MODERNER QCJ-II-A film impact test device 1m GB/T1732
Impact height is 0~100cm, drop weight mass 1000g, Striker Diameter is 8 mm, die base aperture is 15 mm, meeting standard GB/T 1732.
Moderner-
PUSHEN TCJ-II resilience impact test instrument 100cm/1000g ISO/ASTM
$ 730.00 -
JINGKELIAN QJL Impact Tester film impact test instrument 120cm GB/T1723 ASTM D2794/G14
$ 821.00 -
MODERNER ZCJ Heavy-duty impact Tester for impact testing and penetration testing of various coatings for construction
Login -
YONGLIDA QCJ-120 Film Impact Device 120cm/1000g GB/T1732
$ 337.00 -
MODERNER TCJ-II 1m Elastic Impact Tester Paints, varnish Dry-Film cracking performance
Login
The QCJ-II paint film impact Tester is designed according to the GB/T1732-93 standard. It uses a heavy hammer to drop from a specific height to form an impact on the sample paint film. The impact resistance of the paint film is measured by observing the damage of the paint film. The impact resistance of the paint film is expressed by the maximum height (in centimeters) that does not cause damage to the paint film.
Detail image

Models
| name | Film impact Tester | elastic impactor | Heavy Duty Impact Tester | |
| model | QCJ-II(0.5m) | QCJ-II-A(1m) | TCJ-II (0.5m) | ZCJ |
| Impact method | ball punch | ball drop hammer | ball punch | |
| Impact height | 0~50cm | 0~100cm | 0~100c 0~40inch | 0~100cm 0~40inch |
| Weight drop | 1kg | 1kg/2Lbs | 1kg/300g | |
| Additional mass | - | 1kg/2Lbs | 1kg | |
| Steel ball diameter | 8mm | 20mm/15.9mm | 12.7mm/15.9mm | |
| Die base aperture | 15mm | 27mm/16.3mm | 16.3mm/31.75mm | |
| Dimensions | 252*140*840mm | 252×140*1340mm | 300*300*1400mm | 300*240*1400mm |
| weight | 14kg | 19kg | 18kg | |
Moderner QCJ-II-A(1m) Film impact testSpecifications
| LIST | VALUE |
|---|---|
| Impact method | Spherical Clash Top Strike |
| Impact height | 0~100cm |
| Drop Weight Mass | 1000g |
| Striker Diameter | F8mm |
| die base aperture | F15mm |
| Standards | GB/T 1732-1993 |
| Overall Dimensions | 252*140*1340mm |
| Instrument net Weight | 14kg |
Moderner QCJ-II-A(1m) Film impact test Packing list
Impact x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 002-2015
- ActiveJC/T 2570-2020
- ActiveJB/T 7455-2007
- ActiveSJ 20910A-2018
- ActiveJG/T 512-2017
- ActiveSH/T 3022-2019
- ActiveWJ 2669-2005
- ActiveASTM
- ActiveJT/T 821.1-2011
- ActiveDL/T 2308-2021
- ActiveJG/T 224-2007
- ActiveHG/T 5060-2016
- ActiveHG/T 4338-2012
- Active 0025-2018
- ActiveHG/T 5176-2017
- ActiveHG/T 5059-2016
- ActiveDB 44/T 1106-2012
- ActiveDB 44/T 1024-2012
- ActiveHG/T 5368-2018
- ActiveHG/T 4568-2013


QCJ-II-A(1m)