ZKHS GDS-010D high-low temperature Humidity Test Chamber -60~150 ℃/1000L
The inner size of ZKHS GDS-010D high-low temperature Humidity Test Chamber is 1000 * 1000 * 1000mm, the temperature range is -60 ℃~ 150 ℃, the humidity range is 30~98% R. H, the controller (7.0 inch) large screen screen programmable touch temperature and humidity controller, precision range setting accuracy.
ZKHS-
YIHENG BPS-800CA Constant Temperature and Humidity Chamber Programmable Touch Screen -20~100 ℃/800L
$ 9101.00 -
ZKHS DHS-800 Low temperature constant heating and Humidity Chamber 0~100 ℃/800L
$ 8496.00 -
Haiyoda Walk-in Constant Temperature and Humidity Test Room QD-E705-8m ³ Temperature Control -40~80 ℃
$ 26012.00 -
Aipei AP-HX-800C Programmable high and low temperature heating and humidity alternating box 800L/-40 ℃
$ 7906.00 -
ZKHS HS-500A Humidity Test Chamber RT + 10~150 ℃/500L
$ 5139.00
Description
◆The product is suitable for aerospace products, information electronic instruments, materials, electricians, electronic products, and various electronic components in high-low temperature or humid and hot environment, and inspect their performance indicators.
Cabinet structure
◆The box body is processed and formed by CNC machine tools, the shape is beautiful and generous, and the non-reaction handle is adopted, which is easy to operate.
◆ The inner tank of the box is made of imported stainless steel (SUS304) mirror panel, and the shell of the box is sprayed with A3 steel plate, which increases the appearance texture and cleanliness.
◆The water replenishment tank is placed in the lower right part of the control box, and has automatic protection for water shortage, which is more convenient for the operator to replenish the water source.
◆ The large observation window is equipped with a light to keep the box bright, and the tempered glass embedded in the heating body is used to clearly observe the situation in the box at any time.
◆ The humidification system pipeline is separated from the control circuit board, which can avoid the failure of the humidification pipeline due to water leakage and improve safety.
◆ The pipeline circuit system of the waterway system adopts the door type opening, which is convenient for maintenance and overhaul.
◆ The box body insulation is made of ultra-fine glass fiber insulation cotton, which can avoid unnecessary energy loss.
◆The left side of the box is equipped with a test hole with a diameter of 50mm, which can be used for external test power cable or signal cable.
Programmable controllers
◆The temperature and humidity control instrument adopts (7.0 inches) large screen screen, the screen operation is simple, and the program editing is easy.
The operation interface of the controller is available in Chinese and English, and the real-time operation curve diagram can be displayed on the screen.
◆ It has the capacity of 100 sets of programs and 1000 segments of 999 cycle steps, and the maximum value of each period is set to 99 hours and 59 minutes.
◆After the data and test conditions are input, the controller has the function of screen locking to avoid human touch and shutdown.
◆ With RS-232 or RS-485 communication interface, it can design programs on the computer, monitor the test process and perform automatic power on/off functions.
◆ With the function of automatic calculation, the temperature and humidity change conditions can be corrected immediately, so that the temperature and humidity control is more accurate and stable.
Refrigeration and air circulation system
◆ The refrigerator adopts the French original "Taikang" fully enclosed compressor.
◆ The refrigeration system is designed with unit or binary cryogenic circuit system.
◆ The multi-wing blower is used to supply air with strong air circulation to avoid any dead angles, which can make the temperature and humidity evenly distributed in the test area.
◆ Wind path circulation air return air design, wind pressure, wind speed are in line with the test standards, and can make the temperature and humidity at the moment of opening the door to stabilize the time quickly, the heating, cooling, humidification system is completely independent and effective, reduce the test cost, increase the life, reduce the failure rate.
