Aipei 2AP-CJ-80A Two-Chamber Thermal Shock Test Chamber Air-Cooled -40 ℃
Adopt temperature controller imported from Japan, temperature control -40 ° C~ + 150 ° C, volume 80L, use HFC environmentally friendly refrigerant, with paperless recording function, Thermal Shock temperature recovery time within 5 minutes.
Apkjgroup-
Aipei 3AP-CJ-150C High and Low Temperature Thermal Shock Test Chamber -65 ℃
$ 27633.00 -
Aipei 3AP-CJ-150B Three-Chamber High and Low Temperature Impact Box Air-Cooled -55 ℃
$ 23249.00 -
China domestic (CN) NBC-150E Thermal Shock Test Chamber High and Low Temperature Impact Tester
$ 14015.00 -
Aipei 2AP-CJ-50B Two-Chamber Thermal Shock Air-Cooled -55 ℃
$ 16673.00 -
ZKHS WDCJ-500C High and low temperature impact test chamber Impact hot and cold test machine -60 ℃~ 150 ℃
$ 37194.00
control instrument
The 7-inch super-large touch AP-950 programmable temperature controller independently developed by APKJ is a full touch screen controller with touch screen input. Different high-low temperature impact temperature points can be set arbitrarily according to customer requirements to meet the different needs of testing. (With temperature alarm display, real-time temperature curve display).

Applications
Widely used in industries such as electronic and electrical components and plastics, automation parts, communication components, auto parts, metals, chemical materials, plastics and other industries, defense industry, aerospace, military industry, BGA, PCB substrate, electronic chip IC, semiconductor ceramics And the physical changes of polymer materials are used to test the material structure or composite materials, which can withstand the continuous environment of extremely high temperature and extremely low temperature in an instant, so as to test its thermal expansion and contraction in the shortest time The resulting chemical or physical change.
Features
The equipment area of the second box is divided into high temperature zone and low temperature zone. The test product is placed in the basket, and the basket will move the test product into the high temperature zone or low temperature zone for impact during impact. The test product is dynamic.
Two boxes of mobile hot and cold shocks, the safe air pressure drives the test object to shock up and down.
Imported Japanese-made color touch LCD Chinese/English microcomputer temperature controller.
Paperless recording function, with dual functions of real-time display of temperature shock test change curves and recording.
The movement time of the hot and cold impact mechanism is within 10 seconds, which can meet the specifications of MIL, LEC, JIS and so on.
The thermal shock temperature recovery time is within 5 minutes, which can meet the relevant test specifications.
Using HFC environmental protection refrigerant, binary ultra-low temperature refrigeration system design, fast cooling and high efficiency.
Standards
GB/T2423.1-2008 Test method of low temperature test
GB/T2423.2-2008 Test method of high temperature test
GB/T2423.22-2012 Test of temperature change test
GJB150.5-86 temperature shock test Test of temperature shock
GJB360.7-87 Test of temperature shock
GJB367.2-87 Test of temperature shock
QC/T17-92, EIA364-32, IEC68-2-14, etc.
Advantages of insulation materials
Box insulation material: rigid polyurethane foam, its advantages are:
1. Effective energy saving, no gaps after filling, strong bonding after curing.
2. Shockproof and compressive, no cracking, no corrosion, no falling off after curing.
3. It has ultra-low temperature thermal conductivity, weather resistance and heat preservation.
4. Effective insulation, sound insulation, waterproof and moisture-proof after curing.
5. Good waterproof performance, because the foam holes are closed, the sealing rate reaches 95%, rainwater will not seep through the holes.
The name and function of each part of the test box
①High temperature room: used to store heat
②LABOratory: The part where the sample is placed for testing
③Low temperature room: used to store cold energy
④ Main power board: including main power switch, sample power control terminal, external alarm output terminal, test end output terminal, temperature arrival output terminal, RS-232 communication interface, operation panel cover lock
⑤ Operation panel: including controller, fault indicator light, over-temperature protection setting device, temperature Recorder (optional)
⑥Power distribution room: install electrical components
⑦Mechanical room: install refrigeration unit and exhaust fan
⑧Inlet: Inhale outside air when exposed to ambient temperature
⑨Exhaust port: Exhaust hot air from the mechanical room and test room
⑩The temperature Recorder (optional) records the temperature of each chamber of the temperature shock Test Chamber
safety device
1. Refrigeration system: compressor overpressure, compressor overheating, compressor overcurrent, circulating cooling water supply underpressure
2. LABOratory: over-high-low protection of the test room (built-in controller), over-high-low protection of the test room, and door opening protection of the test room
3. Others: Total power supply phase sequence and phase loss protection relay, leakage circuit breaker, sample power supply control terminal, external alarm output terminal, high/low temperature room over-temperature protection switch, high/low temperature room over-temperature protection (built-in controller) , circulation fan thermal relay, motor temperature switch, compressed air pressure switch, exhaust valve
other configuration
※The user is required to configure an air or power switch of corresponding capacity at the installation site, and this switch needs to be independently used by this equipment AC380V power supply requirements:
1. Three-phase four-wire + protective ground wire
2. Voltage range: AC (380±10) V
3. Allowable fluctuation range of frequency: (50±0.5) Hz
4. The grounding resistance of the protective wire is less than 4Ω
This plan does not include ventilation pipes, power supply (leakage switch), air source (Air Compressor), water source (bottled water or water pipes) and other equipment external environment project installation
