YOKE 3628AA Graphite furnace method Atomic absorption spectrophotometer Deuterium lamp Self-priming Background correction 8 lamp holder
The transverse heating graphite furnace technology is used to ensure uniform temperature, with 4/8 lamp stand automatic swirl/spin switching function, Wavelength range 185-900nm, and the visual injection system is equipped to facilitate the observation of the sample injection process.
Yoke-
YueFeng UV759 Ultraviolet-visible spectrophoto-meter Wavelength: 190m~ 1100nm
$ 1252.00 -
YueFeng 722S Single beam of light Visible Spectrophotometer
$ 332.00 -
JINGHUA 756CRT UV-Visible Spectrophotometer Light spectrum
$ 4423.00 -
YueFeng 723S Visible Spectrophotometer 325~ 1100nm without USB interface
$ 895.00 -
YUEFENG FP6428 Flame photometer Na/Ca
$ 1439.00
Features
Easy operation, fast response, low cost, unique anti-corrosion design, simple maintenance.
It has both deuterium lamp + self-priming full-band background correction technology, which can automatically fine-tune the lamp position to ensure the effect of buckle the background.
It is designed with a 4/8 stand with 360° automatic rotation switching. One lamp works, one lamp preheats, fully automatic adjustment, can automatically adjust the optimized working parameters and analysis conditions. It can be equipped with high-performance hollow cathode lamp work lamp.
Automatic control of wavelength scanning, automatic peak positioning.
The temperature of the graphite tube is uniform and uniform thanks to reliable laterally heated graphite furnace technology. Heating and temperature control mode: power control mode in the drying and ashing stage, and light control maximum power mode in the atomization stage. Heating method: slope heating, ladder Heating up, maximum power heating.
Equipped with graphite furnace injection visualization system: the built-in stable and reliable observation system can visually and clearly observe the injection process on the software It does not affect the performance of the host.
Both can be used with atomic absorption autosamplers for effective analysis.
Yoke 3628AA Graphite furnace atomic absorption spectrophotometerSpecifications
| LIST | VALUE |
|---|---|
| Instrument type | Single beam of light |
| Atomizer | Graphite furnace |
| Wavelength range | 185nm-900nm |
| Number of lamp holders | 8 lamp holder |
| Light spectrum Bandwidth | 0.1nm、0.2nm、0.4nm、0.7nm、1.4nm、2.0nm |
| Wavelength Precision | ±0.20nm |
| Wavelength Repeatability | ≤0.10nm |
| Baseline Stability | ±0.003A/30min ±0.005A/15min |
| Repeatability | RSD≤3% |
| detection limit | (Cd):≤1.0Pg ;(Cu):≤25Pg |
Yoke 3628AA Graphite furnace atomic absorption spectrophotometer Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1574-2016
- ActiveGB/T 6150.3-2023
- ActiveGB/T 6150.1-2023
- ActiveGB/T 26125-2011
- ActiveGB/T 19718-2005
- AbolishGB/T 13080-2004
- ActiveGB/T 26798-2011
- ActiveGB/T 26798-2011


3628AA