HUDA Coating Humidity Chamber Damping heat testing chamber QT-E702-1000B60 -60 ℃/1000L
304 stainless steel panel, touch screen, volume 1000L, temperature control -60 ° C~ 150 ° C, mechanical binary refrigeration method, 2 French Taikang fully enclosed compressors, can be connected to printers or 232 interfaces.
HUDA-
CHINA NBC-150L-40 Semiconductor Humidity Chamber paint panel -40 ℃/150L
$ 2678.00 -
Lugong ST-225LB Humidity Chamber laboratory temperature and Humidity Test Chamber -40 ℃~ + 150 ℃
$ 3568.00 -
KESIONOTS KS-HW80E Experimental Constant Temperature and Humidity Chamber -50~ 150 ℃/80L
$ 4657.00 -
ZKHS GDJS-010C high-low temperature Humidity Cyclic Chamber -40~150 ℃/1000L
$ 13595.00 -
Factory Direct NBC-1000L-70 programmable constant temperature and humidity testing machine, paint board 1000L -70~150 ℃
$ 7066.00
Introduction
This series of constant temperature and humidity testing machines are mainly used to simulate the harsh high temperature and low temperature that may be encountered in the transportation, storage and use of electronic instruments, new materials, electricians, vehicles, metals, electronic products, aerospace materials, etc. Or hot and humid environment; or high temperature, low temperature, humid heat alternating environment, test materials, accessories or equipment high temperature resistance, cold resistance, damp heat resistance and possible damage life reduction.





Features
(1) Box structure:
1. Inner box material: SUS304# (1.0mm thick) stainless steel plate is used, which has the advantages of acid resistance, corrosion resistance and easy cleaning.
2. Enclosure Material: SUS304# (1.0mm thick) stainless steel plate is used.
3. Door handle: It adopts non-reaction, explosion-proof door handle, which is easy to operate, safe and reliable.
4. Insulation system: The insulation area is filled with ultra-fine glass fiber, and the connection parts of the inner and outer boxes are made of non-metallic high-low temperature resistant materials, which can effectively reduce temperature conduction; the door seal is made of refined silicon rubber, so that there is no aging under high-low temperature conditions And hardening phenomenon, the sealing is more reliable; the humidification method adopts isolated humidification.
5. Moving and positioning device: High-quality fixed PU movable wheels are installed at the bottom of the machine, which can easily move the machine to the designated position, and then fix the casters.
6. Sample rack: SUS304# stainless steel is punched and bent into a mesh shape, which is easy to use, and the distance between the material racks can be adjusted. The standard configuration is two pieces, and the samples are evenly distributed according to the load-bearing ≧ 20kg.
7. Test hole: open a Φ50mm test hole, and attach corresponding heat insulation accessories and special sealing soft plugs
8. Observation window: Double-layer vacuum strengthened glass is used, and the inner glued sheet-type conductive film is heated and defrosted, so that the test process can be clearly observed.
(2) Refrigeration system:
1. The refrigerating unit adopts French Taikang compressor and American DuPont environmental protection refrigerant (R404a), and adopts a binary low-temperature circuit system design, which is convenient for different temperature regions to use different compressors to work, so as to increase equipment.
2. The temperature and humidity control adopts the PID + SSR system to coordinate and control the same channel, with the function of automatic calculation, which can immediately correct the temperature and humidity changing conditions, making the temperature and humidity control more accurate and stable.
3. High-precision controllers are used for temperature and humidity, and the relative temperature and humidity performance can be set and displayed accurately, with a resolution of 0.1°C
(3) Heating and humidification system:
1. Nickel-chromium alloy high-speed heating electric heating wire is used for heating;
2. High temperature completely independent system;
3. Humidity adopts stainless steel tube with built-in nickel-chromium alloy high-speed heating electric heating wire and high-temperature magnesium oxide powder, which has fast response and long life.
4. The heating and humidification systems are completely independent, and there is an automatic water replenishment device for humidity.
(4) Control system:
1. Adopt precision liquid crystal display programmable temperature controller;
2. Intelligent digital display PID microcomputer temperature control instrument;
3. Touch setting, digital and direct display, the humidity directly displays the percentage, and the temperature sensor adopts PT100 platinum resistance Tester.
4. Temperature control adopts heat balance temperature adjustment method.
5. The program test can be done with the precise liquid crystal display programmable temperature controller, and there can be multiple groups of multi-segment programming operations, the function of setting value and program optional, and the time can be set arbitrarily.
6. The main electrical components of the equipment, such as circuit breakers and AC contactors, all use the "Chint" brand, and other electrical accessories use well-known domestic (CN) brands.