Apkjgroup 2AP-CJ-80A Thermal Shock Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -40 ℃~ + 150 ℃ (air-cooled) |
| Temperature fluctuation | ±0.5℃ |
| Temperature deviation | ±2.0℃ |
| Weight | About 550kg |
| Inner Volume | 80L |
| Liner size | 400*500*400mm |
| Overall Dimensions | 1400*1950*1850mm |
| Low Temperature Impact Range | -10 ℃~ -40 ℃ (optional) |
| High Temperature Impact Range | 60 ℃~ 150 ℃ (arbitrarily adjustable) |
| Test environmental conditions | The temperature of the environment around the machine is maintained between + 25~ + 30 ℃, Relative Humidity: ≤ 85%; air pressure: 86kPa~ 106kPa normal atmospheric pressure. |
| High Temperature Impact Range | RT~+195°C |
| Heating rate | + 50 ℃ → + 195 ℃ ≤ 40min; Note: The heating time is the performance of the high greenhouse running alone |
| Low Temperature Impact Range | RT~-55°C |
| Cooling time | + 20 ℃ → -55 ℃ ≤ about 90min; Note: The cooling time is the performance of the low greenhouse running alone |
| Test method | Place the product in the gondola test area, two boxes of mobile heat & cold shock, safe air pressure to drive the test object up and down Impact. |
| Temperature recovery time | ≤ 5min; the conversion temperature only needs ≤ 10s (the movement time of the hanging basket: within 3 seconds) |
| Impact exposure time | ≥30min |
| Outer wall material | The outer material can be selected from SUS304 high-quality stainless steel or fine powder paint treatment |
| Liner material | The inner plate material is high-quality SUS304 stainless steel, with good corrosion resistance, heat resistance, low temperature strength and mechanical properties; stamping, bending and other hot workability, no heat treatment hardening phenomenon (no magnetic, operating temperature -196 ℃~ 800 ℃) |
| Box insulation material | Rigid polyurethane foam |
| Air conditioning channel | Fan, heater, evaporator, damper, temperature transducer |
| Specimen shelf | 1 set, a total of two layers (with four hooks) bearing 25KG (please indicate when placing an order for larger bearing) |
| Lead Hole | (Optional) 1, located on the left side of the box, with a round hole with a size of φ50mm |
| Test chamber door | Single open, left hinge, right handle |
| Circulating Fan | High temperature/ring temperature exposure: 3φ, 400W, centrifugal; low temperature exposure: 3φ, 400W, centrifugal |
| Control Panel | Controller display, fault indicator, timer, USB or R232 interface, over-temperature protection setter, main power switch |
| Machinery room | Refrigeration unit, connected to drainage device, exhaust fan |
| Distribution control cabinet | Total power leakage circuit breaker, Controller, switchboard, cooling fan, high and low temperature Circulating Fan motor |
| Heating system | Nickel-chromium alloy heating wire heater |
| Heater control method | No touchpoint equal period pulse width modulation, SSR (solid state relay) |
| Power cord holes and drain holes | On the back of the box |
| Refrigeration system | France Taikang or Japan Hitachi fully enclosed low noise rotary compressor |
| Evaporator | finned tube heat exchanger |
| Condenser | Shell and tube heat exchanger |
| Throttle device | Thermal expansion valve, capillary |
| Evaporative condenser | Stainless steel brazed plate heat exchanger |
| Refrigerator control method | The PLC (programmable logic Controller) of the Control system automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, the energy adjustment circuit, and the condensing pressure control valve according to the test conditions |
| refrigerant | R404a/R23 (ozone depletion index is 0) |
| Controller model | Programmable Controller, touch screen input, different high and low temperature Impact temperature points can be arbitrarily set according to customer requirements to meet different needs for testing |
| display | LCD liquid crystal display |
| Operation mode | procedural method |
| Setup method | All Chinese liquid crystal display (Chinese and English can be switched) LCD touch panel (resistant to 100.000 line drawing test) |
| Program Capacity | Up to 120 groups, each program is divided into three areas, three areas and 3 segments. Each command can reach 999 times; the program segment time is set to 0~999Hour59Min. |
| Display resolution | Temperature: 0.1 ℃; Time: 0.1min |
| Electrical input | thermocouple |
| storage device | USB and R232 communication interface |
| Control method | Anti-integral saturation PID, fuzzy algorithm; BTC equilibrate temperature control method |
| Curve recording | Real-time display of graphics during program execution Linear dispersion |
| subsidiary function | With power-off program memory, it automatically starts and continues to execute program functions after power-back, with date, time adjustment, reservation start, shutdown function and screen lock (LOCK) function. |
| Environmental conditions | Temperature: 5 ℃~ 35 ℃; Relative Humidity: ≤ 85%; air pressure: 86kPa~ 106kPa normal atmospheric pressure. |
| Air source pressure | ( 5 ~ 7 ) kg / cm2 |
| Air source connecting pipe diameter | fo8mm |
| Air source flow | 0.1m3/min |
| Maximum current consumption | Current: 18A; Power: about 12.0KW [Voltage range: no more than +/- 10%] |
| Storage environment | When the equipment is not working, the temperature of the environment should be kept within 0 ℃~ + 45 ℃; when the environment temperature is lower than 0 ℃, the water remaining in the equipment should be discharged cleanly to prevent the water in the pipeline from freezing and damaging the pipeline. |
Apkjgroup 2AP-CJ-80A Thermal Shock Test Chamber Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- "Two-Chamber" and "Three-Chamber" heat & cold shock boxes, which one is more suitable for you?
- Stone strike resistance of paint film and its test method
- Precision heat & cold shock testing device
- Principle, Application and Selection of Main board Thermal Shock Test Chamber
- Thermal Shock Test Chamber for printed circuit boards


2AP-CJ-80A
2AP-CJ-80C
2AP-CJ-80B






