Yoke P16 Precision pH/mV/Conductivity Detector/dissolved oxygen Measurement Instrument Multi-parameter meter
Measure pH + Conductivity Detector + dissolved oxygen, PH0.01 level, Conductivity Detector 0.5 level, dissolved oxygen polarographic film laminating method, automatically identify 8 kinds of Conductivity Detector standard solutions.
Yoke-
JINGQI WD8105 Cyanide Tester
$ 481.00 -
HANNA HI764080 Digital dissolved Oxygen electrode (built-in temperature sensor)
$ 817.00 -
YUEFENG SZ8118 nickel analyzer, nickel content analyzer 0~ 2mg/L
$ 343.00 -
LEICI calcium ion electrode calibrated solution, suitable for calcium ion composite electrode
$ 106.00 -
HANNA HI93723-01 Photometer reagent, hexavalent chromium 100 times
$ 164.00
Introduction
Multi-parameter measuring instrument for high-precision measurement in the laboratory, covering various electrochemical parameters such as pH, conductivity and dissolved oxygen. It is suitable for industries such as petroleum, chemical industry, medicine, power plant and environmental protection, and has wider applications in the fields of education and scientific research.
One machine with multiple functions: built-in pH module, conductivity module and dissolved oxygen module
Test items: pH value/mV value/conductivity/resistivity/TDS/salinity/dissolved oxygen concentration/dissolved oxygen saturation/temperature
Features
1.7-inch color high-resolution (1024*600) capacitive touch screen, UI design, navigation operation experience, high sensitivity, complete parameter display, intuitive, convenient and simple to use. The host shell is made of PEEK material, which is resistant to high temperature, corrosion and aging.
2. Built-in ARM32-bit microprocessor chip, using digital filtering and slip technology to intelligently improve the response speed of the instrument and the accuracy of measurement data. The circuit board adopts SMT patch technology, which improves the reliability of product processing.
3. The main interface of the instrument can display pH value/mV value/conductivity/dissolved oxygen concentration/dissolved oxygen saturation/temperature value at the same time. Project calibration.
4. Meet the GLP requirements of international standards, with intelligent functions such as automatic calibration, automatic temperature compensation, data storage, USB output, clock display, wireless printing, function setting and self-diagnosis information.
5. The instrument has a built-in Chinese and English bilingual operating system, humanized operation design, adjustable brightness of the instrument, and the temperature unit can be freely switched between ℃ and ℉. The instrument is equipped with a temperature electrode for automatic temperature compensation.
6. The built-in large-capacity storage can store 2000 sets of measurement data, the data can be stored and transferred through the U disk, and the stored data can be opened by the general office software EXELL, which is very convenient for customers to edit.
7. The instrument can be equipped with a Bluetooth module, which supports wireless Bluetooth printing, which is convenient for users to operate.
8. Based on the Wechat applet, you can view the instrument data in real time even if you download the program on your mobile phone.
9. The polarographic dissolved oxygen electrode with a new structure can measure temperature and dissolved oxygen at the same time, and the electrode polarization only needs 3~5 minutes. When using the combined diaphragm cap, when replacing the sensitive membrane, just screw the new diaphragm cap on the electrode, which is very convenient to use.
10. The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and automatic air pressure compensation.
11. Scalability: Different pH electrodes can be easily and quickly replaced (matching electrodes can be selected for measuring different samples) to measure pH. Replace different electrodes (electrodes with different cell constants can be selected) to measure conductivity.
12. Automatically identify 8 kinds of conductivity standard solutions, and there are two series of standard solutions to choose from: European and American series and Chinese series. Automatically identify 15 kinds of pH standard buffer solutions, there are three series of standard buffer solutions to choose from: European and American series, NIST series and Chinese series.
13. It can intelligently judge the electrode status to ensure accurate use by customers.
14. Switchable conductivity, TDS, salinity and resistivity. TDS and salinity are calculated using polynomials to ensure the conversion accuracy of the full range.