Meets standards
Strictly refer to: GB/T10592-2008, GB/T10586-2006, GB/T2423.1-2008, GB/T2423.2-2008, GB/T2423.3-2006, GB/T2423.4-2008, GJB150.3A-2009, GJB150.4A-2009 and other relevant standards
Series selection
Model | GDS-100 | GDS-225 | GDS-500 | GDS-800 | GDS-010 |
Inner dimensions | 450X450X500 | 500X600X750 | 700X800X900 | 800X1000X1000 | 1000X1000X1000 |
Temperature range | A:0℃~150℃ B:-20℃~150℃ C:-40℃~150℃ D:-60℃~150℃ E:-70℃~150℃ | ||||
Humidity range | 30~98%R.H | ||||
Fluctuation/uniformity | ≤±0.5℃/≤+2℃ | ||||
Humidity deviation | +2、-3%R.H | ||||
Heating time | -20°C~100°C for about 35min | -40°C~100°C for about 45min | -70°C~100°C for about 55min | ||
Cool-down time | 25°C~-40°C for about 50min | 25°C~-60°C for about 65min | 25°C~-70°C for about 80min | ||
controller | (7.0 inches) large screen programmable touch temperature and humidity controller | ||||
Accuracy range | Setting accuracy: temperature±0.1°C, humidity±1%R.H | ||||
Temperature and humidity sensors | Platinum resistor PT100Ω/MV | ||||
Heating system | Fully self-contained, nickel-chromium alloy electrically heated heater | ||||
Humidification system | Built-in isolated, all-stainless steel shallow surface evaporative humidifier | ||||
Dehumidification system | The dew point temperature laminar flow contact dehumidification method of evaporator coil is adopted | ||||
Refrigeration system | Original French "Taikang", fully enclosed air-cooled compression refrigeration method | ||||
circulatory system | Temperature-resistant and low-noise air-conditioning motor, multi-leaf centrifugal wind wheel | ||||
Enclosure Material | A3 steel plate electrostatic spraying treatment | ||||
Inner box material | SUS304 stainless steel good mirror steel plate | ||||
Insulation material | Polyurethane rigid foam, ultra-fine glass fiber foam | ||||
Door frame insulation | Double-layer silicone rubber door sealing strip resistant to high-low temperature aging | ||||
Duration of the trial | 0~9999 M, H adjustable | ||||
Standard configuration | 1 set of multi-layer heating and defrosting glass window, 2 sample racks, and 1 test lead hole φ50mm | ||||
Security | Leakage, short circuit, overtemperature, water shortage, motor overheating, compressor overpressure, overload, overcurrent protection | ||||
Supply Voltage | AC220V±10% 50Hz AC380V±10% 50Hz three-phase five-wire system | ||||
Use ambient temperature | 5℃~+30℃ ≤85%R.H | ||||
ZKHS GDS-010D High-low temperature humidity cabinet Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Interior size | 1000*1000*1000mm |
| Temperature range | -60~150℃ |
| Humidity control range | 30~98%R.H |
| Temperature fluctuation | ≤±0.5℃ |
| Humidity Deviation | +2、-3%R.H |
| Heating rate | -20→100℃≈35min;-40→100℃≈45min |
| Cooling rate | 25~-40℃≈50min;25~-60℃≈65min |
| display | (7.0 inch) large screen screen programmable touch temperature and humidity Controller |
| Accuracy range | Setting Accuracy: temperature ± 0.1 ℃, humidity ± 1% R.H |
| Temperature transducer | Platinum resistance PT100Ω/MV |
| Heating system | Fully independent system, nickel-chromium alloy electric heating heater |
| Humidification system | Built-in isolated, all stainless steel shallow surface evaporative humidifier |
| Dehumidification system | Adopt evaporator coil dewpoint temperature laminar flow contact dehumidification method |
| Refrigeration system | Original French "Taikang", fully enclosed air-cooled compression refrigeration method |
| Circulatory system | Temperature-resistant and low-noise air-conditioned motor, multi-leaf centrifugal wind turbine |
| Enclosure Material | A3 steel plate electrostatic spray treatment |
| Inner box material | SUS304 stainless steel high quality mirror steel plate |
| Thermal insulation material | Polyurethane Rigid Foam, Ultrafine Glass Fiber Cotton |
| Door frame insulation | Double Layer High and Low Temperature Conditioning Silicone Rubber Door Seal |
| Timer | 0~9999 M, H adjustable |
| Standard configuration | Multi-layer heating and defrosting with lighting Glass window 1 set, 2 test racks, 1 test lead hole φ50mm |
| Safety Devices | Leakage, short circuit, over temperature, water shortage, motor overheating, compressor overVoltage, overload, overcurrent protection |
| Power | AC220V ± 10% 50Hz AC380V ± 10% 50Hz three-phase five-wire system |
| Environment temperature | 5~30℃ |
| Environment humidity | ≤85%R.H |
| Temperature Uniformity | ≤+2℃ |
ZKHS GDS-010D High-low temperature humidity cabinet Test Chamber Packing list
Host x1, multi-layer heating and defrosting with lighting Glass window x1 set, test rack x2, test lead hole φ50mmx1, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveIEC
- ActiveIEC
- ActiveASTM
- ActiveGB/T 2423.34-2024
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveSJ/T 10454-2020
- ActiveQX/T 16-2020
- Active 901-2021
- Active 10254-2022
- ActiveGB/T 43489-2023
- ActiveGB/T 38948-2020
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 32065.6-2015
- AbolishGB 15442.1-1995
- ActiveGB 28375-2012


GDS-010D