      Yoke P610 Portable Dissolved Oxygen Meter

      Range 0~20.00mg/L, large screen LCD display, automatic temperature compensation, automatic salinity compensation and manual air pressure compensation functions, using combined diaphragm cap, polarographic electrode.

      Brand
      SKU: NB039405
      China Yoke
      Model
      VS
      Genuinegoods
      • Yoke P610 P6 series dissolved oxygen analyzerOverview

      • Specifications
      • Comments
      • FAQs
      P610
      P6 series dissolved oxygen analyzer
      • Yoke P610 Portable Dissolved Oxygen Meter
      Range 0~20.00mg/L, large screen LCD display, automatic temperature compensation, automatic salinity compensation and manual air pressure compensation functions, using combined diaphragm cap, polarographic electrode.

      Introduction

      It is suitable for industries such as aquaculture, water source monitoring, sewage treatment and environmental monitoring, and is especially suitable for field and field use.

      Features

      1. Large-screen LCD display with controllable white backlight.

      2. Humanized design: bracket design, convenient for customers to use. Anti-skid glove design, convenient for customers to operate.

      3. The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation.

      4. The polarographic dissolved oxygen electrode with a new structure can measure temperature, salinity and dissolved oxygen at the same time. Equipped with a special dissolved oxygen electrode calibration sleeve, the electrode polarization only needs 3~5 minutes.

      5. Built-in microprocessor chip, with intelligent functions such as automatic calibration, data storage, function setting, automatic shutdown and low Voltage display.

      6. Using the combined diaphragm cap, when replacing the sensitive membrane, just screw the new diaphragm cap on the electrode, which is very convenient to use.

      7. The instrument conforms to IP57 waterproof level and can be equipped with a suitcase.

      VS

      Yoke P610 P6 series dissolved oxygen analyzerSpecifications

      LIST VALUE
      Measuring range 0~20.00mg/L(ppm);0~200.0%
      resolution 0.1/0.01 mg/L(ppm);1/0.1%
      Measurement Accuracy Electric meter ± 0.10 mg/L, matching; ± 0.40 mg/L
      Response time ≤ 30s (25 ℃, 90% Response)
      Residual current ≤0.1mg/L
      Temperature compensation range (0~99) ℃ (automatic)
      Salinity compensation range 0~45ppt (manual)
      Air pressure compensation range 0~200kPa (manual)
      Auto calibration Air saturated with water; water saturated with air
      Electrode type polarographic
      data storage 150 groups
      Save content Numbers, measurements, Measurement Units and temperature values
      Power 2 AA batteries (1.5V × 2)
      Dimensions 65*120*31mm
      Environment temperature 5~ 35 ℃ (0.01 grade)
      Environment humidity ≤85%
      Mass and safety certification ISO9001:2000, CE和CMC
      Protection class IP57
      Instrument Weight 180g
      Suitcase size 255×210×50mm
      Suitcase Weight 790g

      Yoke P610 P6 series dissolved oxygen analyzer Packing list

      complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      How to replace the diaphragm cap electrode?
      [A]
      The steps to replace the diaphragm cap correctly are: 1. Unscrew the diaphragm cap; 2. Clean and dry the electrodes without the diaphragm cap with pure water; 3. Wipe the cathode surface with a clean flannel or paper towel.
      [Q]
      Can dissolved oxygen meters be tested in static water?
      [A]
      No, it will affect the test results.
      [Q]
      How long does it take to dissolve oxygen meter electrode polarization?
      [A]
      3~5min。