15. Comply with IP54 dust-proof and splash-proof design.
Yoke P16 Touch screen desktop three-in-oneSpecifications
| LIST | VALUE |
|---|---|
| mV range | -2000mV ~ 0 ~ 2000mV |
| pH Measurement range | (-1.99 ~ 19.99)pH |
| TDS range | 0~100g/L |
| Measurement parameters | pH, dissolved oxygen, Conductivity Detector |
| pH resolution | 0.1/0.01pH |
| pH measurement Accuracy | Electric meter: ± 0.01pH, matching: ± 0.02pH |
| Input current | ≤1×10(-12) A |
| input impedance | ≥ 3 × 10 (12) Oh |
| Stability | ±0.01pH/3h |
| Temperature compensation range | (0~100) ℃ (manual/automatic) |
| mV resolution | 1mV |
| mVAccuracy | ±0.1%FS |
| Conductivity Detector Measurement range | (0.00~20.00)μS/cm、(20.0~200.0)μS/cm、 (200~2000)μS/cm、(2.00~20.00)mS/cm、 (20.0~200.0)mS/cm、(200~2000)mS/cm(K=10) |
| Resistivity Measurement range | 0 ~ 100MZ · cm |
| Salinity range | 0~100ppt |
| Conductivity Detector resolution | 0.01/0.1/1μS/cm、0.01/0.1/1mS/cm |
| Conductivity Detector measurement Accuracy | Electric meter: ± 0.5% FS, matching: ± 1.0% FS |
| Electrode constant | 0.1 /1/10cm-1 |
| reference temperature | 25 ℃, 20 ℃ and 18 ℃ |
| DO range | 0~20.00mg/L(ppm) |
| DO resolution | 0.1/0.01 mg/L(ppm)、1/0.1 % |
| DO measurement Accuracy | Electric meter: ± 0.10mg/L, matching: ± 0.40mg/L |
| Response time | ≤ 30s (25 ℃, 90% Response) |
| Residual current | ≤0.1mg/L |
| Salinity compensation range | 0~45Ppt (automatic) |
| Air pressure compensation range | 80~105kPa (automatic) |
| Auto calibration | Air saturated with water; water saturated with air |
| Electrode type | polarographic |
| resolution | 0.1℃ |
| Measurement Accuracy | 5~ 60 ℃ range: ± 0.4 ℃; remaining range: ± 0.8 ℃ |
| data storage | 2000 groups |
| Save content | Measurement number, measurement value, temperature value, ATC or MTC status, measurement date, measurement time |
| Communication interface | USB2.0, wireless Bluetooth (optional) |
| Power | 12V/1A |
| Dimensions | 160*190*70mm |
| Weight | 880g |
| Environment temperature | Environment temperature: 5~ 35 ℃ (0.01 grade), 15~ 30 ℃ (0.001 grade) |
| Environment humidity | ≤75% |
| Protection class | IP54 |
| Mass and safety certification | ISO9001:2000,CE和CMC |
| DO% Measurement range | 0~200.0% |
| DO% Measurement range | 0~200.0% |
Yoke P16 Touch screen desktop three-in-one Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Measurement method for electrophoretic coating by conductivity meter
- Definitions for Conductivity, Resistivity, TDS and Salinity Measurements
- Basic knowledge of conductivity, resistivity, TDS and salinity measurements
- Why is conductivity important in pure water quality testing?
- Principles of two different measurement techniques for moisture determination
- Water quality testing instrument FAQ collection
- Common sense of pH meters: what every laboratory equipment user and purchaser should know
- Surface soluble salt measurement - conductivity test method
- What are the water quality testing equipment required by the laboratory?
- Understanding Conductivity Cell Constants
- ActiveGB/T 693-2024
- ActiveGB/T 8884-2017
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 126-2009
- ActiveHJ 1147-2020
- ActiveHJ 925-2017
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveGB/T 17650.2-2021
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007


P16