MODERNER QCJ 0.5m film impact test, to detect the impact resistance of coating film
The MODERNER QCJ 0.5m paint film impact test device is designed with reference to the GB/T1732-93 standard. Impact is formed on the sample paint film by using a heavy hammer falling from a specific height. The impact resistance of the paint film is determined by observing the damage of the paint film.
Moderner-
JINGKELIAN QCJ-50 Lacquer Film Impact Height 0~50cm
$ 231.00 -
CHINA BLD-CJ21 Impact Tester Plastic, Ceramic, Acrylic fiberglass
$ 354.00 -
JINGKELIAN QJL Impact Tester film impact test instrument 120cm GB/T1723 ASTM D2794/G14
$ 815.00 -
SHUCHANG SC-JZL Simply Supported Beam Impact Tester Non-metallic Material Impact performance under dynamic load
$ 1097.00 -
CHENCHI MLB-01 Dart impact test instrument A, B Plastic film or sheet
$ 2905.00
The QCJ-II paint film impact Tester is designed with reference to the GB/T1732-93 standard. It uses a heavy hammer to drop from a specific height to impact the sample paint film. The impact resistance of the paint film is measured by observing the damage of the paint film. The impact resistance of a paint film is expressed in terms of the maximum height (centimeter value) that does not cause damage to the paint film.
Detail image

Advantages of use
| name | Film impact Tester | elastic impactor | Heavy impact Tester | |
| model | QCJ-II(0.5m) | QCJ-II-A(1m) | TCJ-II (0.5m) | ZJ |
| Impact method | Ball punch | spherical drop impact | Ball punch | |
| impact height | 0ï½50cm | 0ï½100cm | 0ï½100cm 0ï½40inch | 0ï½100cm 0ï½40inch |
| Drop weight | 1kg | 1kg/2Lbs | 1kg/300g | |
| additional quality | - | 1kg/2Lbs | 1kg | |
| Steel ball diameter | 8mm | 20mm/15.9mm | 12.7mm/15.9mm | |
| Mold base aperture | 15mm | 27mm/16.3mm | 16.3mm/31.75mm | |
| Dimensions | 252Ã140Ã840mm | 252Ã140Ã1340mm | 300Ã300Ã1400mm | 300Ã240Ã1400mm |
| weight | 14kg | 19kg | 18kg | |
Moderner QCJ Film impact testSpecifications
| LIST | VALUE |
|---|---|
| Impact mode | Spherical Clash Top Shot |
| Impact height | 0~100cm |
| Drop Weight Mass | 1000g |
| Striker Diameter | Φ8mm |
| die base aperture | Φ15mm |
| Standards | GB/T 1732-1993 |
| Dimensions | 252*140*1340mm |
| Net Weight | 14kg |
Moderner QCJ Film impact test Packing list
Impact x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJC/T 2570-2020
- ActiveSJ 20910A-2018
- Active 10302-2023
- Active 10310-2023
- ActiveGB/T 41899-2022
- ActiveGB/T 27806-2011
- ActiveGB/T 19250-2013
- ActiveJT/T 821.2-2011
- ActiveJT/T 821.1-2011
- ActiveASTM D2794-2024
- ReplacedQB/T 2025-1994
- ActiveASTM D 2794-2019
- AbolishJC 500-1992
- ActiveHG/T 2243-1991
- ActiveGB/T 9261-2008
- ActiveGB/T 9260-2008
- ActiveGB/T 6745-2008
- ActiveJB/T 5946-1991
- AbolishGB/T 1732-1993


QCJ