7. Convenient data processing: It can be connected to a printer or 232 communication interface, has a USB data transfer interface (U disk), can be displayed on a computer, and print temperature, humidity and time curves, providing a strong guarantee for data storage and playback during the test process.
(5) Protection system:
Overall equipment overtemperature, fan overheat protection, overall equipment phase loss/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment timing, and other protections such as leakage, operation indication, and automatic shutdown after fault alarm.
Test standard
1. GB2423.1-2008/IEC6008-2-1-2007
2. GB/T 2423.2-2008
3. GJB150.3A-2009
4. GJB150.4A-2009
5. GB2423.22-2008
6. GBT 2424.5-2006
7. GB/T 10589-2008
8. GB/T2423.3-2008 (IEC68-2-3)
HUDA QT-E702-1000B60 Programmable Humidity ChamberSpecifications
| LIST | VALUE |
|---|---|
| Interior Volume | 1000L |
| Temperature range | -60~150℃ |
| Temperature Resolution | 0.01℃ |
| Temperature Fluctuation | ≤±0.5℃ |
| Temperature Uniformity | ±2℃ |
| Humidity control range | 20~98%R.H |
| Humidity Deviation | ±2%R.H |
| Interior size | 1000*1000*1000mm |
| Dimensions | 1540mm × 2110mm (including cover) × 1380mm |
| Temperature deviation | ≤±2℃ |
| Humidity resolution | 0.1%R.H |
| Temperature control Accuracy | ±0.01℃ |
| Humidity Control Accuracy | ±0.1%RH |
| Heating rate | ≧3℃/min |
| Cooling time | ≧1℃/min |
| Refrigeration system | 1 imported French Taikang fully enclosed compressor |
| refrigerant | Environmentally friendly refrigerant R404 |
| Refrigeration system | Mechanical binary refrigeration method |
| Wind circulation | Centrifugal fan with forced circulation |
| Condenser | finned tube heat exchanger |
| Condensation method | air cooling |
| Condenser | Stainless steel brazed plate heat exchanger |
| Humidification system | Stainless steel humidifier |
| Heating system | Nickel chromium alloy stainless steel heating device |
| Water supply system | Front-mounted water supply tank, fully automatic water supply system |
| Controller | Taiwan, China Youyi Controller |
| Setup method | Chinese/English interface, touch input |
| Operation mode | Program method/fixed value method |
| Set range | Maximum Temperature range 5 ℃ |
| Display resolution | Temperature: 0.01 ℃; Time: 0.1min |
| Power-off memory function | The power failure recovery mode can be set as: hot start/cold start/stop |
| input | Platinum resistance |
| Storage function | Standard 2G SD card recording test data Linear dispersion, can upload and download data, can expand the storage Capacity |
| Safety Devices | Overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc |
| Software Operating Environment | IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system |
| Enclosure Material | SUS304 #stainless steel plate (1.0mm thick) |
| Inner box material | SUS304 #stainless steel plate (1.0mm thick) |
| Thermal insulation material | 100mm polyurethane rigid foam + 100mm high density fiberglass cotton |
| Weight | 510kg |
| Rated current | 28A |
| Rated power | 14kw |
| Power | 380V |
| Test hole diameter | 100mm |
| program amount | Maximum 120 groups, 1 program can be combined from 1 to 99 segments, Capacity: 1200 segments |
| Communication interface | 1. R232/485 communication 2. Can display Linear dispersion, data acquisition 3. Can be used as monitoring and remote Control system |
HUDA QT-E702-1000B60 Programmable Humidity Chamber Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Confusion: What is the difference between constant temperature and humidity Test Chamber, high-low Temperature Test Chamber, thermal shock Test Chamber and rapid temperature change chamber?
- How to prepare specimens and place them in a Thermostatic Chamber?
- 3 Simple Steps to Maintain Constant Temperature and Humidity Test Chamber Water Level
- Damp heat testing chamber and low-Temperature Test Chamber
- Principle, application and selection of field effect transistor programmable Humidity Chamber
- Humidity Humidity Chamber principle, application and selection
- Humidity cabinet test equipment
- ActiveIEC
- ActiveIEC
- ActiveASTM
- ActiveGB/T 2423.34-2024
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveSJ/T 10454-2020
- ActiveQX/T 16-2020
- Active 901-2021
- Active 10254-2022
- ActiveGB/T 43489-2023
- ActiveGB/T 38948-2020
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 32065.6-2015
- AbolishGB 15442.1-1995
- ActiveGB 28375-2012