METASH AA-3300F flame atomic absorption Spectrophotometer
METASH AA-3300F flame atomic absorption Spectrophotometer Atomizer single flame, Wavelength range 190~900nm, Grating line 1800/mm, Light spectrum Bandwidth 0.2/0. 4/1.0/2.0nm automatic switching, can meet the biological, environment, cosmetics, geology and other industries of metal elements conventional analysis needs.
METASH-
YueFeng FP6450 Flame photometer for cement industry, testing potassium/sodium
$ 871.00 -
YueFeng 7230G Visible Spectrophotometer without PC software
$ 661.00 -
HUXI Nano-900 UV-Visible, ultra-micro Spectrophotometer Light spectrum instrument
$ 7144.00 -
JINGHUA 756 UV-Visible Spectrophotometer 2nm Light spectrum Bandwidth 190-1100nm Wavelength range
$ 1781.00 -
YueFeng UV759 Ultraviolet-visible spectrophoto-meter Wavelength: 190m~ 1100nm
$ 1252.00
Introduction
The Spectrophotometer is designed in accordance with international standards, and the production management concept and quality management procedures in line with international standards are adopted in the production process of the instrument. The instrument has the characteristics of practicability, miniaturization, intelligence, high sensitivity, good stability, simple operation and safety, etc., which can meet the routine analysis needs of metal elements in biological, environmental, cosmetic, geological and other industries.
Instrument Features and Functions
A high degree of automation meets the needs of users
Built-in optimization parameters make it easy for users to quickly master
Automatic wavelength scanning, automatic peak finding, automatic switching of spectral bandwidth, automatic adjustment of negative high Voltage, lamp current, etc., systematic setting or single setting, flexible operation
Acetylene gas leakage alarm, real-time flame monitoring, automatic flame-out protection, and automatic power-off protection when other abnormalities occur to ensure the safety of operators and instruments
Excellent scalability, it can easily cope with the diversity and complexity of analytical samples, and easily meet a variety of analytical needs
It adopts three light stand automatic switching device to meet the needs of a variety of element tests
Using a transflective device, the energy of the sample beam and the background beam is automatically balanced when the deuterium lamp buckles the background
The atomizer and all-titanium burner with classic design ensure stable combustion and high atomization efficiency to ensure the accuracy of analysis
METASH AA-3300F Flame atomic absorption Spectrophotometer Specifications
| LIST | VALUE |
|---|---|
| Atomizer | Single flame |
| Wavelength range | 190~900nm |
| grating line number | 1800 gr/mm |
| Light spectrum Bandwidth | 0.2/0 4/1.0/2.0Nm four-speed automatic switching |
| Wavelength Accuracy | ±0.1nm |
| Wavelength Repeatability | 0.1nm |
| Baseline drift | 0.004A/30min |
| Background correction | none |
| flame analysis | Characteristic concentration (Cu): 0.02ug/ml/1%; Detection limit (Cu): 0.002ug/ml; Repeatability: RSD ≤ 0.1% |
METASH AA-3300F Flame atomic absorption Spectrophotometer Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Contrast: Use a Spectrophotometer to determine the opacity of paints and coatings
- Principle, characteristics and application of ultraviolet Spectrophotometer
- The difference between photometers at different angles
- ActiveASTM D4185-23
- ActiveGB/T 693-2024
- ActiveGB/T 14949.7-2024
- ActiveJJF 1574-2016
- ActiveGB/T 42513.4-2023
- ActiveGB/T 6150.3-2023
- ActiveGB/T 6150.1-2023
- ActiveGB/T 8151.26-2023
- ActiveGB/T 6150.15-2023
- ActiveGB/T 17593.4-2006
- ActiveGB/T 26125-2011
- ActiveGB/T 223.53-1987
- AbolishGB/T 16015-1995
- AbolishGB/T 16016-1995
- ActiveGB/T 21187-2007
- ActiveGB/T 26798-2011
- ActiveGB/T 30119-2013
- ActiveGB/T 26798-2011


AA-3300F