      Home> Viscosity Cup> QiWei> QiWei BND - 4T Tu -4 Viscometer

      Qiwei BND-4T Portable Coated -4 Viscometer Pure Copper/4mm

      Qiwei BND-4T portable coating-4 Viscometer second measuring cup outflow time 0~150s, flow hole diameter 4mm, capacity 100ml, cup body material pure copper, applicable standard GB/T 1723, correction coefficient K = 1 ± 0.03.

      Brand
      SKU: NB034736
      China QiWei
      Stock
      Loading…
      Price
      $ 99.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • QiWei BND - 4T Tu -4 ViscometerOverview

        • Specifications
        • Comments
        • FAQs
        BND - 4T
        Tu -4 Viscometer

        Principle and Calculation

        The viscosity measured by the Tu-4 viscometer is the conditional viscosity, which is the time for a certain amount of sample to flow out of a hole with a specified aperture at a certain temperature, expressed in seconds. Convert the obtained sample outflow time (s) into kinematic viscosity value (mm²/s) with the following formula:

        When t<23s, t=0.154μ+11

        When 23s≤t≤150s, t=0.223μ+6.0

        In the formula:

        t——outflow time, s;

        μ—kinematic viscosity, mm²/s.

        main technical characteristics

        1. The Tu-4 viscometer is made of brass, with a capacity of about 100ml. Its geometric dimensions and inner wall roughness meet the requirements of "GB/T 1723 Method for Determination of Viscosity of Paint". The bottom is a stainless steel outflow hole.

        2. Correction coefficient K: Multiply the viscosity measured by the calibrated viscometer by the K value, which is the conditional viscosity measured by the viscometer. The correction coefficient K should be within the range of 1±0.03, otherwise the viscometer should be replaced. The viscometer should be calibrated periodically according to the frequency of its use.

        3. The difference between the measured value and the calculated value of the standard viscosity liquid with known kinematic viscosity flowing out of the Tu-4 viscometer should be within ±3% of the calculated value.

        VS

        QiWei BND - 4T Tu -4 ViscometerSpecifications

        LIST VALUE
        outflow time 0~150s
        Flow hole diameter 4mm
        Capacity 100ml
        Cup body material pure copper
        Applicable standard GB/T 1723
        Correction factor K=1±0.03

        QiWei BND - 4T Tu -4 Viscometer Packing list

        Viscosity cup × 1, certificate × 1, manual × 1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is there a difference between the two coated four cups of Pushen T-4 and Qiwei BND-4T?
        [A]
        Hello, no, it's just a different brand.
        [Q]
        Can the viscosity of nitro paint be measured by coating 4?
        [A]
        OK