      HG/T 3862-2006 "Test Method for Yellow Index of Plastics" specifies the method for yellow index testing of colorless transparent, translucent and nearly white opaque plastics. This standard applies to plate, sheet, film and powder, granular specimens, but not to plastics containing fluorescent substances. The yellow index YI is characterized by a reference value of oxidation mg under the International Commission on Illumination (CIE) standard C Light source and can be used to evaluate the mass and aging of plastics. The yellow index of transmission of transparent plastics is affected by thickness and can only be compared at the same thickness. A positive value of yellow index measured by this method indicates that the material is yellow, and a negative value indicates that it is blue.

      This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
      Status Active
      CCS ICS
      Release Date Implementation Date
      98 in total
      filter
      Featured Hot Price Time
      3NH DS360 portable Colorimeter MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mm
      $4112.00 SE
      3NH DS360 portable Colorimeter MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mm
      Dual diameter: MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mmChromatic value: MAV/SCI, Delta E * ab within 0.05 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s)MAV/SCI, Delta E * ab within 0.3 (BCRA series ⅱ 12 color plate measurement average)
      +Compare
      3NH PS2070 handheld Colorimeter φ 4mm/φ 8mm flat tip four calibers
      $1450.00 SE
      3NH PS2070 handheld Colorimeter φ 4mm/φ 8mm flat tip four calibers
      Four caliber: MAV: Should 8mm/Should 10mm (platform + tip nozzle measurement diameter); SAV: Should 4mm/Should 5mm (platform + tip nozzle measurement diameter)Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)ΔE*ab<0.2(MAV/SCI)
      +Compare
      3NH PS2060 handheld Colorimeter φ 4mm/φ 8mm/: 1x3mm three caliber
      $1293.00 SE
      3NH PS2060 handheld Colorimeter φ 4mm/φ 8mm/: 1x3mm three caliber
      Three caliber: MAV: Should 8mm/Should 10mm (platform measurement diameter); SAV: Should 4mm/Should 5mm (platform measurement diameter); SSAV: 1x3mm (pointed nozzle measurement diameter);Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.03 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)ΔE*ab<0.3(MAV/SCI)
      +Compare
      3NH TS8450 Portable reflective film Colorimeter φ 4mm caliber
      3NH TS8450 Portable reflective film Colorimeter φ 4mm caliber
      F4mm / F5mmChromatic value: MAV/SCI, ΔE * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s)ΔE * from < 0.15 (MAV / SCI)
      +Compare
      IWAVE SA23 Colorimeter φ 4mm Single Caliber, Entry Edition
      $2546.00 SE
      IWAVE SA23 Colorimeter φ 4mm Single Caliber, Entry Edition
      Φ4mmDelta E * ab ≤ 0.4 (the average measurement value of 0026 12 color blocks)
      +Compare
      IWAVE SY3020 Colorimeter, 4mm Measurement
      $695.00 SE
      IWAVE SY3020 Colorimeter, 4mm Measurement
      Φ4mmDelta E * ab ≤ 0.4 (the average measurement value of 0026 12 color blocks)
      +Compare
      Kutai MS3008 Automotive Colorimeter 8 Measurement angles
      Kutai MS3008 Automotive Colorimeter 8 Measurement angles
      F12mm0.18ΔE * 00 (BCRA series Ⅱ 12 color plate measurement average)
      +Compare
      3NH DS360 portable Colorimeter φ 8mm/φ 10mm
      $2891.00 SE
      3NH DS360 portable Colorimeter φ 8mm/φ 10mm
      Single diameter: phi 8mm/phi 10mmChromatic value: MAV/SCI, Delta E * ab within 0.06 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s)MAV/SCI, Delta E * ab within 0.3 (BCRA series ⅱ 12 color plate measurement average)
      +Compare
      IWAVE SA26 Colorimeter φ 8mm/φ 4mm Dual Caliber, Professional Edition
      $4739.00 SE
      IWAVE SA26 Colorimeter φ 8mm/φ 4mm Dual Caliber, Professional Edition
      Dual diameter φ 8mm/φ 4mm can be switchedDelta E * ab ≤ 0.4 (the average measurement value of 0026 12 color blocks)
      +Compare
      IWAVE SY3020 Colorimeter, Measurement
      $695.00 SE
      IWAVE SY3020 Colorimeter, Measurement
      Φ8mmDelta E * ab ≤ 0.4 (the average measurement value of 0026 12 color blocks)
      +Compare
      IWAVE WS4500 Colorimeter
      $2421.00 SE
      IWAVE WS4500 Colorimeter
      Light spot 8mm (diameter φ 11mm)/light spot 4mm (diameter φ 6mm) optionalLight spot 8mm (diameter φ 11mm)/light spot 4mm (diameter φ 6mm) optionalDelta E < 0.3 (RAL12 color block)
      +Compare