II
CJQ-II