HANNA HI6421P dissolved oxygen table meter
Measurement range 0.00 to 50.00 mg/L (ppm), versatile, can cover a variety of dissolved oxygen, and built-in thermistor temperature sensor to compensate for temperature changes.
HANNA-
QIWEI JPB-70A Pen Oxygen Dissolution Meter
$ 169.00 -
Ordinary ORPscan10 pen ORP meter with platinum ORP electrode
$ 156.00 -
Ammonia electrode filler, 480 ml
$ 130.00 -
LEICI copper ion electrode calibrating solution, suitable for copper ion composite electrode
$ 106.00 -
Bante904P-UK portable multiparameter Water Quality Meter conductivity dissolved oxygen
$ 607.00
Introduction
The HI6421P is a streamlined benchtop meter with a large touch screen display, consisting of an instrument housing and an integrated module, designed for fresh and salt water measurements of dissolved oxygen.
HI6421P includes HI764833 polarographic probe. Small and versatile, this probe covers a wide range of dissolved oxygen and has a built-in thermistor temperature sensor to compensate for temperature changes. Slim design facilitates measurements in test tubes and Biological Oxygen Demand (BOD) bottles.
This rugged probe features a platinum cathode and Ag/AgCl anode assembly. The readings are accurate and the response time is fast, independent of flow rate. The probe is equipped with a durable PTFE, oxygen-permeable screw-on membrane cap. The cap is filled with electrolyte and can be easily installed on the probe.
Concentration measurements are automatically compensated for air pressure, temperature and salinity. Barometric pressure and temperature are automatically measured and compensated. Salinity is automatically compensated by manually setting the salinity concentration of the water being measured.
Other features include built-in methods and calculations for measuring BOD (Biological Oxygen Demand), OUR (Oxygen Uptake Rate), and SOUR (Specific Oxygen Renewal Rate).
Pressure compensation is done automatically (built-in barometer) or the user can choose to enter the required value manually. Pressure is displayed in user-configurable units: mmHg, mbar, kPa, inchesHg, PSI, atmosphere.
Features
User interface 7-inch capacitive touch screen with multi-touch support; capacitive touch screen, home and system menu keys; user-friendly icons and symbols allow the user to easily navigate and explain instrument functions; the user can navigate between five different views choose:
Simple GLP with calibration information; full GLP with electrode status and calibration point details; interactive graphs that update in real time; tabular data with date, time, and comments.
One or two point calibration at 0% and/or 100% saturation; single point manual calibration in mg/L or % saturation using reference method; non-volatile memory saves data and settings.
Measures %Sat, mg/L, ppm (DO); mg/L, ppm (BOD); mg/L (OUR); ppm, mg/L (SOUR); Application-specific profiles allow fast direct measurements, No need to update sensors and system settings.
Data log collection (with time and date stamp) of at least 1,000,000 data points; Logging type: manual, automatic, automatic hold; Example IDs for manual and automatic hold data connection features and services; Transfer logged data to USB thumb Drive; includes log files of measurement and calibration data (as .csv files); FTP and email for exporting logs over Ethernet and Wi-Fi connections; USB Type A for USB sticks, keyboards, and printers; Type C USB, used for U disk and PC connection.
HANNA HI6421P Dissolved oxygen table meterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range -DO dissolved oxygen (HI764113 fluorescence probe) | 0.00 to 50.00 mg/L (ppm) concentration; 0.0 to 500.0% saturation |
| Resolution DO dissolved oxygen (HI764113 fluorescence probe) | 0.01 mg/L (ppm); 0.1% saturation |
| Measurement Accuracy -DO dissolved oxygen (HI764113 fluorescence probe) | +/- 1.5% or +/- 0.01 mg/L (ppm) of reading, whichever is greater (0.00-20 mg/L); +/- 5% of reading (20.00-50 mg/L); +/- 1.5% or +/- 0.1% of reading, whichever is greater (0.0 - 200.0% saturation); +/- 5% of reading (200.0 - 500.0% saturation) |
| Measurement range -DO dissolved oxygen (HI764833 Polarography probe) | 0.00 to 90.00 mg/L (ppm) concentration; 0.0 to 600.0% saturation |
| Resolution DO dissolved oxygen (HI764833 Polarography probe) | 0.01 mg/L (ppm); 0.1% saturation |
| Measurement Accuracy -DO dissolved oxygen (HI764833 Polarography probe) | +/- 1.5% of reading +/- 0.1 mg/L (ppm), least significant bit |
| Measurement range - atmospheric pressure | 450 - 850 mmHg;600 - 1133 mBar;60 - 133 kPa;17 - 33 inHg;8.7 - 16.4 psi;0.592 - 1.118 atm |
| Resolution - Atmospheric Pressure | 1 mmHg;1 mBar;1 kPa;1inHg;0.1psi;0.001atm |
| Measurement Accuracy - atmospheric pressure | Calibrated point +/- 3 mmHg within 15%; +/- 3mmHg +/- 1 least significant digit |
| Measurement range - temperature | -20.0 to 120.0˚C |
| Resolution - Temperature | 0.1 °C |
| Measurement Accuracy - temperature | ±0.2 °C |
| Calibrating point -DO dissolved oxygen calibrating | DO fluorescence method: Automatic calibration of one or two points at 100% (8.26 mg/L) and 0% (0 mg/L), single point manual, using user-entered saturation% or mg/L values. DO Polarography: Automatic two-point/user standard single point. |
| -DO dissolved oxygen calibrated | 0 - 100% saturation |
| -DO dissolve oxygen calibrate | Turn off function; Daily: 0 minutes to 23 hours 59 minutes; Period: 1 minute to 500 days, 23 hours 59 minutes |
| Temperature compensation | Automatic compensation or manual |
| Power Supply | DC Adapter 100-240AC, 24 VDC 2.5A |
| Operating Environment | 0 - 50.0 °C |
| Size/Weight | 205 x 160 x 77mm / ≈1.2kg |
HANNA HI6421P Dissolved oxygen table meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI6421P