FANGRUI RV-SSR Digital Viscometer for small amounts of samples
FANGRUI R-SSR digital Viscometer comes standard with four rotors: 21 #, 27 #, 28 #, and 29 #. The measurement Viscosity range is 50~2000000mPa·s. If the Viscosity test is lower than 50mPa·s, a No. 0 rotor needs to be purchased. The RV-SSR adopts a backlit LCD digital display screen and provides 2 RS232 data interfaces.
FangRui-
NIRUN 6000 series, standard solution (not sold separately)
$ 220.00 -
NIRUN DV-79B set, Digital Rotational Viscometer 1~ 1.5 million cp
$ 2385.00 -
YUEPING NDJ-9S Digital Viscometer 6000000mPa · s
$ 638.00 -
Shangtian Jingyi HBT T series color screen Viscometer swirl/spin Viscosimeter 3.2 × 10 ^ 8 mPa.s
$ 2782.00 -
FANGRUI SNB-2 + DVT Digital Rotational Viscometer Real-time Viscosity Linear dispersion
$ 665.00
Introduction
The SSR series Digital Rotational Viscometer adopts a coaxial cylinder structure and uses a small sample adapter. The amount of sample required for each measurement is very small, only 7ml-13ml (No. 0 rotor is 21ml), and constant temperature water with circulation is optional. The jacket is used to control the temperature of the sample to be tested in conjunction with a constant temperature bath. The operation is very convenient and the measured value is accurate. Ideal for precious, small sample measurements.
Applications
SSR digital viscometer is widely used in fluid viscosity detection and control of oil, paint, coating, slurry, textile, food, medicine, adhesive, cosmetics, etc., to meet the viscosity test of a small number of samples.
Features
1. The level bubble is in the front, just sit and adjust the level, which is very convenient.
2. It has timing measurement function .
3. Coaxial cylinder structure .
4. The measurement accuracy of the data is two decimal places .
5. Easy and reliable operation .
6. With a small amount of sample adapter, the amount of sample required for testing is very small .
7. The viscometer is equipped with two RS232 interfaces, which can be directly connected to a miniature thermal printer and a computer .
Optional
1. Enhanced Ultra Low Viscosity Adapter ULR (Spindle 0)
Designed for low viscosity fluid measurement
Jacketed and non-jacketed specifications are available
The lowest detection limit is 1cP, the range depends on the viscometer used
Model stainless steel for easy cleaning
Can withstand the working temperature range -40 ℃ -200 ℃
2. DC0506W type viscometer dedicated low temperature constant temperature bath
Comparison of SSR parameters
| Instrument model | Rotating speed | rotor | Range | sample size |
| LV-SSR | 0.3~100 | 18#, 25#, 31#, 34# | 10,000-200,000 | 7~11 |
| RV-SSR | 0.5~100 | 21#, 27#, 28#, 29# | 6.4-2M | 7.8~11.5 |
| HA-SSR | 12.8~4M | |||
| HB-SSR | 51.2~16M | |||
| *Measuring range M=1000000; unit: r/min, mPa·s, ml | ||||
| Other parameters | ||||
| Measurement error | ±2% (Newtonian liquid) | |||
| Repeat error | ±1% (Newtonian liquid) | |||
| Output Interface | There are two RS232 interfaces, which can be connected to printers and computers | |||
| Temperature probe interface | Standard | |||
| Dimensions | 300×300×450mm | |||
FangRui RV-SSR ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | Backlit LCD, digital display |
| Measuring range | 5~2000000mPa·s |
| Rotor Specifications | 21 #, 27 #, 28 #, 29 #(0 #optional) |
| Rotor speed | 0.5/1/2/2.5/4/5/10/15/20/25/30/40/50/60/70/80/90/100rpm |
| Reproducibility | ±1%F.S |
| Measurement Accuracy | ±2% |
| Capacity | 7.8~11.5ml |
| Data Interface | There are two RS232 interfaces, which can connect printers and computers |
| Dimensions | 300*300*450mm |
| Operating language | Chinese |
| Temperature probe interface | Standard |
| No. 0 rotor (optional) range | 6.4~1K;K=1000 |
| No. 21 rotor range | 50-100K;K=1000 |
| No. 27 rotor range | 250-500K;K=1000 |
| No. 28 rotor range | 500-1M;M = 1000000 |
| No. 29 rotor range | 1K-2M万;M = 1000000 |
| ULR (No. 0 rotor) sample Volume | 21ml |
| No. 21 rotor sample Volume | 7.8ml |
| No. 27 rotor sample Volume | 11.3ml |
| No. 28 rotor sample Volume | 12.6ml |
| No. 29 rotor sample Volume | 11.5ml |
FangRui RV-SSR Viscometer Packing list
Viscometer host * 1, lifting column * 1, base * 1, 21 #, 27 #, 28 #, 29 #rotor * 1 each, connecting frame * 1, sample cylinder * 1, operation manual * 1, power adapter * 1, certificate/warranty card * 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Installation and use of Fangrui Rotational Viscometer No. 0 rotor
- How to test the viscosity of lithium battery stirring slurry?
- How to choose a Rotational Viscometer? This is enough
- Rotational viscometer selection suggestions
- Working principle and application of Spinning & weaving slurry Viscometer
- Fangrui T-type touch screen viscometer operation interface description and operation method
- What are the specific requirements for rheology of latex paint?
- What are non-Newtonian fluids?
- Thixotropic Cracking Coefficient Method for Determination of Ink Rheology
- Fangrui digital Rotational Viscometer NDJ/SNB detailed operation method
- ActiveSJ/T 10454-2020
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- AbolishGB/T 12008.7-2010
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveGB/T 12009.3-2009
- ActiveASTM D3794-2022
- ActiveASTM D1795-2021
- ActiveJJG 1002-2005
- AbolishGB/T 11175-2002
- ActiveGB/T 1981.3-2009


RV-SSR
HB-SSR
HA-SSR
LV-SSR