HANNA HI93703-11 Dual range turbidity Tester
Measurement range 0.00-50. 00FTU, 50-1000FTU, range automatic identification range conversion, resolution 0.01FTU (0.00-50. 00FTU), 1FNU (50-1000FTU), custom 890nm Infrared source, suitable for water quality monitoring, wastewater field and laboratory measurement use.
HANNA-
HANNA HI83749 Liquor turbidity and silica soda Tester
$ 1743.00 -
LEICI WZB-170 Turbidity Meter 850nm/200NTU
$ 483.00 -
JINGQI SS-200 Portable Suspended Solids Tester
$ 560.00 -
Yuefeng SGZ-1000IT Microcomputer Turbidity Meter 1000NTU/0.001
$ 783.00 -
Yuefeng SGZ-500I Microcomputer Turbidity Meter 500NTU/0.01
$ 497.00
Introduction
HI93703-11 portable dual-range Turbidimeter complies with ISO7027 measurement standards, and automatically converts measurements between low turbidity range (0.0â50.00FTU) and high turbidity range (50â1000FTU). The built-in excellent optical system, combined with a special large cuvette and a light-shielded measurement tank, allows for a higher light source pass rate and effectively reduces the impact of light source fluctuations and stray light.
AMCO-AEPA-1 special turbidity calibration set is non-toxic and harmless, has stable performance and can be stored and reused for a long time. Used to regularly calibrate the internal curve to ensure accurate instrument measurement. It is widely used in water quality monitoring, wastewater field and laboratory measurement.
Characteristics
Automatic range conversion and built-in turbidity standard calibration point to ensure measurement accuracy;
Unique GLP management function can automatically store the last calibration date;
Comply with ISO7027 turbidity standard, FTU is formazine turbidity unit;
199 sets of data storage and RS232 data interface facilitate data transmission, management and analysis;
Battery power display, timely reminder to replace the battery, automatic shutdown power saving mode.
Turbidity unit conversion
| Turbidity unit conversion | JTU | FTU(NTU/FNU) | ASBC | EBC | SiO2(mg/L) |
| JTU | 1 | 19 | / | / | 2.5 |
| FTU(NTU/FNU) | 0.053 | 1 | 0.057 | 4 | 0.13 |
| ASBC | 17.5 | 1 | 69 | 0.13 | |
| EBC | / | 0.25 | 0.014 | 1 | / |
| SiO2(mg/L) | / | 7.5 | / | / | 1 |
HANNA HI93703-11 Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.00-50.00FTU、50-1000FTU |
| range | Automatic identification range conversion |
| resolution | 0.01FTU(0.00-50.00FTU)、1FNU(50-1000FTU) |
| Measurement Accuracy | +/- 5% of reading or +/- 0.5 FTU, whichever is greater (@25 ℃) |
| Calibrated mode | Manual 3-point calibrating, built-in 3 calibrating points; 0FTU, 10FTU, 500FTU |
| Light source system | Silicon Photocell, photovoltaic cell, custom Infrared source, 890nm |
| unit conversion | 1FTU = 1NTU = 1FNU = 0.25ECB; 1mg / L = 1 |
| Measurement standard | Compliant with ISO7027 turbidity measurement standard |
| data management | RS232 Interface, 199 measurement Data storage |
| Automatic shutdown | 4X1.5V AA battery; will automatically shut down without any operation for 5 minutes |
| Miscellaneous indicators | 0 ℃-50 ℃; max 95% RH non-condensing; host size: 220x82x66mm, Weight 510g |
HANNA HI93703-11 Turbidity Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.