      Home> Thermostat> labtop> labtop iCooler-4009P External circulation high-low temperature thermostatic circulator

      LABTOP iCoolero-4009P external circulation thermostatic circulator

      LABTOP external circulation high-low temperature thermostatic circulator iCooler- 4009P adopts chilled down liquid circulation device, Temperature range -40~100 ℃, Temperature display TFT, iCooler- 4009P liquid filling volume 9L, cooling capacity (10 ℃) 2000W, a variety of operation mode optional.

      Brand
      SKU: NB030840
      China labtop
      VS
      Genuinegoods
      • labtop iCooler-4009P External circulation high-low temperature thermostatic circulatorOverview

      • Specifications
      • Comments
      • FAQs
      iCooler-4009P
      External circulation high-low temperature thermostatic circulator

      External circulation high-low temperature thermostatic circulator

      The external circulation high-low temperature constant temperature circulator products provide an economical and environmentally friendly high-low temperature constant temperature circulation solution for the laboratory. The compact design makes it quite small and very quiet to work with, and the small ones can be used directly on the table and in the fume window, and the large ones have a very small footprint. There are three types of temperature control modes for external circulation: internal control, sample control, and tracking setting control, and users can control the temperature of the tank, the temperature of external materials, and the slope according to the different temperature control methods. The program control type can also carry out 30 stages of program control, and it is very convenient for users to set the program to achieve multi-stage control such as temperature rise, constant temperature, and cooling. It is especially suitable for temperature control of glass reactors, metal reactor jackets and internal materials of reactors, as well as any application where external needs require constant temperature control.

      Detail Figure 1 of the iCooler-4009P External Circulation High and Low Temperature Thermostatic Circulator

      Features

      1. Touch screen TFT display, touch operation, small size;

      2. Proportional refrigeration and PID control technology are combined, CIT technology can directly cool down even at high temperatures.

      3. Maintenance-free pressure/suction pump, resistant to fiber and metal particle matter, long life, pump pressure and flow automatically adapt to external load, effectively protect the damage of external equipment, especially glass parts;

      4. Programmable control, 30 programs can be edited to achieve liquid temperature rise, cooling, constant temperature and other combination control (optional)

      5. Sealed Water Tank with intuitive liquid level window, which is convenient for users to observe the liquid level, and the Water Tank is equipped with a protective overflow port to prevent accidents;

      6. Stable and reliable system: high-performance and high-quality spare parts, stable quality and reliable performance.

      7. Multiple safety protection: water shortage protection, temperature protection, water pressure protection, overheating and overcurrent protection, light and sound can be reminded at the same time when alarming.

      8. When the alarm is alarmed, the light and sound are reminded at the same time, the buzzer can be set to silent or sound, and various alarm codes are directly displayed, and the error point can be directly determined

      9. Internal and external Pt100 temperature sensor, single point and two point temperature calibration, can control the temperature of external materials

      10. A variety of operation modes are optional, and the unexpected power failure can be automatically restored, which can ensure the continuous supply of cooling circulating water.

      11. Optional intelligent control function: a variety of interfaces (RS485, RS232), can remotely control the start/stop of the machine through the input of 0-10V or 4-20mA analog signal.

      12. Environmentally friendly refrigerant, no toxic pollution;

      13. The maximum temperature and minimum temperature settings of the machine can be limited

      Serial models

      ModelTemperature rangeCooling capacityheatingvolume
      iCooler-2003+-20~10045015003
      iCooler-2006+-20~10070015004.5
      iCooler-4006+-40~10080015004.5
      iCooler-2009+-20~100120015009
      iCooler-4009+-40~100150020009
      iCooler-2017+-20~1002400300017
      iCooler-2003P-20~10045015003
      iCooler-2006P-20~10070015006
      iCooler-4006P-40~10080015006
      iCooler-2009P-20~100120015009
      iCooler-4009P-40~100150020009
      Unit: °C/W/L


      VS

      labtop iCooler-4009P External circulation high-low temperature thermostatic circulatorSpecifications

      LIST VALUE
      Instrument type Chilled down liquid circulation device
      Protection level I/NFL
      Protection level IP20
      Temperature range -40~100℃
      Temperature Fluctuation 0.02K
      Temperature Display mode TFT
      Temperature Control mode Smart PID
      Temperature sensor Pt100
      Temperature sensor without
      refrigerant R404a
      Cooling Capacity 10 ℃ 2000W
      Pump type Pressure/suction pump
      Pump adjustability without
      Maximum pump pressure 1bar
      Flow rate of pump 22L/min
      Pump connection interface M16x1
      Tank Volume 9L
      Dimensions 300*500*620mm
      Temperature Resolution 0.01℃
      Light alarm Yes.
      audible alarm Yes.
      Temperature overrun alarm Yes.
      The temperature is not enough alarm without
      secondary protection without
      Low level protection without
      Calibrating options Yes.
      Allow continuous operation 100%
      Environmental temperature 5~32℃
      Allowable Relative Humidity 80%
      RS232 interface optional
      USB port optional
      Weight 35kg
      Power supply Voltage 200~230VAC/50Hz
      Instrument noise ≤45db
      Technical parameter standard DIN 12876

      labtop iCooler-4009P External circulation high-low temperature thermostatic circulator Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      What is the difference between Icooler circulators and Miscellaneous circulators?
      [A]
      Adopting proportional refrigeration technology, which is equivalent to compressor frequency conversion function, high temperature control accuracy while saving energy and reducing consumption; pressure/suction pump Stir evenly on the liquid in the water tank, can support closed external circulation, can also support open external circulation, resistant to metal and Non-metallic impurities, maintenance-free, long life; and high temperature control accuracy, one machine multi-purpose: in addition to the cooling function chill down external equipment, LABTOP icooler products can also be used as Thermostat due to high temperature control accuracy; at the same time, the temperature range is wide, easy to configure the heater, so that the temperature range expands to one hundred degrees or even higher; compact size, saves a lot of space for the laboratory
      [Q]
      Do you have the thermostatic circulator required by the GB/T26808 standard?
      [A]
      This iCoolero-4009P thermostatic circulator will do.
      [Q]
      What is the minimum temperature control for the iCoolero-4009P high and low temperature thermostatic circulator?
      [A]
      LABTOP iCoolero-4009P meets the Temperature range of -40 to 100 ° C, with a minimum temperature of -40 ° C.
      +labtop iCooler-4009P External circulation high-low temperature thermostatic circulator Big data
        +labtop iCooler-4009P External circulation high-low temperature thermostatic circulatorSimilar products
        +labtop iCooler-4009P External circulation high-low temperature thermostatic circulatorKnowledge
        +labtop iCooler-4009P External circulation high-low temperature thermostatic circulatorStandard
        +Navigation
        labtop
        LABTOP iCoolero-4009P external circulation thermostatic circulator
        Service
        Focus on online sales of Lab Testing Instruments