      Leeb leeb510 Ultrasonic Flaw Detector
      10800.0 RMB
      ChinaChina
      Detail
      Ipre UF200 Ultrasonic Flaw Detector
      11300.0 RMB
      ChinaChina
      Detail
      Model comparison
      Principle UT Ultrasound UT Ultrasound
      Parameter comparison
      Scanning range 0~6000mm
      grade 2.5,5,10,20, 30,40,50,60,70,80,90,100,150,200, 250, 300, 350, 400, 450, 500,600,700,800,900,1000,2000,3000,4000,5000,6000。-20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600, 700,800,900,1000,1500,2000,2500,3000,3400。
      Scanning range adjustment step 0.1mm(2.5 mm~99.9mm),1mm(100mm~6000mm)
      Pulse shift -20~+3400 μs
      grade 2.5,5,10,20, 30,40,50,60,70,80,90,100,150,200, 250, 300, 350, 400, 450, 500,600,700,800,900,1000,2000,3000,4000,5000,6000。-20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600, 700,800,900,1000,1500,2000,2500,3000,3400。
      Pulse shift adjustment step distance 0.1(-20μs~999.9μs),1(1000μs~3400μs)
      Probe zero 0.0~99.99μs
      Probe zero point adjustment step 0.01
      Speed of sound 1000~15000m/s
      Fixed Speed of sound 2260,2730,3080,3230,4700,5900,6300
      Speed of sound adjustment step 1
      Operating Mode Single probe (receiving and sending), double probe (one receiving and one sending), transmission (transmission probe)
      Frequency range Broadband 0.5 - 15MHz
      Gain adjustment 0~110dB
      Gain Adjustment Adjustment Step 0.0,0.1,0.5,1,2,6,12
      linear inhibition Screen height 0%~ 80%, step distance: 1%
      Vertical Linearity Vertical Linearity not more than 4%
      Horizontal Linearity Within the scanning range, no more than 0.2%
      Flaw detection sensitivity margin ≥60dB
      Dynamic range ≥32dB >40dB
      Alarm function Incoming wave alarm, loss wave alarm
      Display High luminance color flat panel display
      A-Scan display area Full screen or partial; A-Scan display freeze and thaw; A-Scan fill
      Flaw detection channel 100 pieces
      Data storage 500 A-Scan graphics
      Communication interface standard with PC USB
      Measurement unit Mm/inch
      Power adapter Input 100V~ 240V/50Hz~ 60Hz; Output 9V/1.5A
      battery Lithium (Li) battery 4 × 3.6V 4800mAh
      Operating temperature -10~50℃
      Operating humidity 20%~90%RH
      Interface type BNC
      Dimensions 260×140×50mm
      Weight 1.0kg
      optional Probe, standard test block, PC communication software, BNC cable, coupling agent