CHINA Ozone Conditioning Test Chamber NBC-CY-100 For Rubber Products
CHINA Ozone Conditioning Test Chamber NBC-CY-100 with a transparent observation window, ozone concentration of 10~1000pphm, is a rubber products Conditioning Test Chamber, Temperature range 0~70 ℃.
HuiTai-
ZKHS QL-225 Ozone Aging Test Chamber Ozone Aging Test Chamber
$ 12725.00 -
HZAOC QL-500 Ozone Conditioning Test Chamber
$ 12647.00 -
ZKHS QL-150 Ozone Aging Test Chamber Ozone Aging Test Chamber
$ 11574.00 -
CHINA NBC-CY150L Ozone Aging Test Chamber 150L
$ 5683.00 -
HYQL-150 Ozone Conditioning Test Chamber 100~1000pphm
Login
Introduction
The Ozone Aging Test Chamber can be used for rubber products such as vulcanized rubber, thermoplastic rubber, cable insulation sheath and other products. Under static tensile deformation, they are exposed to airtight and dark air containing constant ozone concentration and a constant Temperature Test Chamber. Time to test the sample, from the degree of cracking or other performance changes on the surface of the sample to evaluate the ozone aging resistance of the rubber.
Ozone Sample Rack Requirements
1. It is composed of shell, electronic components and ozone generator.
2. Fix the two ends of the sample with clamps under the required elongation. When in contact with ozonated air, the length direction of the sample should be basically parallel to the airflow direction.
3. The fixture should be made of materials (such as aluminum) that are not easy to decompose ozone.
4. Make the sample rotation speed between (20^-25) mm/s, in a plane vertical to the dry air flow, each sample moves continuously along the same path
5. It takes (8^-12) min for the same sample to rotate one circle. The scanning area of the sample (the shaded part shown in Figure 2) is at least 40% of the area of the Test Chamber
6. Sample preparation should comply with the provisions of GB/T 9865.1. Specimens are to be cut from newly molded test pieces or, if desired, from finished products. The sample should be at least
7. Use at least 3 samples for each test condition
8. The width of the long standard sample is not less than 10m, the thickness is 0.2mm above 2.0m, and the length of the sample between the two ends of the clamp before stretching is not less than 40mm

HuiTai NBC-CY-100 Ozone Conditioning Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Ozone concentration range | 10~1000Pphm or 5~ 500PPM (optional) |
| Temperature range | 0℃~70℃ |
| Ozone control Accuracy | ±10% |
| Temperature Uniformity | ±2℃ |
| Temperature fluctuation | ±0.5°C |
| Humidity Accuracy | 0.1% RH |
| Relative Humidity | 60~95%RH |
| Environment temperature | RT + 10~80 ℃; -10~80 ℃ (optional) |
| Frame lift frequency | 2R/min (optional) |
| Airflow velocity | 12~16mm/s |
| Test gas flow | 20~70L/min |
| Rack speed | 360 degree swirl/spin sample holder (1 rpm) |
HuiTai NBC-CY-100 Ozone Conditioning Test Chamber Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle, structure and application of UV aging Test Chamber for aluminum-platinum tape
- Introduction of working principle and application of aging Test Chamber for industrial white oil


NBC-CY-100