Bante M852 Six-in-one STIP-scan pH conductivity TDS salinity dissolved oxygen, temperature
Bante M852 six-in-one STIP-scan can measure pH, conductivity, TDS, salinity, dissolved oxygen, temperature, salinity range 0~10.00ppt, pH range -1.00~15.00pH, TDS range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt, conductivity range 0~20.00, 2000.0, 2000 µS/cm, 20.00mS/cm, Temperature Measurement range 0~60 ℃.
Bante-
Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter
$ 509.00 -
HANNA HI991405 STIP-scan
$ 455.00 -
YUEFENG SZ8113 Nitrite concentration analyzer 0~ 0.3mg/L
$ 343.00 -
YUEFENG SZ8116 iron analyzer, iron content analyzer 0~ 0.8mg/L
$ 343.00 -
TONGAO TR-4ZH Portable multiparameter water quality monitor
$ 4548.00
Measurement parameters
• pH, conductivity, TDS, salinity, dissolved oxygen, temperature
technical features
pH Unit Functional Characteristics
• Round pH sensitive membrane, fully sense the pH value of the liquid.
• 1 to 3 point calibration, automatically recognize USA or NIST standard buffer.
• Automatic temperature compensation to ensure accurate measurement of the full scale range.
• Setup menu to customize pH buffer standards, number of calibration points, temperature units, etc.
EC unit functional characteristics
• Platinum conductivity electrode, providing accurate and reliable measurement results.
• 1 to 3 point calibration, automatic identification of conductivity standard solution.
• Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
• Setup menu to customize the number of calibration points, TDS coefficient, temperature unit, etc.
DO unit functional characteristics
• Equipped with polarographic electrodes.
• 1 or 2 point calibration, using air saturated water or zero oxygen liquid.
• Salinity and barometric pressure compensation to eliminate measurement errors.
• Automatic temperature compensation to ensure accurate measurement of the full scale range.
• Setup menu to customize the number of calibration points, concentration units, temperature units, etc.
general features
•Automatic end point locking, keeping stable readings for easy viewing and recording.
• Automatic power off, effectively saving battery power consumption.
• Reset function, automatically restores the instrument to factory default settings.
Standard configuration
• M852 6-in-1 Water Quality Detector
• E201-BNC-10K triple combination pH electrode
• pH standard buffer reagents (pH4.00, 6.86, 9.18)
• CON-1-10K platinum conductivity electrode
• Conductivity standard solution (84µS/cm, 1413µS/cm, 12.88mS/cm)
• DO100 Dissolved Oxygen Electrode
• Electrolyte
• Electrode membrane cap
• 1.5V LR44 battery *9 pieces (installed in the meter)
• Carrying case
Bante M852 Six-in-one STIP-scanSpecifications
| LIST | VALUE |
|---|---|
| Salinity range | 0~10.00ppt |
| pH Measurement range | -1.00~15.00pH |
| TDS range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| Conductivity Detector Measurement range | 0~20.00, 200.0, 2000µS/cm, 20.00mS/cm |
| DO range | 0.0~20.0mg/L |
| DO% Measurement range | 0.0~200.0% |
| Temperature Measurement range | 0 ~60°C/32~140°F |
Bante M852 Six-in-one STIP-scan Packing list
M852 STIP-scan X1, E201-BNC-10K triple composite pH electrode, pH standard buffer reagent (pH4.00, 6.86, 9.18), CON-1-10K platinum Conductivity detector electrode, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm), DO100 type dissolved Oxygen electrode, electrolysis solution, electrode film cap, 1.5V LR44 battery * 9 (installed in the meter), portable case
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 8884-2017
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJJF 2105-2024
- ActiveJJG 2104-2024
- ActiveHJ 1147-2020
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveGB/T 5750.3-2023
- ActiveGB/T 41837-2022
- ActiveGB/T 17650.2-2021
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007


M852