Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result >

      STIP-scan

      131 results
      Featured Hot Price Time
      TONGAO TR-103H Nitrite Analyzer 0.002mg/L-1mg/L
      $792.00 SE
      TONGAO TR-103H Nitrite Analyzer 0.002mg/L-1mg/L
      nitrite0~1Mg/L (measured in sections)
      Detect the nitrite content, the range is 0.002mg/L-1mg/L (segmented determination), no digestion is required, and the digestion Colorimetric integrated detection is used, which conforms to the GB7493-87 standard.
      Compare
      HANNA HI97105 multiparameter photometer for seawater
      $745.00 SE
      HANNA HI97105 multiparameter photometer for seawater
      LED Light source, bandpass filter wavelength 525 & 610 nm; Bandwidth 8nm; Wavelength Accuracy +/- 1.0 nm, can be used for the measurement of pH acid alkalinity, calcium ions, nitrate, phosphoric acid and other parameters, is a powerful and widely used water quality analysis instrument.
      Compare
      HANNA HI93726-01 Photometer Nickel reagent 100 times
      $524.00 SE
      HANNA HI93726-01 Photometer Nickel reagent 100 times
      Reagent name Nickel, range 0.00 to 7.00 g/L (as Ni), 100 times.
      Compare
      TONGAO TR-107H phosphoric acid Tester, ammonium molybdate Spectrophotometric method, spec-trophotometry
      $792.00 SE
      TONGAO TR-107H phosphoric acid Tester, ammonium molybdate Spectrophotometric method, spec-trophotometry
      Phosphoric acid salt0~20Mg/L (measured in sections)
      Detect the content of phosphoric acid salt, the range is 0.02mg/L-20mg/L (segmented determination), without digestion, using digestion Colorimetric integrated detection, in line with HJ 670-2013 standard.
      Compare
      HANNA HI97751 Sulfate Portable Photometer
      $613.00 SE
      HANNA HI97751 Sulfate Portable Photometer
      0 to 150 mg/L (e.g. SO42-)
      Measurement range 0 to 150 mg/L (e.g. SO42-), resolution 1 mg/L, accuracy @25 ℃: +/- 5 mg/L +/- 3%, commonly used in water quality monitoring, environment protection and industrial production.
      Compare
      HANNA HI97770 Silica/Silicon [HR] Portable Photometer
      $613.00 SE
      HANNA HI97770 Silica/Silicon [HR] Portable Photometer
      Measurement range 0 to 200 mg/L (as SiO2), resolution 1 mg/L, accuracy @25 ℃: +/- 1 mg/L +/- 5% of reading, widely used in water treatment, drinking water monitoring, environment protection and industrial process control.
      Compare
      DDKSIC PH100T Laboratory pH Meter Touch Screen pH/mV (ORP electrode optional)/℃
      $619.00 SE
      DDKSIC PH100T Laboratory pH Meter Touch Screen pH/mV (ORP electrode optional)/℃
      pH, mV (ORP electrode optional), ℃-2.000~20.000ph
      -2.000~20.000pH, accuracy +/- 0.002pH, Intelligent Operating system, with electrode management, data management, parameter setting, data locking, Automatic calibration and other functions.
      Compare
      TONGAO TR-151H Portable Chlorine Dioxide Tester
      $792.00 SE
      TONGAO TR-151H Portable Chlorine Dioxide Tester
      chlorine dioxide0~10Mg/L (measured in sections)
      Detect the content of chlorine dioxide, the range is 0.05mg/L-10mg/L (measured in sections), no digestion is required, the detection time is 1 to 2 minutes, and the digestion Colorimetric integrated detection is used.
      Compare
      NOBOTECH ZS-680 Flow Online Suspension Meter 0-500NTU
      $757.00 SE
      NOBOTECH ZS-680 Flow Online Suspension Meter 0-500NTU
      0~200Mg/L, range can be customized
      Range 0-200mg/L, built-in bubble elimination system, with water storage function, invisible near monochrome Infrared source, two-point correction, imported core accessories, can be customized range.
      Compare
      HANNA HI97762 ULR residual chlorine [free chlorine] Portable Photometer
      $613.00 SE
      HANNA HI97762 ULR residual chlorine [free chlorine] Portable Photometer
      Residual chlorine Measurement range 0.00 to 10.00 mg/L (as Cl2), resolution 0.01 mg/L, accuracy reading of +/- 0.03 mg/L +/- 3%, widely used in water treatment, swimming pool monitoring, drinking water mass detection, etc.
