Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> DongRu> DongRu DR260 Coating Thickness Gauge

      DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument

      Magnetic Induction, Measurement range 0~1250μm, error range +/- (1% -3%) H + 1.5μm, resolution 0.1μm /1 μm, Display screen 2.3 inch large color screen

      Brand
      SKU: NB000209
      China DongRu
      Model
      Stock
      Loading…
      Price
      $ 270.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • DongRu DR260 Coating Thickness GaugeOverview

        • Specifications
        • Comments
        • FAQs
        DR260
        Coating Thickness Gauge
        • DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
        • DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument Figure 1
        • DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument Figure 2
        Magnetic Induction, Measurement range 0~1250μm, error range +/- (1% -3%) H + 1.5μm, resolution 0.1μm /1 μm, Display screen 2.3 inch large color screen

        Coating Thickness Gauge Selection Tool

        Product Description

        Dongru DR260 Coating Thickness Tester is a magnetic coating Thickness Gauge with an external probe type, the measuring range is 0~1250 microns, and the measured thickness data is displayed on the LCD, which is clear and intuitive. The DR260 coating thickness Tester is small in size but powerful in function. It has a storage function that can store 800 measurement data. It also has two calibration methods and four statistical functions. It is easy to use, easy to operate, fast in measurement speed, high in sensitivity, High precision, continuous measurement, can be connected to PC, etc.

        Dongru DR260 coating thickness Tester new host

        Applications

        DR260 Coating Thickness Gauge is a professional non-destructive testing instrument for measuring the thickness of coated coatings on the surface of magnetic metal materials. The magnetic thickness measurement method can be used to non-destructively measure the thickness of non-magnetic coatings (galvanized, chromium, indium, enamel, rubber, powder, paint, electrophoresis, enamel, spray, Coatings, anti-corrosion and fire-proof coatings, etc.), the instrument has a precise and firm structure, good repeatability, excellent performance, easy to use, and convenient to carry.

        Applications: widely used in coating industry, manufacturing industry, metal processing industry, chemical industry, commodity inspection and other testing fields.

        Pictures

        DR260 Coating Thickness Tester Real Shot Figure 1


        DR260 Coating Thickness Tester Real Shot Figure 2


        DR260 Coating Thickness Tester Real Shot Figure 3

        Features

        • Simple operation, fast test speed, good sensitivity and high measurement accuracy

        • Alloy probe, durable and precise

        • There are two measurement methods: continuous measurement and single measurement

        • There are four statistical functions: maximum value (MAX), minimum value (MIN), average value (MEA), measurement times (No)

        • Large-capacity storage, can be stored in 10 groups, 200 in each group, and can store 2000 data in total

        • Stored data store view delete function

        • Three calibration methods: zero point calibration, two-point calibration, multi-point calibration

        • Upper and lower limit alarm function (can be set in single measurement mode)

        • The operation process is marked by a beep (in single measurement mode)

        • Automatic identification of ferrous and non-ferrous substrates

        • Metric and imperial conversion μm/Mil

        • Sunlight mode (used under strong light)

        • Chinese and English bilingual version

        • 2.3-inch large color screen large font size display

        • Manual/automatic shutdown function

        • Bluetooth synchronous data transmission function (customized)

        screen display instructions

        DR260 coating thickness Tester screen display instructions

        Instructions

        After the battery is installed on the DR260 coating thickness Tester, press the "ON/OFF" button to turn it on. After the buzzer sounds and "0" is displayed on the LCD, the instrument automatically enters the measurement state, and the probe is directly vertical and quickly tightened. Pressed onto the coating on the surface of the workpiece, the coating Thickness Gauge automatically measures the thickness of the coating through the probe, and displays the thickness value on the display (note: keep the probe vertical when measuring)


        VS

        DongRu DR260 Coating Thickness GaugeSpecifications

        LIST VALUE
        Measurement principle Magnetic Induction
        Measurement range 0 ~ 1250µm
        margin of error ±1~3%
        Resolution 0.1mm | 1mm
        Minimum radius of curvature Convex 5mm; Concave 25mm
        thinnest matrix 0.4mm
        probe F Split Probe
        Statistical function Average, MAX Maximum, MIN Minimum, Number of Tests
        icon function without
        Power Three (7) alkaline batteries
        Calibrated Certificate without
        Language Chinese, English
        Display screen 2.3-Inch large color screen and large font size display
        supporting software without
        Total Weight 100g
        Complete-built unit size 130*70*25mm
        Operating temperature 0℃~60℃
        Minimum measurement surface F11.5mm
        Relative Humidity 20~90% RH, no strong magnetic field environment
        Unit display μm / Thousand
        Shutdown method Manual/Automatic
        Measurement method Continuous measurement and single measurement
        data storage It can be stored in 10 groups, 200 in each group, and a total of 2000 data can be stored

        DongRu DR260 Coating Thickness Gauge Packing list

        host x1, standard sheet x1, iron matrix x1, battery x3, manual x1, certificate x1, cleaning cloth x1.

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is there an automatic identification function?
        [A]
        Yes, it has the function of automatically identifying ferrous and non-ferrous substrates to adapt to the measurement needs of different materials.
        [Q]
        How does DR260 perform data transmission?
        [A]
        It has Bluetooth synchronous data transmission function, allowing for customized data transmission.
        [Q]
        Does it have the upper and lower limit alarm function?
        [A]
        Yes, in Single Measurement mode, it has upper and lower limit alarm function, which can be set.
        [Q]
        What Calibration methods does the DR260 platings thickness gauge support?
        [A]
        Calibrating methods: zero-point calibrated, two-point calibrated and multi-point calibrated to ensure measurement accuracy.
        [Q]
        What Measuring method was used?
        [A]
        It adopts magnetic thickness measurement method, which can nondestructive measurement of the thickness of nonmagnetic coating on magnetic metal substrate, including various coatings and coatings.
        +DongRu DR260 Coating Thickness Gauge Big data
          +DongRu DR260 Coating Thickness GaugeSimilar products
          +DongRu DR260 Coating Thickness GaugeKnowledge
          +DongRu DR260 Coating Thickness GaugeStandard
          +Navigation
          DongRu
          DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
          Service
          Focus on online sales of Lab Testing Instruments