      NELE DC-1006-II Temperature Cycling Unit 6L/-10 ℃

      -10~200 ℃, Temperature uniformity +/- 0.05 ℃, working tank size 275 * 195 * 120mm, working tank volume 6L, groove opening size 180 * 140mm, cooling capacity 800W@20 ℃, pump Flow rate 13L/min.

      Brand
      SKU: NB034458
      China Nele
      Stock
      Loading…
      Price
      $ 1364.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Nele DC-1006-II High-low temperature circulation machineOverview

        • Specifications
        • Comments
        • FAQs
        DC-1006-II
        High-low temperature circulation machine
        • NELE DC-1006-II Temperature Cycling Unit 6L/-10 ℃
        • NELE DC-1006-II Temperature Cycling Unit 6L/-10 ℃ Figure 1
        • NELE DC-1006-II Temperature Cycling Unit 6L/-10 ℃ Figure 2
        -10~200 ℃, Temperature uniformity +/- 0.05 ℃, working tank size 275 * 195 * 120mm, working tank volume 6L, groove opening size 180 * 140mm, cooling capacity 800W@20 ℃, pump Flow rate 13L/min.

        product description

        The high-low temperature cycle integrated machine adopts the latest international professional fluorine-free refrigeration system. The main components are directly imported, and the performance is stable and reliable. Widely used in petroleum, chemical industry, electronic instrumentation, physics, chemical bioengineering, medicine and health, life science, light industry food, physical property testing and chemical analysis and other research departments, colleges and universities, enterprise quality inspection and production departments, when working for users Provide a liquid environment with controlled heat and cold, uniform and constant temperature, features: the compressor can be directly started to refrigerate at 200 degrees (without damaging the compressor), and the constant temperature test can be directly carried out on the test sample or the produced product in the tank Or the test can be used for direct heating or cooling, as a temperature source for auxiliary heating or cooling, such as temperature control for reactors, fully automatic synthesis instruments, extraction and condensation devices.

        technical features

        Fully enclosed environmental protection compressor refrigeration system, no CFC, features: the compressor can be directly started to refrigerate under the condition of 200 degrees (without damaging the compressor).

        Temperature range: optional -50~200℃ (medium is selected according to the temperature range: pure water, ethylene glycol, alcohol, methyl silicone oil).

        Temperature control function: Built-in integrated new-generation PID automatic temperature control program, built-in high-precision PT100 temperature sensor 1/3B level. Equipped with a large bright LCD, Chinese and English bilingual display, digital display resolution: 0.01 ℃, to ensure temperature stability.

        Capacity range: 6L, 10L, 15L, 20L, 30L, 50L, 100L, and non-standard products can also be designed and produced completely according to user requirements.

        Internal circulation function: Adopt a heatless centrifugal circulation pump to avoid the influence of the traditional water pump on the temperature field of the tank due to its own heat production. The internal circulation system is designed on the principle of porous U-shaped reflux circulation, which realizes the turbulence and high uniformity of the flow field and temperature field in the tank.

        The body shell adopts anti-aging electrostatic spray technology, and the liner and table are made of high-quality S304 brushed stainless steel.

        The fine workmanship of the front panel and table top of the chassis, coupled with the unique humanized R rounded corner design structure, can prevent operators from being injured by edges and corners inadvertently.

        The water release system can meet the needs of various laboratories and enterprises for liquid replacement.

        Safety protection device:

        1. With power-off protection function

        2. With upper and lower limit temperature alarm setting function

        3. Low water level protection and alarm function

        4. Temperature runaway protection and alarm function

        5. The heating device has low water level anti-dry and explosion-proof functions

        6. Multiple protection functions for compressor overheating and overcurrent

        Series selection

        modeltemperature rangeTank CapacityCooling capacity
        DC-0506-II-5~2006600
        DC-0510-II-5~20010900
        DC-0515-II-5~200151500
        DC-0520-II-5~200202000
        DC-0530-II-5~200302700
        DC-0550-II-5~200504000
        DC-05100-II-5~2001007000
        DC-1006-II-10~2006800
        DC-1010-II-10~200101200
        DC-1015-II-10~200151800
        DC-1020-II-10~200202300
        DC-1030-II-10~200303000
        DC-1050-II-10~200504300
        DC-10100-II-10~2001007500
        DC-2006-II-20~20061200
        DC-2010-II-20~200101600
        DC-2015-II-20~200152200
        DC-2020-II-20~200202700
        DC-2030-II-20~200303400
        DC-2050-II-20~200504700
        DC-20100-II-20~2001007900
        DC-3006-II-30~20061700
        DC-3010-II-30~200102100
        DC-3015-II-30~200152700
        DC-3020-II-30~200203200
        DC-3030-II-30~200303900
        DC-3050-II-30~200505200
        DC-30100-II-30~200 1008400
        DC-4006-II-40~20062300
        DC-4010-II-40~200102900
        DC-4015-II-40~200153400
        DC-4020-II-40~200203900
        DC-4030-II-40~200304600
        DC-4050-II-40~200505800
        DC-40100-II-40~2001009000
        DC-5006-II-50~20062700
        DC-5010-II-50~200103400
        DC-5015-II-50~200153900
        DC-5020-II-50~200204500
        DC-5030-II-50~200305200
        DC-5050-II-50~200506400
        DC-50100-II-50~2001009800
        Other parameters
        temperature uniformity±0.05℃
        External circulation pump flow13L/min
        When the cooling capacity is pure water at 20°C
        Unit: °C, L, W

        Optional function

        1. An optional extended external PT100 temperature sensor can detect and control the temperature of the external system in real time during external circulation.

        2. Optional built-in temperature control program of 1~30 segments can be used for automatic program temperature control and real-time display of the set temperature-time program operation status.

        3. Optional RS232 or RS485 communication interface, easy to connect to the host computer, with ModbusRTU communication protocol.

        4. The optional design and installation of a magnetic stirring system can directly carry out magnetic stirring on the liquid samples placed in the beakers in the working chamber of the constant temperature tank, without the need for an external vertical mixer, reducing redundant operations.

        5. The built-in cooling coil in the tank can be selected to quickly cool down and control the exothermic reaction of the system.

        6. An optional height-adjustable immersion loading platform can easily adjust the liquid level of the immersed sample.

        7. Horizontal shape can be selected, which has the characteristics of compact structure, lower center of gravity, and strong stability.

        VS

        Nele DC-1006-II High-low temperature circulation machineSpecifications

        LIST VALUE
        Temperature range -10~200℃
        Temperature Uniformity ±0.05℃
        Tank Size 275*195*120mm
        Tank Volume 6L
        Tank opening Dimensions 180*140mm
        Cooling Capacity 800W@20℃
        Pump flow 13L/min

        Nele DC-1006-II High-low temperature circulation machine Packing list

        host X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        What is the ultimate low temperature of this DC-1006-II high and low temperature circulator?
        [A]
        NELE DC-1006-II meets the Temperature range of -10 to 200 ° C, with a minimum temperature of -10 ° C.
        [Q]
        Can all high and low temperature circulators be used for testing in the GB/T26808 standard?
        [A]
        Not necessarily, but this DC-1006-II high and low temperature circulator can be considered.