EYESKY ES10B11-O2 Fixed Micro Oxygen Detector, Range 0~5000ppm
EYESKY ES10B11-O2 fixed trace oxygen Detector is an oxygen concentration Detector with instrument panel display and sound and light alarm, ES10B11-O2 test range is 0~5000ppm, zirconia detection principle.
EYESKY-
GUOYUGRA GY/VGD-200-CHCL3-G (0-50ppm) Trichloromethane Detector
$ 518.00 -
KORNO GT-903-SO2-Y sulfur dioxide Detector, range 0-10PPM
$ 452.00 -
BOSEAN BH-90M-NH3 Ammonia Gas Detector
$ 239.00 -
Empaer AASD-CH2O Lightning Series Handheld Formaldehyde Detector
$ 567.00 -
Baoshi'an BH-60-NH3 Fixed Ammonia Gas Detector 0~100ppm
$ 241.00
Introduction
Visionless ES10B11-O2 fixed micro oxygen Detector is a new one created by Visionless Technology on the basis of ES10AGas Detector, using original imported sensors and new ones32-bit low-power processor; Dashboard display boundarysurface, the value and the progress bar are displayed at the same time, which is beautiful and generous; Circuit adoption4 layers of wiring, against weak signals and anti-dryingDisturbance is stronger; Independent high-precision imported 16-bit AD chip and signal processing algorithm to measure data accuracyHigher and more stable;4~20mA, RS485, 200~1000Hz output signals can be selected, easy to accessAlarm controllers,PLC, DCS and other control systems; Explosion-proof structures are designed to be used in a variety of hazardous industriesLocation; The products are widely used in metallurgy, petroleum and petrochemical, municipal, chemical and other industries.









Features
◆ Imported high-performance sensor, high measurement accuracy, good repeatability and long service life;
◆ Independent 16-bit AD chip, 4-layer circuit board design, stronger ability to weak signal and anti-interference;
◆ The dashboard display interface is designed, the reading is beautiful and generous, and the humanized detail design is reflected;
◆ White, orange and red backlight design, normal and alarm status indication, clear at a glance;
◆ mg/m3, ppm, VOL, LEL can be selected;
◆ Embedded 32-bit ultra-low power processor, with independent signal processing algorithm, fast response speed and stability;
◆ Automatic protection function against high-concentration gas impact, with factory reset to prevent misoperation;
◆ The instrument is equipped with infrared remote control, which can be operated by remote control, without opening the cover, which is simple and convenient;
◆ Three-wire 4~20mA, RS485, 200~1000HZ signal output optional, relay output, data recovery, data storage and other functions;
◆ Two cable inlets, convenient for on-site installation;
◆ Independent air chamber structure, easy sensor replacement, no need for on-site calibration;
◆ Very good mechanical design, the air chamber is made of high-strength aluminum profile of military quality, wear-resistant and corrosion-resistant, suitable for complex and harsh industrial environments, reasonable and scientific air chamber design, to ensure the accuracy of real-time monitoring of the sensor;
◆ The explosion-proof grade is Exd II CT6, which is certified by the National Explosion-proof Electrical Inspection Center.
EYESKY ES10B11-O2 Fixed micro oxygen DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | Oxygen O2 |
| Sensors principle | principle of zirconia |
| Sampling method | Diffusion, circulation |
| O2-range | 0~5000PPm |
| O2- resolution | 0.01PPm |
| O2- detection Accuracy | ±3%F.S. |
| Operation mode | Infrared remote control for remote and close operation, easy to set up |
| Repeatability | ≤±1% |
| Zero drift | ≤ +/- 1% (F. S/year) |
| Response time | T90≤20s |
| recovery time | ≤20s |
| Explosion-proof sign | Exd Ⅱ CT6 |
| Protection level | IP66 |
| Output signal | Users can according to the actual site environment requirements, up to 2000 meters (single core 1mm2 Shielding cable) three-wire system 4-20mA current signal output, can be connected to the alarm Controller, PLC, DCS and other Control system (standard configuration) |
| main material | Shell: ADC12 aluminum alloy, strong, wear-resistant and corrosion-resistant (optional 316 stainless steel shell) Air chamber: high-strength wear-resistant and corrosion-resistant Aluminum profile, durable (optional 316 stainless steel air chamber) |
| Installation method | Wall-mounted, pipeline type |
| Operating temperature | -30~60℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Environmental humidity | 10%~95%RH |
| Power Supply | 24VDC (Normal Operating Voltage range 12~ 30VDC) |
| power consumption | 1.5W |
| Operating Pressure | ≤200Kpa |
| Dimension | 180*140*92mm |
| Weight | About 1.6Kg |
| execution standard | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
EYESKY ES10B11-O2 Fixed micro oxygen Detector Packing list
Host x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Analysis of Proportional Gas Concentration in Welding Process
- Why detect oxygen concentration? What should I pay attention to when using an oxygen Detector?
- Types of Gas Sensors Used in Safety


ES10B11-O2