      Compare
      TONGAO TR-116H Manganese meter, water quality heavy metals Detector
      $792.00 SE
      TONGAO TR-116H Manganese meter, water quality heavy metals Detector
      manganese0~5Mg/L (measured in sections)
      Detection of manganese content, the range is 0.04mg/L-5mg/L (measured in sections), no digestion is required, the detection time is 10 to 15 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the GB11906-89 standard.
      Compare
      TONGAO TR-136H Water Quality Volatile Phenol Tester
      $792.00 SE
      TONGAO TR-136H Water Quality Volatile Phenol Tester
      volatile phenol0~10Mg/L (measured in sections)
      Detect the content of volatile phenols, the range is 0.1mg/L-10mg/L (measured in sections), no digestion is required, the detection time is 10 to 15 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the HJ503-2009 standard.
      Compare
      LEICI DGB-403F Portable residual chlorine/total chlorine/chlorine dioxide Tester
      $616.00 SE
      LEICI DGB-403F Portable residual chlorine/total chlorine/chlorine dioxide Tester
      Using DPD Colorimetry, it can accurately measure residual chlorine, total chlorine and chlorine dioxide in water, support single and multi-point calibrating, Data storage, USB communication and waterproof and dustproof functions, suitable for drinking water, medical wastewater, swimming pool water and other water quality Determination of residual chlorine, total chlorine and chlorine dioxide.
      Compare
      HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer
      $613.00 SE
      HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer
      Residual chlorine measurement range: 0.00 to 5.00mg/L (asCl2), resolution: 0.01mg/L, accuracy: +/- 0.03mg/L +/- 3% of reading, total chlorine measurement range 0.00 to 5.00mg/L (asCl2), built-in reaction Timer to ensure consistent results between sample measurements and users.
      Compare
      DDKSIC DO10 portable color screen Dissolved Oxygen Meter (polarographic type) dissolved oxygen concentration/dissolved oxygen saturation/℃
      $572.00 SE
      DDKSIC DO10 portable color screen Dissolved Oxygen Meter (polarographic type) dissolved oxygen concentration/dissolved oxygen saturation/℃
      Dissolved oxygen concentration, dissolved oxygen saturation, ℃
      DO10 portable polarographic Dissolved Oxygen Meter, support temperature automatic compensation, pressure automatic compensation, salinity manual compensation, support full oxygen calibration, zero oxygen calibration.
      Compare
      HANNA HI97753 chlorides [CI] Portable Photometer
      $613.00 SE
      HANNA HI97753 chlorides [CI] Portable Photometer
      Measurement range 0.0 to 20.0 mg/L (e.g. Cl -), resolution 0.1 mg/L, accuracy @25 ℃: +/- +/- 6% of reading at 25 ℃, widely used in water treatment, environment monitoring, industrial production and other fields.
      Compare
      HANNA HI97742 2-in-1, Iron LR and Manganese LR Portable Photometer
      $613.00 SE
      HANNA HI97742 2-in-1, Iron LR and Manganese LR Portable Photometer
      Measurement range of iron 0.00 to 1.60 mg/L (as Mn), resolution 0.01 mg/L, Mn Measurement range 0 to 300 μg/L (as Mn), resolution 1 μg/L, commonly used in environment monitoring, wastewater treatment, drinking water mass detection and other fields.
      Compare
      TONGAO TR-740H Nickel meter, water quality heavy metals Detector
      $792.00 SE
      TONGAO TR-740H Nickel meter, water quality heavy metals Detector
      nickel0~4Mg/L (measured in sections)
      Detection of nickel content, the range is 0.1mg/L-4mg/L (segmented determination), no digestion is required, the detection time is 5 to 10 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the GB11910-89 standard.
      Compare
      HANNA HI97739 Fluoride HR Portable Photometer
      $613.00 SE
      HANNA HI97739 Fluoride HR Portable Photometer
      0.00-20.00mg/L
      Measurement range 0.00-20 mg/L, resolution 0.01mg/L, accuracy @25 ℃: +/- 3 %; +/- 0.5mg/L of reading, commonly used in drinking water monitoring, industrial production process control and other fields to ensure that the concentration of fluoride ions in water is within the safe range.
      Compare
      HANNA HI97769 Surfactant [SDBS] Portable Photometer
      $613.00 SE
      HANNA HI97769 Surfactant [SDBS] Portable Photometer
      Measurement range 0.00 to 3.50 mg/L (as SDBS), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.04 mg/L +/- 3% of reading, widely used in water treatment, environment monitoring, detergent production and detergent residue detection.
      Compare
      TONGAO TR-701H Water Quality Nitrate Nitrogen Tester
      $792.00 SE
      TONGAO TR-701H Water Quality Nitrate Nitrogen Tester
      nitrate nitrogen0~10Mg/L (measured in sections)
      Detection of nitrate nitrogen content, the range is 0.5mg/L-10mg/L (measured in sections), no digestion is required, the detection time is 10 to 15 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the standard of "Water Quality, Chromotropic Acid Spectrophotometry".
