Surface roughness Tester KAIRDA NDT110 Metal and Non-metallic parts surface roughness testing instrument
Login -
KAIRDA NDT161 surface roughness Tester, contact asperity Tester
$ 1159.00 -
PRSR110 Roughness Gauge 4 measurement parameters Ra/Rz/Rt/Rq
Login -
Sand blasting shot peening Roughness Gauge AMITTARI AR-131A shot peening sand blasting, printing anti-corrosion and other industry tests
$ 428.00 -
Surface Finish Meter KAIRDA NDT120 Surface Finish Meter is suitable for a variety of surface finish inspections
Login
The PHASE II portable roughness Tester SRG-2000 is a pocket-sized, cost-effective instrument for measuring the surface roughness of workpieces and complies with the applicable standards. It can be used on different workpiece surfaces in the workshop, either horizontally or vertically.
The roughness values to be measured can be displayed sequentially on the large LCD screen at the touch of a button: Ra, Rz, Rms(Rq), Rt, and the sampling length can also be selected. The calibration method also allows the instrument to be calibrated on a standard sample that is carried with it. A beep is heard every time the measurement interface is prepared.
The easy-to-use SRG-2000 is capable of measuring roughness values on a wide range of surfaces: flat, cylindrical, cone, and grooved floors (grooves can be as long as they are 80x30 mm). It is suitable for quality inspection department, quality control department, processing workshop, assembly workshop and so on.
The SRG-2000 Surface Roughness Tester has a wide measurement range for measuring roughness values: Ra, Rz, Rms(Rq), Rt. The piezoelectric sensor with diamond stylus ensures that the measured values are stable and reliable, and the surface roughness parameter Ra values in accordance with ASME B46.1 are also in accordance with ISO standards. The Rz value complies with the relevant DIN standards.
Specifications
| Measurement parameters | Ra (ISO), Rz (DIN), Rms(Rq), Rt |
| Measuring range | Ra: 0.05-10.0μm / Rz 0.1-50μm Rq:0.05-10μm / Rt: 0.1-50μm |
| Display resolution | 0.01μm |
| Sampling length | 0.25mm/0.8mm/2.5mm |
| filter | RC simulation |
| Drive stroke length | 6mm |
| Sensor glide speed | 1.0mm/s |
| Indication error | ≤±12% |
| Sensor type | Piezoelectric sensors |
| Sensor stylus | Diamond, 5 μm tip radius |
| Operating ambient temperature | 0-40℃ |
| power supply | Built-in 3.7V lithium-ion rechargeable battery |
| charger | With a 9V DC power adapter, the charging time is about 3 hours |
| Sensor contact force | <50gf |
| Static force measurement of the sensor stylus | <1.6gf |
| Dimensions | 125 x 73 x 26mm |
| weight | 200g |
The PHASE II SRG-2000 comes standard with a main unit, a standard calibration template, a charger, an operating manual and an instrument case.
Surface Roughness Meter Measurement Guide The purpose of surface roughness is to be the result of some machining processes and their effects on the surface of the material involved.
The sliding surface roughness gauge is a common instrument in the workshop. The diamond stylus glides over the sample block and the piezoelectric sensor records the vertical movement. The recorded peaks and troughs are converted into established parameter values.
The roughness parameter varies depending on how the peak and trough values are reached. When measuring roughness, the commonly used parameter is "Ra", which is often defined as the arithmetic mean roughness. The Ra parameter is an easy-to-use, valid parameter, and there are many other parameters that are more specific and effective depending on the application requirements. It is with these parameters that we are able to define the surface roughness.
Now, in order to detect Ra parameter values, a portable hand-held surface roughness Tester is used, which is not only inexpensive and economical, but also digitally displayed and easy to operate. The surface roughness Tester is a required instrument for those factories that have Ra value testing requirements.
PhaseII Surface roughness meterSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital explicit |
| Measurement parameters | Ra、Rz、Rq、Rt |
| Measurement range | Ra:0.05~10.0μm/Rz 0.1~50μm Rq:0.05~10μm/Rt:0.1~50μm |
| Resolution | 0.01μm |
| Error of indication | ≤±12% |
| Sampling length | 0.25mm|0.8mm|2.5mm |
| Sensors - Materials | Piezoelectric Sensors, Diamond, 5 μm Tip Radius |
| Sensors - Force Measurement | 16mN |
| Stroke length | 6mm |
| filter | RC simulation |
| Power Supply | Built-in 3.7V lithium-ion rechargeable battery, with 9V DC power adapter, Charging time is about 3 hours |
| Dimensions | 125*73*26mm |
| Product Weight | 200g |
| Applicable standards | ASME B46.1 |
| Sensors coasting speed | 1.0mm/s |
| Operating temperature | 0-40℃ |
PhaseII Surface roughness meter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Surface Roughness and Assessment Methods of Surface Roughness
- Measurement Principle of PhaseII PTG Coating Thickness Gauge

PhaseII