HANNA HI83749 Liquor turbidity and silica soda Tester
Measurement range 0.00 to 1200NTU, Measurement accuracy +/- 2% + 0.05NTU@25 ℃/77 ° F, turbidity measurement, USB-RS232 Dual Interface, 200 Data storage, good data management.
HANNAIntroduction
HI83749 wine turbidity and silica bentonite meter is specially designed for measuring wine turbidity. This Turbidity Meter is based on a reliable optical system that ensures accurate results, ensures long-term stability, and reduces stray light and color interference to low levels. Changes in lamp intensity are also compensated for. The 25mm round reaction cup composed of special optical glass ensures the repeatability of turbidity measurements. Ensures the stability of protein before bottling high-quality wines. Measures turbidity of samples in the range 0.00 to 1200 NTU, compliant with USEPA standards.
Preventing protein haze or precipitation in bottled white wines is a common concern and wines often need to be stabilized before bottling. One commonly used stabilizer is bentonite clay. Bentonite is a volcanic clay-type fining agent (such as kaolin) that can be used as a wine stabilizer. It improves the clarity of wine, but it also has negative effects because of the formation of lees, the reduction of tannins and color. Because different types and qualities of bentonite clay have different protein removal capabilities, it is important to conduct laboratory experiments using bentonite clays from the same batch and moisture level.
Winemakers can use the H183749 Turbidity Meter to determine the initial turbidity of unrefined wine. After taking the turbidity reading, add the previously prepared H183749-20 Bentocheck solution to the wine sample. Take a second turbidity measurement. A wine is considered stable if the second turbidity reading is less than the initial turbidity reading plus 2 NTU. Otherwise, a fining test can be performed to determine the amount of bentonite that must be added to stabilize the wine.
Characteristics
Wine turbidity-silica bentonite measurement, automatic range conversion, large screen display;
Average measurement mode (AVG): average of multiple readings to ensure accuracy;
USEPA standard and Standard Method 2130B method;
GLP management function, query settings, calibration, time and other information;
Manual calibration, built-in standard calibration points: <0.1, 15, 100, 500 NTU;
USB-RS232 dual data interface, 200 sets of data storage, good data management.
HANNA HI83749 Liquor turbidity and silica soda TesterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.00 to 9.99、10.0 to 99.9、100 to 1200NTU |
| resolution | 0.01NTU (≤9.99NTU)、0.1NTU(≤99.9 NTU)、1NTU(≤1200NTU) |
| Measurement Accuracy | Reading +/- 2% + 0.05NTU@25 ℃/77 ° F |
| Measurement Repeatability | +/- 1% of the reading or 0.02 NTU, whichever is greater |
| minimum detection limit | <0.05NTU |
| Measuring method | Turbidity assay in accordance with USEPA Method 180.1 and Standard 2130B |
| Calibrated mode | Manual calibration, built-in standard calibrating points: < 0.1, 15, 100, 500NTU |
| Optical inspection system | Custom Dedicated Receiver & Light source System |
| data management | USB-RS232 Dual Interface, 200 sets of measurement Data storage |
| Power mode | 4X1.5VAA battery; 15 minutes without any operation, it will automatically shut down. |
| Operating Environment | 0 to 50 ℃ (32 to 122 ° F), RH max 95%, non-condensing |
| Size Weight | Host size: 224x87x77mm Host Weight: 512g |
HANNA HI83749 Liquor turbidity and silica soda Tester Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI83749