TONGAO TR-308H COD Ammonia Nitrogen Total Phosphorus Turbidity Tester Water Quality Analyzer
Simultaneously detect COD, ammonia nitrogen, total phosphorus, turbidity parameters, standard digestion instrument and pipette gun, digestion Colorimetric integrated tube detection, Sensitivity up to 0.001mg/L, with power-off protection function.
TongAo-
TONGAO TR-710H iron meter, water quality heavy metals Detector
$ 786.00 -
KeDiDa CT-6322 pH & Conductivity Detector Pen Range: 0.0~14.0PH/0.0~199.9US
$ 130.00 -
HANNA HI93723-01 Photometer reagent, hexavalent chromium 100 times
$ 164.00 -
HANNA HI98196/20 Water Quality Analyzer 20 meters long
$ 2196.00 -
HANNA HI2002 Desktop acidity meter pH-oxidation reduction ORP-temperature ℃ Tester
$ 719.00
Introduction
The TR-308H instrument is based on trusted certification methods - HJ/T399-2007 "Quick Digestion Spectrophotometric Method for Determination of Chemical Oxygen Demand in Water Quality", HJ535-2009 "Determination of Ammonia Nitrogen in Water Quality by Nessler's Reagent Spectrophotometry", GB11893 "Water Quality" The determination of Total phosphorus is developed and designed according to the standards of "Ammonium Molybdate Spectrophotometry" and GB13200-91 "Determination of Water Turbidity". Through imported cold light sources and narrow-band interference technology, the absorbance of the sample at a specific light source wavelength is detected spectrophotometrically, and then After the microcomputer automatically processes the data, the sample concentration value is directly displayed, expressed in units of mg/L or degrees.
The use of digestion and colorimetric integrated tube detection makes detection simpler and safer. With its compact design, fast detection, simple operation, and low cost, the instrument is widely used in wastewater detection in emergency monitoring, sewage treatment, chemical industry, pharmaceuticals, hospital wastewater, food, printing and dyeing and other industries. It can also be used in scientific research institutions, Research use of wastewater in universities, colleges and other institutions.
Features
1. Wide detection range: dozens of detection parameters can be expanded and customized according to needs to achieve better resource utilization.
2. High sensitivity: the minimum display value can reach 0.001mg/L.
3. Light source advantages: Using imported cold light source, the optical performance is better, no preheating is required, and the life span is up to 100,000 hours.
4. Intelligent operation: Intelligent operation program guides users to complete operations easily.
5. Diversified testing methods: You can choose standard measurement or continuous measurement mode, freely choose between speed and accuracy.
6. Low cost of use: low price of consumables and low usage.
7. Operational safety: Using an integrated digestion and colorimetric tube, the measurement is simple, fast and safe.
8. Large-screen LCD display, direct reading of data, simple and time-saving operation.
Emergency detection advantages
1. The instrument is compact in design, boxed in configuration, light in weight and easy to carry.
2. Equipped with special detection reagents to reduce user operations as much as possible.
3. Supports wireless Bluetooth printing and can print historical measurement data (Bluetooth printer optional).
4. Can store 4,000 sets of historical measurement data.
5. Built-in large-capacity rechargeable lithium battery with remaining power display, low power and low power consumption, achieving ultra-long standby. The digestion instrument has three power supply modes: mobile power supply, vehicle-mounted power supply, and 220V AC power supply for users to choose from.
Online operation function
Supports network port, USB interface, and Bluetooth function, and can transmit data to PC or printer.
Software advantages
1. Supports Chinese/English display (optional), friendly and intelligent design, and easy to operate.
2. Built-in system program and user program, common test items can be added to the user program for easy search.
3. It has data storage and power-off protection functions to prevent data loss and facilitate query of historical measurement data.
4. Built-in standard working procedures, no need for user calibration and calibration.
5. Users can also develop user programs and reagents to adapt to different water conditions in different situations.
6. There is a built-in help interface to explain to users the general precautions during the detection process.
7. Equipped with one-click factory reset function.
User interface example

TongAo TR-308H COD ammonia nitrogen total phosphorus turbidity TesterSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | COD, ammonia nitrogen, total phosphorus, turbidity |
| COD Measurement range | 0-10000Mg/L (segmented) |
| COD anti-chlorine interference | 1000mg/L |
| COD detection lower limit | 5mg/L |
| COD digestion environment | 165℃,15min |
| Ammonia nitrogen range | 0~50Mg/L (segmented) |
| Lower limit of ammonia nitrogen detection | 0.01mg/L |
| Ammonia nitrogen digestion environment | No need to digest |
| Total Phosphorus range | 0~20Mg/L (segmented) |
| Total phosphorus detection limit | 0.02mg/L |
| Total Phosphorus Digestion | 125℃,30min |
| Measurement range of turbidity | 0~1000Mg/L (segmented) |
| Turbidity detection lower limit | 0.5mg/L |
| Turbidity digestion environment | No need to digest |
| measurement error | ≤± 5% |
| Repeatability | ≤±5% |
| Optical inspection Stability | ≤ +/- 0.001A/20min (100,000 hours life) |
| Colorimetric method | Digestion Colorimetric Tube |
| batch Volume | 6 pcs, 16 pcs, 25 pcs (optional) |
| Data storage | 4000 records, 96 Linear dispersion (support user-defined calibration) |
| transmission method | USB data cable, LAN, Bluetooth transmission, etc. (optional) |
| printer | Portable thermal printer (optional) |
| Operating interface | Chinese/English (optional) |
| Power Supply | 5V rechargeable battery |
| Power | 0.3W |
| Host size | 240*95*80mm |
| Instrument Weight | Host: 0.5kg; Digestion instrument: 1.37kg |
| Environmental temperature | 5~40℃ |
| Environmental humidity | ≤ 85% non-condensing |
TongAo TR-308H COD ammonia nitrogen total phosphorus turbidity Tester Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Simple operation process of ammonia nitrogen reagent
- Turbidity simple operation process
- Simple operation process of total chromium reagent
- COD prefabricated reagent simple operation process (0-15000mg/L)
- Simple operation process of total phosphorus reagent
- ActiveJJF 1700-2018
- ActiveJJF 1565-2016
- ActiveJJF 1571-2016
- ActiveJJF 1424-2013
- ActiveJJF 1012-2019
- ActiveHJ 798-2016
- ActiveHJ 377-2019
- ActiveHJ 101-2019
- ActiveGB/T 7466-1987
- ActiveGB/T 11901-1989
- ActiveGB/T 33328-2016


TR-308H






