      Home> Thermal Shock Test Chamber> HUDA> HUDA QD-E703-100KS40 Hot & Cold Shock climate chamber
      HUDA QD-E703-100KS40 Hot & Cold Shock climate chamber

      HUDA High and Low Temperature Thermal Shock Test Chamber QD-E703-100KS40 Three-Chamber water cooling

      Water-cooled type, Three-Chamber is divided into heat storage area, cold storage area and test area, volume 100L, cold plate baking paint outer box, temperature control -40~150 ℃, using Taiwan, CHINA touch screen programmable controller, can display Linear dispersion, for electronic components, Wire and cable testing.

      Brand
      SKU: NB041404
      China HUDA
      VS
      Information
      Genuinegoods
      • HUDA QD-E703-100KS40 Hot & Cold Shock climate chamberOverview

      • Specifications
      • Comments
      • FAQs
      QD-E703-100KS40
      Hot & Cold Shock climate chamber
      • HUDA High and Low Temperature Thermal Shock Test Chamber QD-E703-100KS40 Three-Chamber water cooling
      Water-cooled type, Three-Chamber is divided into heat storage area, cold storage area and test area, volume 100L, cold plate baking paint outer box, temperature control -40~150 ℃, using Taiwan, CHINA touch screen programmable controller, can display Linear dispersion, for electronic components, Wire and cable testing.

      Introduction

      The thermal shock testing machine is suitable for aerospace products, information electronic instruments, materials, electricians, vehicles, metals, electronic products, various electronic components, wires, cables, etc. in the environment of high-low rapid alternating environment, to test their performance indicators and quality management.

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 1

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 2

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 3

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 4

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 5

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 6

      Detail Figure 7 of QD-E703-100KS40 Thermal Shock Test Chamber

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 8

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 9

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 10

      HIYODA QD-E703-100KS40 Thermal Shock Test Chamber Details Figure 11

      Meets standards

      GJB150.5A-2009 Temperature Shock Test

      GB/2423.13-2002 Temperature shock test

      GJB360B-2009 Temperature Shock Test 

      GB2423.1-2008/IEC6008-2-1-2007 Environmental Test for Electrical and Electronic Products Part 2: Test Method Test A: Low temperature

      GBT 2423.2-2008 Environmental test for electrical and electronic products Part 2: Test method Test B: High temperature

      GBT 10589-2008 Technical conditions for low Temperature Test Chambers

      GBT 11158-2008 Technical conditions for high Temperature Test Chamber

      Operating Principle

      The pre-cooling zone, the preheating zone and the test area are independent, and the three boxes do not need to move the test product through the damper switching, and when the impact is at room temperature, the ambient temperature is introduced into the test space through the blower, and the heat or cooling capacity of the test space is excluded, and the high-low temperature tank damper is closed at the same time; when the impact is low, the high temperature and normal temperature groove damper are closed, and the low temperature tank communicates with the Test Chamber, and the pre-stored cooling capacity is introduced into the Test Chamber instantly; when the impact is at high temperature, the low temperature and normal temperature groove damper is closed, and the high temperature tank communicates with the Test Chamber, and the pre-stored heat is introduced into the Test Chamber instantly. So as to achieve the purpose of rapid alternating temperature

      Program capacity and control functions

      The number of programs that can be used: up to 120 groups, and the programs can be set to be used in connection

      Repeatable commands: each command can be executed up to 9999 times

      It has the function of high temperature start/low temperature start/normal temperature start, two or three zone impact

      It has the function of pre-heating and pre-cooling, and has the function of skipping and holding in the execution of the program

      It has 6 sets of PID parameter settings

      It has the function of power-off program memory, automatic start and continuous execution of the program after resuming power

      It has the function of temperature waiting timer

      Data acquisition, export, view graphics function

      It has the function of scheduled start and shutdown

      It has the function of adjusting the date and time

      Button and screen lock function

      Used for automatic cyclic impact or manual selective impact

      Fault medical record table display function

      The screen can be backlit adjusted, and the backlight time can be set

      . PID automatic calculation and FUZZY control

      Screen display function

      Adopt man-machine dialogue mode, touch input and control

      The actual (PV) value of the temperature setting (SV) is displayed directly

      It can display the execution program number, segment, remaining time and cycle times, and running time

      The status of the execution program action is displayed

      . The language conversion can be switched between Traditional Chinese and English

      . 7-inch LCD color display

      Safety protection device

      Refrigeration system: compressor overheating, compressor overflow, compressor overpressure, condensing fan overheating

      Test chamber: adjustable over-temperature protection, air conditioning channel limit over-temperature, fan, motor overheat relay

      Others: Total Power Phase Sequence and Phase Loss Protection Leakage Protection Overload and Short Circuit Protection Ambient Temperature Overload Protection

