TONGAO TR 6900D COD Ammonia Nitrogen Total Phosphorus Total Nitrogen Turbidity Suspension STIP-scan
Simultaneously detect COD, ammonia nitrogen, Total phosphorus, Total nitrogen, turbidity, suspended solids several parameters, in line with a variety of national standards, built-in thermal printer, using digestion Colorimetric integrated tube Colorimetric.
TongAo-
Bante901P-UK Portable multiparameter water quality measurement meter pH/Conductivity Meter
$ 535.00 -
Bante903-UK precision pH/Dissolved Oxygen Meter
$ 607.00 -
JINGQI WD8214 Lead Tester
$ 481.00 -
LEICI 780100N01 COD Precast Tube Reagent 0~150mg/L
$ 162.00 -
TONGAO TR-205H Total Chromium (Chromium Ion) Tester
$ 786.00
Introduction
The instrument can quickly measure COD, ammonia nitrogen, Total phosphorus, Total nitrogen, turbidity, suspended solids, etc. Stable and reliable. Widely used in emergency monitoring, industrial wastewater, domestic (CN) sewage, sewage treatment, pharmaceutical and chemical industry, food, beverage, textile printing and dyeing, electroplating, papermaking, petroleum metallurgy, river management, scientific research units, colleges and universities and other fields.
operating principle
The integrated digestion colorimetric tube and the multi-channel water quality rapid analyzer can be used seamlessly, and are compatible with φ25mm colorimetric tubes.
● The detection of each parameter conforms to national standards, industry standards or international standards.
● Built-in two COD detection methods
Method 1: HJ/T399-2007 (national standard)
Method 2: Import detection method
● The standard detection parameters are as follows:
- COD (premade reagents)
- COD (powder pack reagent or custom reagent)
- Ammonia nitrogen (NH3-N)
- Total phosphorus (TP)
- Turbidity - Suspended Solids (SS)
● Strong scalability in the later stage, including but not limited to the following parameters:
- Total Nitrogen - Phosphate
- Total chromium - Hexavalent chromium
- Iron - Nickel
- zinc - copper
…
Principle
1. Digestion colorimetric integrated tube
The digestion and colorimetric integrated tube is used for operation, and the digestion of the sample and the reading of the result share a reaction tube, and there is no need to transfer the liquid to the cuvette for detection.
2. Display the result directly
A cold light source with a specific wavelength is used to measure the absorbance of the sample, and the instrument system converts the detection result directly into the sample concentration value through a specific algorithm.
3. Measure multiple times and remove outliers
Measure the water sample 10 times or more, and take the average value after removing outliers, so as to reduce the influence of dirt, scratches, fingerprints or defective glass tubes on the results.
4. Detection of abnormal prompts
Prompts for abnormal detection, such as prompts for blank comparison, prompts for results exceeding the upper limit of the range, etc.
TongAo TR 6900D Desktop STIP-scanSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | COD, ammonia nitrogen, total phosphorus, total nitrogen, turbidity, suspended solids |
| measurement error | ≤± 5% |
| Repeatability | ≤±5% |
| Optical inspection Stability | ≤ +/- 0.001A/20min (100,000 hours life) |
| Data storage | 30,000 records (including item, date, time, sample ID, etc.) |
| Linear dispersion quantity | 96 Linear dispersions (expandable) |
| printer | Built-in thermal printer |
| Display | 5-Inch high-definition color LCD |
| batch Volume | 16/25 water samples/batch |
| Colorimetric method | Digestion Colorimetric Tube |
| Sample compatibility | 16 mm (round), 25mm (round) |
| Communication interface | USB cable, LAN, etc |
| exception notification | Blank comparison prompt, overrange prompt, etc |
| Operating interface | Membrane push-button operation, Chinese/English (optional) |
| Power Supply | AC(220V±10%),50Hz |
| Power | 5W |
| Protection level | IP30 |
| Relative Humidity | ≤ 85% non-condensing |
| Ambient Temperature | 5~40℃ |
| Host size | 348*250*145mm |
| Instrument Weight | Main unit less than 2.6kg |
| COD detection method | Method 1: HJ/T399-2007 standard; Method 2: Import detection method |
| COD Measurement range | 0-10000mg/L;0-15000mg/L |
| Lower limit of COD detection | 3 mg/L;2 mg/L |
| COD digestion environment | 165℃,15min;165℃,20min |
| COD anti-chlorine interference | 1000 mg/L (expandable); 1000 mg/L (expandable) |
| Ammonia nitrogen detection method | HJ535-2009 "Water quality, determination of ammonia nitrogen, Nessler reagent Spectrophotometric method, spec-trophotometry" |
| Ammonia nitrogen range | 0-50 mg/L |
| Ammonia nitrogen detection lower limit | 0.01mg/L |
| Ammonia nitrogen digestion environment | No need to digest |
| Total phosphorus detection method | GB11893-89 |
| Total Phosphorus range | 0~20mg/L |
| Total phosphorus detection limit | 0.01mg/L |
| Total Phosphorus Digestion | 125℃,30min |
| Turbidity detection method | Spectrophotometric method, spec-trophotometry |
| Turbidity Measurement range | 0 ~ 1000NTU |
| Lower turbidity detection limit | 0.5NTU |
| Turbidity digestion environment | No need to digest |
| Suspended solids detection method | Direct Colorimetry |
| Measurement range of suspended solids | 0~500mg/L |
| Lower limit of suspended solids detection | 2mg/L |
| Suspended solids digestion environment | No need to digest |
| TN detection method | Persulfate oxidation |
| TN range | 0~100mg/L |
| TN detection lower limit | 0.5 mg/L |
| TN digestion environment | 125℃,30min |
TongAo TR 6900D Desktop STIP-scan Packing list
Determination host X1, digestion instrument X1, digestion shield X1, determination reagent X1, standard solution X1, digestion Colorimetric tube X1 set, Colorimetric tube frame X1, Colorimetric tube cleaning cloth X1, host power adapter X1, USB data cable X1, simple operation flow chart X1, instruction manual X1, certificate of conformity/warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Simple operation process of ammonia nitrogen reagent
- Turbidity simple operation process
- Simple operation process of total nitrogen reagent (0-100mg/L)
- COD prefabricated reagent simple operation process (0-15000mg/L)
- Simple operation process of total phosphorus reagent
- ActiveGB/T 693-2024
- ActiveGB/T 609-2018
- ActiveJJF 1700-2018
- ActiveJJF 1565-2016
- ActiveJJF 1571-2016
- ActiveJJF 1424-2013
- ActiveJJF 1012-2019
- ActiveHJ 377-2019
- ActiveHJ 101-2019
- ActiveHG/T 5669-2019
- ActiveSL/T 788.2-2019
- ActiveGB/T 42955-2023
- ActiveGB/T 11901-1989
- ActiveGB/T 5750.3-2023
- ActiveGB/T 41837-2022
- ActiveGB/T 33328-2016


TR 6900D