$392.00
SE
Empaer AATL-CL2 Pathfinder Series Stationary Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, can control peripherals, full alarm reminder function

$225.00
SE
Empaer SPES-CH4 Lone Walker Series Handheld Methane concentration Detector
CH40~100%LEL
Detection gas type CH4, detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$471.00
SE
Empaer APEG-D-CL2 (4G) Volkswagen Series Stationary Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$236.00
SE
Empaer APEG-D-CH4 Volkswagen Series Stationary Methane Detector
CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias CH4, detection range 0~100% LEL, detection accuracy is better than the national standard accuracy, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$594.00
SE
Empaer AASD-SO2 Lightning Series Handheld Sulfur Dioxide Detector
SO20~100ppm
Gas name and alias SO2, detection range 0~100ppm, using mode diffusion type, use mode handheld, neck hanging type, automatic zero calibration automatic correction function, working Temperature & Moisture -40 ℃~ 55 ℃, storage temperature -10 ℃~ 30 ℃.

$414.00
SE
Empaer AATL-CL2 (Sound and Light Alarm) Pathfinder Series Fixed Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), sound and light alarm storage temperature -10 ℃~ 30 ℃,

$795.00
SE
Empaer AATL-CL2 (Pump Suction) Pathfinder Series Fixed Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$571.00
SE
Empaer SPES-SO2 series handheld sulfur dioxide concentration Detector
SO20~100ppm
Detection of gas type SO2, detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$582.00
SE
Empaer APEG-D-SO2 Volkswagen Series Stationary Sulfur Dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias SO2, detection range 0~100ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃, detection accuracy is better than the national standard accuracy, generally ≤ +/- 3% FS

$247.00
SE
Empaer AASD-CH4 Lightning Series Handheld Methane Detector
CH40~100%LEL
Gas name and alias CH4, detection range 0~100% LEL, error of indication ≤ national standard, Repeatability ≤ national standard, using mode diffusion type, working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃.

$727.00
SE
Empaer AATL-SO2 (4G) Pathfinder Series Stationary Sulfur Dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$616.00
SE
Empaer AATL-SO2 Pathfinder Series Stationary Sulfur Dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias SO2, detection range 0~100ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA

$347.00
SE
Empaer SPES-CL2 series handheld chlorine concentration Detector
CL20~50ppm
Detection gas type CL2, detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$673.00
SE
Empaer AATL-CH4 (Pump Suction) Pathfinder Series Fixed Methane Detector
CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CH4, detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$1019.00
SE
Empaer AATL-SO2 (Pump Suction) Pathfinder Series Stationary Sulfur Dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias SO2, detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation)

$359.00
SE
Empaer APEG-D-CL2 Volkswagen Series Stationary Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, automatic calibration zero automatic correction function, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$269.00
SE
Empaer AATL-CH4 Pathfinder Series Fixed Methane Detector
CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias CH4, detection range 0~100% LEL, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA

$292.00
SE
Empaer AATL-CH4 (Sound and Light Alarm) Pathfinder Series Fixed Methane Detector
CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CH4, detection range 0~100% LEL, sound and light alarm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$503.00
SE
Empaer AATL-CL2 (4G) Pathfinder Series Fixed Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$638.00
SE
Empaer AATL-SO2 (sound and light alarm) Pathfinder series fixed sulfur dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, please consult the customer service of the mall.
Gas name and alias SO2, detection range 0~100ppm, sound and light alarm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation)

$228.00
SE
Baoshi'an BH-90-HCN Hydrogen Cyanide Gas Detector 0~10ppm
ElectrochemistryMiscellaneous0 to 10 ppm (hydrogen cyanide HCN)DiffusionDiffusion

$228.00
SE
BH-90-C2H4O Ethylene oxide Gas Detector 0~100ppm
ElectrochemistryMiscellaneous0~100ppm (ethylene oxide C2H4O)DiffusionDiffusion

$240.00
SE
BOSEAN BH-90M-NO Nitric oxide Gas Detector
0~250ppm
Range 0-250ppm, resolution 1ppm, unit ppm, suitable for gas nitric oxide, using industrial grade Sensors and micro control technology, with fast Response, high accuracy measurement ability, stability and repeability.

$240.00
SE
BOSEAN BH-90M-NH3 Ammonia Gas Detector
0-100ppm
Range 0-100ppm, resolution 0.1/1 ppm, unit ppm, suitable for gas ammonia, alarm point can be manually set, different gas default alarm point is different.

$228.00
SE
BOSEAN BH-90-NO Portable Gas Alarm Instrument 0~250ppm
ElectrochemistryMiscellaneous0~250ppm(NO)DiffusionDiffusion

$259.00
SE
BH-60-Cl2 Fixed Chlorine Gas Detector with display + alarm
electrochemistryMiscellaneous

$259.00
SE
BH-60-SO2 Gas Detector with display + alarm 0~20ppm
electrochemistryMiscellaneous

If you don't know how to choose "Gas detector", please consult customer service.