Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> STIP-scan> TongAo> TongAo TR 6900D Desktop STIP-scan

      TONGAO TR 6900D COD Ammonia Nitrogen Total Phosphorus Total Nitrogen Turbidity Suspension STIP-scan

      Simultaneously detect COD, ammonia nitrogen, Total phosphorus, Total nitrogen, turbidity, suspended solids several parameters, in line with a variety of national standards, built-in thermal printer, using digestion Colorimetric integrated tube Colorimetric.

      Brand
      SKU: NB040455
      China TongAo
      Stock
      Loading…
      Price
      $ 4517.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • TongAo TR 6900D Desktop STIP-scanOverview

        • Specifications
        • Comments
        • FAQs
        TR 6900D
        Desktop STIP-scan
        • TONGAO TR 6900D COD Ammonia Nitrogen Total Phosphorus Total Nitrogen Turbidity Suspension STIP-scan
        • TONGAO TR 6900D COD Ammonia Nitrogen Total Phosphorus Total Nitrogen Turbidity Suspension STIP-scan Figure 1
        • TONGAO TR 6900D COD Ammonia Nitrogen Total Phosphorus Total Nitrogen Turbidity Suspension STIP-scan Figure 2
        Simultaneously detect COD, ammonia nitrogen, Total phosphorus, Total nitrogen, turbidity, suspended solids several parameters, in line with a variety of national standards, built-in thermal printer, using digestion Colorimetric integrated tube Colorimetric.

        Introduction

        The instrument can quickly measure COD, ammonia nitrogen, Total phosphorus, Total nitrogen, turbidity, suspended solids, etc. Stable and reliable. Widely used in emergency monitoring, industrial wastewater, domestic (CN) sewage, sewage treatment, pharmaceutical and chemical industry, food, beverage, textile printing and dyeing, electroplating, papermaking, petroleum metallurgy, river management, scientific research units, colleges and universities and other fields.

        operating principle

        The integrated digestion colorimetric tube and the multi-channel water quality rapid analyzer can be used seamlessly, and are compatible with φ25mm colorimetric tubes.Tongao Technology TR 6900C Desktop Water Quality Detector Details Figure 1

        ● The detection of each parameter conforms to national standards, industry standards or international standards.

        ●  Built-in two COD detection methods

        Method 1: HJ/T399-2007 (national standard)

        Method 2: Import detection method

        ●  The standard detection parameters are as follows:

        - COD (premade reagents)

        - COD (powder pack reagent or custom reagent)

        - Ammonia nitrogen (NH3-N)

        - Total phosphorus (TP)   

        - Turbidity - Suspended Solids (SS)

        ●  Strong scalability in the later stage, including but not limited to the following parameters:

        - Total Nitrogen - Phosphate

        - Total chromium - Hexavalent chromium

        - Iron - Nickel

        - zinc - copper

         …

        Principle

        1. Digestion colorimetric integrated tube

        The digestion and colorimetric integrated tube is used for operation, and the digestion of the sample and the reading of the result share a reaction tube, and there is no need to transfer the liquid to the cuvette for detection.

        2. Display the result directly

        A cold light source with a specific wavelength is used to measure the absorbance of the sample, and the instrument system converts the detection result directly into the sample concentration value through a specific algorithm. 

        3. Measure multiple times and remove outliers

        Measure the water sample 10 times or more, and take the average value after removing outliers, so as to reduce the influence of dirt, scratches, fingerprints or defective glass tubes on the results.

        4. Detection of abnormal prompts

        Prompts for abnormal detection, such as prompts for blank comparison, prompts for results exceeding the upper limit of the range, etc.


        VS

        TongAo TR 6900D Desktop STIP-scanSpecifications

        LIST VALUE
        Measurement parameters COD, ammonia nitrogen, total phosphorus, total nitrogen, turbidity, suspended solids
        measurement error ≤± 5%
        Repeatability ≤±5%
        Optical inspection Stability ≤ +/- 0.001A/20min (100,000 hours life)
        Data storage 30,000 records (including item, date, time, sample ID, etc.)
        Linear dispersion quantity 96 Linear dispersions (expandable)
        printer Built-in thermal printer
        Display 5-Inch high-definition color LCD
        batch Volume 16/25 water samples/batch
        Colorimetric method Digestion Colorimetric Tube
        Sample compatibility 16 mm (round), 25mm (round)
        Communication interface USB cable, LAN, etc
        exception notification Blank comparison prompt, overrange prompt, etc
        Operating interface Membrane push-button operation, Chinese/English (optional)
        Power Supply AC(220V±10%),50Hz
        Power 5W
        Protection level IP30
        Relative Humidity ≤ 85% non-condensing
        Ambient Temperature 5~40℃
        Host size 348*250*145mm
        Instrument Weight Main unit less than 2.6kg
        COD detection method Method 1: HJ/T399-2007 standard; Method 2: Import detection method
        COD Measurement range 0-10000mg/L;0-15000mg/L
        Lower limit of COD detection 3 mg/L;2 mg/L
        COD digestion environment 165℃,15min;165℃,20min
        COD anti-chlorine interference 1000 mg/L (expandable); 1000 mg/L (expandable)
        Ammonia nitrogen detection method HJ535-2009 "Water quality, determination of ammonia nitrogen, Nessler reagent Spectrophotometric method, spec-trophotometry"
        Ammonia nitrogen range 0-50 mg/L
        Ammonia nitrogen detection lower limit 0.01mg/L
        Ammonia nitrogen digestion environment No need to digest
        Total phosphorus detection method GB11893-89
        Total Phosphorus range 0~20mg/L
        Total phosphorus detection limit 0.01mg/L
        Total Phosphorus Digestion 125℃,30min
        Turbidity detection method Spectrophotometric method, spec-trophotometry
        Turbidity Measurement range 0 ~ 1000NTU
        Lower turbidity detection limit 0.5NTU
        Turbidity digestion environment No need to digest
        Suspended solids detection method Direct Colorimetry
        Measurement range of suspended solids 0~500mg/L
        Lower limit of suspended solids detection 2mg/L
        Suspended solids digestion environment No need to digest
        TN detection method Persulfate oxidation
        TN range 0~100mg/L
        TN detection lower limit 0.5 mg/L
        TN digestion environment 125℃,30min

        TongAo TR 6900D Desktop STIP-scan Packing list

        Determination host X1, digestion instrument X1, digestion shield X1, determination reagent X1, standard solution X1, digestion Colorimetric tube X1 set, Colorimetric tube frame X1, Colorimetric tube cleaning cloth X1, host power adapter X1, USB data cable X1, simple operation flow chart X1, instruction manual X1, certificate of conformity/warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        TongAo
        TONGAO TR 6900D COD Ammonia Nitrogen Total Phosphorus Total Nitrogen Turbidity Suspension STIP-scan
        Service
        Focus on online sales of Lab Testing Instruments