YUEFENG FP6423 Flame photometer Calcium Ca/Ba
Calcium and barium elements were tested in the ranges of 0-25mmol/L and 0-22mmol/L, respectively. Liquefied petroleum gas was used as fuel, and the sample quantity was small, and it had the function of flameout protection.
YUEFENG-
YueFeng FSP6633 Flame Spectrophotometer Test Potassium/Sodium/Barium
$ 2558.00 -
JINGQI FP640 Flame photometer
$ 912.00 -
JINGHUA 721 visible spectrophotometer high performance grating, digital display
$ 301.00 -
YueFeng 754N Ultraviolet-visible spectrophoto-meter 195~ 1100nm
$ 817.00 -
YUEFENG FP6421 Flame photometer Li/Ca
$ 1439.00
Features
The appearance is small, exquisite and beautiful.
Dual-channel LED digital display 4-digit digital display per channel, clear readings.
Unique ignition gas circuit, push-button automatic ignition, fast and reliable ignition.
Potassium and sodium can be detected at the same time, and it has the detection function of lithium calcium.
Using silicon photocell detection, the measurement results are accurate and stable.
Small amount of sample, high sensitivity.
Use liquefied petroleum gas as fuel, easy to use.
With flameout protection function, safe and reliable performance
FP flame photometer element parameter table
| element | Measuring range | linearity error | detection limit |
| Lithium | 0~15mmol/L | ≤0.02 | ≤0.015 |
| Ca calcium | 0~25mmol/L | ≤0.07 | ≤0.050 |
| Barium | 0~22mmol/L | ≤0.065 | ≤0.100 |
| Potassium K | 0.0~10.0mmol/L | ≤0.005 | ≤0.004 |
| Sodium | 0.0~200.0mmol/L | ≤0.03 | ≤0.008 |
YUEFENG FP6423 Flame photometerSpecifications
| LIST | VALUE |
|---|---|
| Ca Measurement range | 0-25mmol/L; |
| Stability measurement | The maximum deviation of the indication value in 15S is ≤ 3%, measured once per minute, measured 6 times in total, and the maximum deviation of the indication is ≤ 10% |
| Repeatability of Ca measurement | Relative standard deviation ≤ 3% |
| Ca measurement detection limit | ≤0.050 |
| Ca measurement Linearity | ≤0.07 |
| Ba Ba Measurement range | 0-22mmol/L |
| Ba Ba measurement Repeatability | Relative standard deviation ≤ 3% |
| Ba measurement detection limit | ≤0.100 |
| Barium Ba measurement Linearity | ≤0.065 |
YUEFENG FP6423 Flame photometer Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Working mechanism, common types and performance considerations of light stabilizers
- Application of Flame Atomic Absorption Spectrophotometry in Detection of Food Talc Powder
- ActiveGB/T 713.2-2023
- ActiveASTM D4185-23
- ActiveGB/T 3260.1-2024
- ActiveGB/T 693-2024
- ActiveGB/T 44215-2024
- ActiveSL/T 788.4-2019
- ActiveSL/T 788.5-2019
- ActiveSL/T 788-2019
- ActiveHJ 668-2013
- ActiveSL/T 788.1-2019
- ActiveGB/T 38216.5-2024
- ActiveGB/T 42513.7-2024
- ActiveGB/T 6730.89-2024
- ActiveHB 20056.1-2011
- ActiveYB/T 4217.1-2010
- ActiveYS/T 514.7-2009
- ActiveHJ 601-2011
- ActiveQX/T 216-2013
- Active 01010102-2006
- ActiveGB/T 15262-1994


FP6423
FP6429
FP6428
FP6427
FP6426
FP6425
FP6424
FP6422
FP6421
FP6455





