Yoke P610 Portable Dissolved Oxygen Meter
Range 0~20.00mg/L, large screen LCD display, automatic temperature compensation, automatic salinity compensation and manual air pressure compensation functions, using combined diaphragm cap, polarographic electrode.
Yoke-
HANNA HI93701-01 Photometer reagent residual chlorine 100 times
$ 138.00 -
Qiwei YXSY-1 Portable Nitrite Tester
$ 254.00 -
TONGAO TR-205H Total Chromium (Chromium Ion) Tester
$ 786.00 -
NOBOTECH PH-1186 Industrial Online ORP Meter-1999~ + 1999mV
$ 257.00 -
HANNA HI76409A/P special PTFE dissolved oxygen film set
$ 214.00
Introduction
It is suitable for industries such as aquaculture, water source monitoring, sewage treatment and environmental monitoring, and is especially suitable for field and field use.
Features
1. Large-screen LCD display with controllable white backlight.
2. Humanized design: bracket design, convenient for customers to use. Anti-skid glove design, convenient for customers to operate.
3. The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation.
4. The polarographic dissolved oxygen electrode with a new structure can measure temperature, salinity and dissolved oxygen at the same time. Equipped with a special dissolved oxygen electrode calibration sleeve, the electrode polarization only needs 3~5 minutes.
5. Built-in microprocessor chip, with intelligent functions such as automatic calibration, data storage, function setting, automatic shutdown and low Voltage display.
6. Using the combined diaphragm cap, when replacing the sensitive membrane, just screw the new diaphragm cap on the electrode, which is very convenient to use.
7. The instrument conforms to IP57 waterproof level and can be equipped with a suitcase.
Yoke P610 P6 series dissolved oxygen analyzerSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0~20.00mg/L(ppm);0~200.0% |
| resolution | 0.1/0.01 mg/L(ppm);1/0.1% |
| Measurement Accuracy | Electric meter ± 0.10 mg/L, matching; ± 0.40 mg/L |
| Response time | ≤ 30s (25 ℃, 90% Response) |
| Residual current | ≤0.1mg/L |
| Temperature compensation range | (0~99) ℃ (automatic) |
| Salinity compensation range | 0~45ppt (manual) |
| Air pressure compensation range | 0~200kPa (manual) |
| Auto calibration | Air saturated with water; water saturated with air |
| Electrode type | polarographic |
| data storage | 150 groups |
| Save content | Numbers, measurements, Measurement Units and temperature values |
| Power | 2 AA batteries (1.5V × 2) |
| Dimensions | 65*120*31mm |
| Environment temperature | 5~ 35 ℃ (0.01 grade) |
| Environment humidity | ≤85% |
| Mass and safety certification | ISO9001:2000, CE和CMC |
| Protection class | IP57 |
| Instrument Weight | 180g |
| Suitcase size | 255×210×50mm |
| Suitcase Weight | 790g |
Yoke P610 P6 series dissolved oxygen analyzer Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Maintenance and Maintenance of Dissolved Oxygen Electrode
- The correct operation method of the dissolved Oxygen Meter [including five-minute video demonstration]
- ANLELIS DO410 Benchtop dissolved Oxygen Meter Concise operation guide
- Basic knowledge of conductivity, resistivity, TDS and salinity measurements
- How to choose the right titrator for the laboratory?
- Application value of dissolved oxygen Detector in brewery
- Water quality testing instrument FAQ collection
- How to choose the dissolved oxygen measurement method: optical method, current method, polarographic method?
- What is the importance of dissolved oxygen testing in water quality testing?
- Use of Colorimeters
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveHJ 925-2017
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018


P610