      Compare
      HANNA HI764080 Built-in temperature sensor Digital dissolved Oxygen electrode
      $850.00 SE
      HANNA HI764080 Built-in temperature sensor Digital dissolved Oxygen electrode
      0 to 300% oxygen saturation
      Measurement range 0 to 300% oxygen saturation, Operating temperature range 0 to 50 ℃, integrated temperature sensor and easily replaceable PTFE membrane cover, the ability to transfer information allows hot swapping of the probe without recalibrating.
      Compare
      HANNA HI97750 Potassium/potassium oxidation Portable Photometer
      $613.00 SE
      HANNA HI97750 Potassium/potassium oxidation Portable Photometer
      Measurement range 0.0 to 20.0 mg/L; 10 to 100 mg/L (as K), resolution 0.1 mg/L, accuracy @25 ℃: +/- 3 mg/L +/- 7% of reading, commonly used in soil and agricultural analysis to assess soil fertility and crop nutritional status, it can also be used to monitor oxidation potassium content in wastewater, etc.
      Compare
      HANNA HI97771 residual chlorine [free chlorine] -UHR total chlorine Portable Photometer
      $613.00 SE
      HANNA HI97771 residual chlorine [free chlorine] -UHR total chlorine Portable Photometer
      Residual chlorine Measurement range 0.00 to 5.00 mg/L (as Cl2), resolution 0.01 mg/L, total chlorine Measurement range 0to 500 mg/L (as Cl2), resolution 1 mg/L, using innovative Optical inspection system design, with good accuracy.
      Compare
      HANNA HI97720 calcium hardness Portable Photometer
      $613.00 SE
      HANNA HI97720 calcium hardness Portable Photometer
      Calcium hardness measurement range 0.00 to 2.70 mg/L (as CaCO3), resolution 0.01 mg/L, high quality Optical inspection filter, unique reference Detector to ensure measurement accuracy and accuracy.
      Compare
      HANNA HI97747 Copper [Cu, LR] Portable Waterproof Photometer
      $613.00 SE
      HANNA HI97747 Copper [Cu, LR] Portable Waterproof Photometer
      Measurement range 0.000 to 1.500 mg/L (as Cu2 +), resolution 0.001 mg/L, accuracy @25 ℃: +/- 0.010 mg/L +/- 5% of reading, commonly used in environment monitoring, wastewater treatment, drinking water mass detection and other fields.
      Compare
      HANNA HI97748 Manganese/potassiumhy permanganate [LR] Portable Photometer
      $613.00 SE
      HANNA HI97748 Manganese/potassiumhy permanganate [LR] Portable Photometer
      Measurement range 0 to 300 μg/L (as Mn), resolution 1 μg/L, accuracy @25 ℃: +/- 10 μg/L +/- 3% of reading, commonly used in environment monitoring, drinking water mass detection, industrial process control and other fields.
      Compare
      HANNA HI97749 Hexavalent Chromium/Chromate/Dichromate [LR] Portable Photometer
      $613.00 SE
      HANNA HI97749 Hexavalent Chromium/Chromate/Dichromate [LR] Portable Photometer
      Measurement range 0 to 300 μg/L (as Cr (VI)), resolution 1 μg/L, accuracy @25 ℃: +/- 10 μg/L +/- 4% of reading, commonly used in industrial wastewater treatment, environment monitoring and water quality control.
      Compare
      HANNA HI97746 Iron [LR] Portable Photometer
      $613.00 SE
      HANNA HI97746 Iron [LR] Portable Photometer
      Measurement range of iron 0.00 to 1.60 mg/L (as Mn), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.01 mg/L +/- 8% of reading, commonly used in environment monitoring, water quality control, industrial process control and other fields to ensure that the iron concentration in water is within the safe range and meets the requirements of relevant standards and regulations.
      Compare
      DDKSIC DO100T laboratory Dissolved Oxygen Meter (polarographic type) dissolved oxygen concentration/dissolved oxygen saturation/℃
      $643.00 SE
      DDKSIC DO100T laboratory Dissolved Oxygen Meter (polarographic type) dissolved oxygen concentration/dissolved oxygen saturation/℃
      Dissolved oxygen concentration, dissolved oxygen saturation, ℃
      0.00~20.00Mg/L, accuracy +/- 0.30mg/L, Intelligent Operating system, with electrode management, data management, parameter setting, data locking, Automatic calibration and other functions.
      Compare
      If you don't know how to choose "STIP-scan", please consult customer service.
      Focus on online sales of Lab Testing Instruments