| screen display | monochrome |
| Scanning range | 0~6000mm steel longitudinal wave |
| operating frequency | 0.4MHz15MHz |
| Vertical linearity error | ≤4% |
| Horizontal linearity error | ≤0.2% |
| Gain | 110dB |
| Sensitivity margin | > 60dB (deep 200mm Φ2 flat bottom hole) |
| resolution | >32dB(5N20) |
| dynamic range | ≥30dB |
| channel | 100 groups |
| storage | 500 pairs of A sweeps |
| DAC/AVG Linear dispersion | Yes. |
| TCG Linear dispersion | without |
| B-scan | without |
| PC communication | Yes. |
| flaw detection video | Yes. |
| Pulse/Emission Intensity | Iradjustable |
| Noise level: | <8% |
| Sexual repeability emission frequency | 100~1000HZ |
| Sound speed range | 1000~9999m/s |
| Operating Mode | Straight Probe, Oblique Probe, Dual Crystal, Penetration |
| digital suppression | (0~80) %, does not affect linearity and gain |
| Operating Time | Continuous work for more than 8 hours (lithium battery) |
| Environment temperature | (-20~70) ℃ (reference value) |
| Relative Humidity | (20~95)% RH |
| Three-proof function | Yes. |
| Appearance size | 265 × 160 × 53mm (host) |
| Weight | 1150g |
| Standard configuration | Host, power adapter, straight probe, oblique probe, probe cable |
| Optional accessories | Communication software, data cable, flaw detection test block, computer |
Warranty days: 365 days
【After-sales service】
1. One year warranty, the warranty is responsible for the original factory;
2. Man-made damage or damage caused by improper use is not within the scope of free maintenance;
3. If the quality problem identified by the original factory does not affect the secondary sales, you can apply for a refund within 7 days and replace the goods within 15 days. Returns and exchanges due to selection errors will not be accepted, please confirm the specifications and models before purchasing.