      Environmental conditions: The ambient temperature of the equipment should be kept within 0°C~±35°C Relative temperature: ≤85%

      1. Requirements for storage environment

      1) The ambient temperature of the equipment should be kept within 0°C~±45°C

      2) When the ambient temperature is lower than 0°C, (the equipment stops for a long time) the water stored in the equipment should be discharged cleanly, so as to avoid the water in the pipeline from freezing and damaging the pipeline

      2. Requirements for installation site

      1) Please confirm the size required for the installation of the equipment

      2The distance between the left and right sides of the Test Chamber and the rear side wall plate shall not be less than 500mm, and the front distance shall not be less than 1000mm

      3When the equipment is running, enter the door, passage, elevator, etc., whether it can be entered, so as not to affect the progress of your company's project

      controller

      1) Imported LED digital display (P, I, D+S, S, R.) microcomputer integrated controller

      2) Adopt human-computer interaction mode and touch input to allow users to quickly get started

      3) The number of programs that can be used: up to 120 groups

      4) Repeatable commands: each command can be executed 9999 times

      5) Time setting: 0~99 hours 59 minutes

      6) The graphical curve can be displayed in real time when the program is executed

      7) Display content: temperature setting (SV), actual (PV) value, execution period, program curve execution function, running time, number of stages, running time, remaining time, fault status and failure time

      8) There is a function of skipping files and holding during program execution

      9) Language selection: You can switch between Chinese and English

      10) The production of the program adopts the dialogue type, with editing, clearing, and other functions

      11) With 3 sets of time signal output control (can control the DUT ON/OFF action)

      12) It has 4 sets of PID parameter settings

      13) RS-485 interface

      14) It has the function of appointment start + appointment shutdown

      15) When the machine fails, the fault screen will be displayed and the buzzer will sound loudly

      16) It has the function of power-off program memory, automatic start and continuous execution of the program after resumption

      17) USB storage function: backup internal parameters, program setting, operation curve recording, U disk memory

      Main accessories and origin

      serial numberOriginModel brandThe name of the accessory
      1FranceTaikangCompressors (2 units)
      2CHINATaiwan, CHINAYouyicontroller
      3CHINATaiwan, CHINACHINTContactors
      4CHINATaiwan, CHINAPine poplarsensor
      5DenmarkDanfossdesiccator
      6DenmarkDanfossHigh Voltage protector
      7JapanHeron PalaceSolenoid valves
      8DenmarkDanfossOil separators
      9CHINATaiwan, CHINARain FieldCirculating fan motor
      10CHINATaiwan, CHINAVadHeater (Nichrome)
      11CHINATaiwan, CHINAGuoxinheat exchanger
      12CHINATaiwan, CHINAYongqiangevaporator
      13CHINATaiwan, CHINAShang YiCirculating wind wheels
      14United StatesEmersonShock-resistant hose
      15CHINATaiwan, CHINAZhuo YiSolid state relays
      16CHINATaiwan, CHINAYongqiangcondenser
      17United StatesR404aRefrigerant DuPont
      18ChineseR23Refrigerant DuPont
      19CHINATaiwan, CHINACHINTThermal relays
      20CHINATaiwan, CHINACHINTAC contactors
      21CHINATaiwan, CHINAYongqiangblister
      22CHINATaiwan, CHINAGuoxinPlate exchanger
      23JapanOmronMiniature relays
      24DenmarkDanfossFilter driers
      25CHINALianglingCooling water towers


