UV1901PCS Ultraviolet-visible spectrophoto-meter Dual beam of light Light spectrum bandwidth adjustable
The Light spectrum bandwidth of UV1901PCS Ultraviolet-visible spectrophoto-meter is adjustable between 0.5/1.0/2.0/3.0/5.0nm, using dual beam of light metering system, the Wavelength range of UV1901PCS is 190~1100nm, Wavelength Accuracy is ± 0.1nm or ± 0.3nm.
Yoke-
YueFeng FSP6620 Flame Spectrophotometer Test Potassium/Sodium
$ 2092.00 -
JINGHUA 721 visible spectrophotometer high performance grating, digital display
$ 301.00 -
JINGHUA 7600-1CRT Dual beam of light UV-Visible Spectrophotometer Standard computer/printer
$ 5667.00 -
YUEFENG FP6455 Five-element Flame photometer
$ 1967.00 -
JINGHUA 5cm Colorimetric dish, width 5cm
$ 110.00
Yoke UV1901PCS UV-Vis Spectrophotometer adopts a double-beam photometry system, which is a professional high-parameter Spectrophotometer .
Instrument function
Photometric measurement: It can measure the transmittance and absorbance at 1 to 6 wavelengths at the same time.
Spectrum measurement: scan the spectrum of transmittance, absorbance and energy within the Wavelength range, and perform various data processing such as peak and valley detection, derivative calculation, spectrum calculation, etc.
Quantitative measurement: single-wavelength, double-wavelength, three-wavelength and multi-wavelength measurement. 1~9 point working curve (1~4 times) regression.
Kinetic measurement: Time scanning of transmittance and absorbance at any set wavelength and various data calculations can be performed.
Data output: data files and parameter files can be accessed, and the measurement results are output in a standard and common data file format.
main feature
1. The newly designed excellent optical system and high-performance holographic blazed grating ensure the low stray light of the instrument.
2. Double-beam photometry system, with the design of a professional circuit measurement and control system. Make the instrument have a high degree of stability and extremely low noise.
3. Fully automatic control system and professional design concept ensure that the instrument has high reliability and high stability.
4. The sample chamber design with detachable structure is easy to replace different accessories to meet different analysis requirements.
5. The spacious and open light source room design makes it easier to replace the light source.
6. The key components are all imported devices, which ensures the high reliability of the instrument performance.
7. Chinese and English operating software developed under the Windows environment provides a wealth of unique analysis functions.
8. Automatic eight pool design, more powerful.
plan

Yoke UV1901PCS SpectrophotometerSpecifications
| LIST | VALUE |
|---|---|
| Optical inspection system | Double beam of light, CT type optical path; 1200 lines/mm laser holographic Diffraction grating |
| Light spectrum bandwidth | 0.5nm1nm3nm5nm () |
| Wavelength range | 190~1100nm |
| Wavelength Accuracy | ± 0.1Nm (D2 656.1nm), ± 0.3nm full band |
| Wavelength Repeatability | ≤0.1nm |
| Photometric range | 0~200%T、-4~4A |
| Photometric Accuracy | ±0.002A(0~0.5A)、±0.004A(0.5~1A)、±0.2 %T (0~100 %T) |
| Luminosity, sexual repeability | ±0.001A(0~0.5A);±0.002A(0.5~1A);±0.1%T(0~100%T) |
| stray light | ≤ 0.02%T |
| Noise level | ±0.0004A |
| Stability | ±0.0004A@500nm |
| Baseline flatness | ±0.0004A |
| Data Interface | 320 × 240 graphic display LCD, optional USB2.0 printer and/or U disk Data output, USB connection to upper-layer software |
| light source | Tungsten lamp, deuterium lamp |
| Dimensions | 670*560*260mm |
| Weight | 26kg |
Yoke UV1901PCS Spectrophotometer Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Calibration of Spectrophotometer s
- Spectrophotometric testing
- Did you know that the maturity of fruits and vegetables can be quantified?
- Why is testing of children's clothing and accessories important?
- Color Measurement Challenges Faced by Manufacturers in the Metals Industry
- Which Spectrophotometer is widely used in the metal industry?
- Liquid color difference detection solution
- How to detect the color difference of fluorescent color-changing materials?
- Detection of nicotine content by Spectrophotometer
- Differences between visible, ultraviolet-visible, infrared, fluorescent and atomic absorption Spectrophotometer s
- ActiveJJF 1641-2017
- ActiveJG/T 235-2014
- ActiveJY/T 0570-2020
- ActiveGB/T 15503-1995
- AbolishGB/T 10656-2008
- ActiveGB/T 34323-2017
- ActiveGB/T 11220.1-1989
- AbolishHJ/T 201-2005
- ActiveGB/T 27594-2011
- AbolishGB 24408-2009
- AbolishGB/T 1628.2-2000
- ActiveGB/T 1721-2008
- ActiveJB/T 6778-1993
- ActiveJB/T 6777-1993
- ActiveGB/T 26810-2011
- AbolishGB/T 11175-2002
- ISO 6271-2-2004
- ISO 4630-2-2004
- ISO 3856-5-1984
- ISO 3856-2-1984


UV1901PCS