      VS

      HUDA QD-E703-100KS40 Hot & Cold Shock climate chamberSpecifications

      LIST VALUE
      Inner Volume 100L
      Liner size 500*450*450mm
      Dimensions ≈1455*1790*1980mm
      Weight 650㎏
      Maximum Power 15KW
      Maximum current 30A
      Power supply conditions AC380V three-phase R, S, T, N + protective grounding
      Allowable Voltage fluctuation range 10%
      Allowable Frequency Range 50±0.5Hz
      Protective ground resistance Less than 4Ω
      Power Supply TN-S mode Power or TT mode
      Operating Environment The user is required to configure the air or power switch of the corresponding Capacity for the equipment at the installation site, and the switch must independently control the use of the equipment
      Functional requirements 1. (air) indoor space cooling and heating; 2. According to the temperature setting, the indoor space reaches the set temperature; 3. It is divided into three parts: heat storage area, cold storage area, and test area; 4. The three areas are independent, and the temperature is switched through the damper
      Operating Conditions Ambient Temperature is 0~ + 35 ℃, Relative Humidity ≤ 85%
      High Temperature Impact Range RT~170°C
      Low Temperature Impact Range RT~-60°C
      Temperature range of test area -40~150℃
      Temperature Impact Range High temperature: 60 ℃~ 150 ℃; Low temperature: -10 ℃~ -40 ℃; Room temperature: Indoor temperature
      Temperature Resolution Accuracy 0.1℃
      Temperature Fluctuation ±1℃
      Temperature Uniformity ±2.0℃
      Temperature deviation ±1℃
      Storage area Heating time RT+→170°C≈30min
      Cooling time of cold storage area RT+→-60°C≈50min
      Temperature recovery time 5 minutes
      Liner material 304 #stainless steel 1.0mm thick
      Enclosure Material Cold plate baking paint 1.5mm thick
      Thermal insulation material Polyurethane foam + fiberglass cotton 100mm thick
      Box door Single door, explosion-proof handle
      Lead Hole Open the test hole of Φ50mm, and attach the corresponding thermal insulation accessories and special sealing soft plug
      Control mode Taiwan, China Youyi LCD touch programmable Controller; main power switch, operation indicator, abnormal indicator, end indicator, defrosting indicator, power indicator, RS-232 communication interface
      Low temperature zone mechanical room Evaporator, Circulating Fan, drainage device, cold storage sheet, heating device, circulating wind wheel, volute
      High temperature zone machinery room Heating device, Circulating Fan, heat storage sheet, pressure equilibrating port, circulating wind wheel, volute
      Distribution control cabinet Total power circuit breaker, Controller, switchboard, cooling fan, over-temperature protector, cylinder, pressure protector, liquid storage tank, water-cooled condenser, refrigeration unit
      Heating system Using scale heat dissipation heating pipe P.I.D to control heating to achieve temperature equilibrate
      Refrigeration system (Optional) Using Domestic (cn-zh) high-quality chilled down water tower
      Chill down the water tower Water circulation cooling use, Flow rate 8 tons/hour
      Test material rack Stainless steel SUS #304 grille rack 2 pieces (load-bearing ≤ 20kg/piece)
      Control mode Taiwan, China Youyi Controller, control temperature
      Number of programs available Maximum 120 groups, can be set to be used in connection between programs
      Command, repeability Each command can be up to 9999 times
      RS-232 Communication interface Can display Linear dispersion, data acquisition, can be used as monitoring and remote Control system
      U disk memory card Configurable 2~ 32G memory card, can record test data for two years, bring your own.
      Operation mode Program loop mode
      Set range Adjust according to the temperature working interval of the equipment (upper limit + 5 ℃, lower limit -5 ℃)
      Display resolution Temperature: 0.1 ℃; Time: 0.1min
      input Thermocouple
      Circulatory system Low noise multi-wing long axis motor
      Heating system Imported nickel-chromium alloy electric heating device
      Heating Control mode No touchpoint equal period pulse width modulation, SSR (solid state relay)
      Control mode Anti-integral saturation PID, BTC equilibrate temperature control mode (temperature test equipment)
      subsidiary function Fault alarm and cause, processing prompt function, power-off protection function, Upper/Lower limit temperature protection function, self-diagnosis and automatic stop function
      Software Operating Environment IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system
      Temperature measurement T-Thermocouple
      Refrigeration system Duplex refrigeration system
      Refrigeration system Low temperature compressor imported from Europe
      Refrigeration system Water-cooled shell and tube condenser, chilled down water tower
      Evaporator finned tube heat exchanger
      Evaporative condenser The plate heat exchanger brazed by high temperature copper has small surface area, small energy loss and high heat exchange efficiency
      Throttle device Thermal expansion valve, capillary tubing
      Oil separator Separate the refrigerated oil droplets mixed with high temperature and high Voltage refrigerant gas discharged from the compressor and return to the compressor curved rail cavity for compressor lubrication and cooling
      refrigerant Environmentally friendly refrigerant R404A/R23
      Refrigeration system protection device Compressor overheating, compressor overcurrent, compressor overpressure, condensing fan overheating
      Protection device Adjustable over-temperature protection, air conditioning channel limit over-temperature, fan, motor overheating relay
      Protection device Total Power phase sequence and phase loss protection, leakage protection, overload and short circuit protection, Ambient Temperature protection
      Environmental conditions Ambient Temperature should be kept within 0 ℃~ + 35 ℃, Relative Humidity: ≤ 85%
      Storage environment Ambient Temperature of the equipment should be kept within 0 ℃~ + 45 ℃; when the Ambient Temperature is lower than 0 ℃, the water remaining in the equipment should be discharged cleanly (the equipment is stopped for a long time) to avoid the water in the pipeline freezing and damaging the pipeline
      Installation site requirements The distance between the left and right side panels of the test chamber and the rear side panels shall not be less than 500mm, and the distance between the front and the wall shall not be less than 1000mm

      HUDA QD-E703-100KS40 Hot & Cold Shock climate chamber Packing list

      complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      HUDA
      HUDA High and Low Temperature Thermal Shock Test Chamber QD-E703-100KS40 Three-Chamber water cooling
      Service
      Focus on online sales of Lab Testing Instruments