Impact Tester TQC SP1890 meets ISO 6272-1 standard
The TQC Impact Tester SP1890 is a direct Impact type impact Tester. The maximum thickness of the test plate that can be tested by the SP1890 Impact Tester is 125mm. It is suitable for testing paints, Coatings and other industries. Impact performance
TQC sheen-
YONGLIDA TCJ Elastic Impact Tester 100cm ASTM D2794, ISO6272
$ 599.00 -
Falling ball impact test instrument, Dutch TQC SP1891 standard ISO 6272-1 and ASTM D2794
$ 4207.00 -
SHUCHANG ZM-JZL-5D Digital Display Simply Supported Beam Impact Tester
$ 1097.00 -
CHINA BLD-CJ21 Impact Tester Plastic, Ceramic, Acrylic fiberglass
$ 354.00 -
PUSHEN CJQ-II Film Impact 50cm/1000g GB/T 1732
$ 249.00
SP1890 Impact Testing Machine Overview
The Dutch TQC impact testing machine SP1890 is a direct impact type impact testing machine. It is suitable for testing the impact resistance of paint films in the paint, coating and other industries. The impact of the weight on the paint film will cause the paint film to deform, crack or fail from the test. The impact resistance performance of the paint film coating can be judged based on the conditions such as board peeling.
The SP1890 impact testing machine complies with the international standard ISO 6272-1, and the maximum test plate thickness that can be tested is 125mm.
SP1890 impact testing machine application standards
Comply with ISO 6272-1:2002, JIS K 5600-5-3:1989, EN 13523-5:2001 and other standards.
* The standards that meet the requirements depend on the type of impact testing machine, and other standards can be applied by changing the device combination.
SP1890 impact testing machine operation method
1) Check whether the SP1890 impact testing machine is placed horizontally, whether all components are installed correctly and a punch of appropriate diameter is selected.
2) Use the compression handle on the side to compress the test board.
3) Gently lower the weight onto the punch and adjust the guide tube. The 0 mark on the guide tube should be kept level with the bracket of the drop weight.
4) Make sure that the punch can be raised when the red button is pressed and the drop weight can slide freely on the pipe.
5) Adjust the height limit ring, and adjust the weight to the corresponding scale line in the conduit according to the height required for the test.
6) Raise the drop weight and lock it with the release clamp.
7) Raise the drop weight to the starting position and press the red button to release the test sample.
8) Check the test sample for coating cracking.
9) The test can be repeated according to experimental needs.
SP1890 impact testing machine display diagram


Functional structure comparison diagram of TQC series impact Tester
| serial number | Part Name | SP1880 | SP1890 | SP1891 | SP1895 |
| 1 | catheter | â | â | â | â |
| 2, 6, 13 | Base with built-in bubble level | â | â | â | â |
| 3 | 16.3mm die | â | â | ||
| 3 | 27.0mm die | â | â | ||
| 4 | 1kg weight | â | â | ||
| 5 | Heavy hammer | â | â | â | â |
| 7 | 15.9mm diameter punch | â | â | â | |
| 8 | 12.7mm diameter punch | â | |||
| 9 | lift release punch | â | |||
| 10,11,12 | height limit ring | â | â | â | â |
| 14,15,16 | V-notch vise with spring clamp | ||||
| 17 | weight | â | â |

Impact Tester functional structure diagram
TQC sheen SP1890 Impact test instrumentSpecifications
| LIST | VALUE |
|---|---|
| Drop Weight Mass | 1000g |
| Striker Diameter | Φ20mm |
| die base aperture | Φ27mm |
| Meet the standard | ISO 6272-1:2002、JIS K 5600-5-3:1989、EN 13523-5:2001 |
| Maximum test plate thickness | 125mm |
| height limit ring | Yes. |
| Bubble level | Built-in base |
TQC sheen SP1890 Impact test instrument Packing list
Base (including level) x1, duct x1, height limit ring x1, punch (20mm) x1, falling body (1KG) x1, mold (diameter 27mm) x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 002-2015
- ActiveSH/T 3022-2019
- Active 10302-2023
- ActiveASTM
- ActiveJT/T 821.1-2011
- ActiveDL/T 2308-2021
- ActiveJG/T 224-2007
- ActiveHG/T 5060-2016
- ActiveHG/T 4338-2012
- Active 0025-2018
- ActiveHG/T 5176-2017
- ActiveHG/T 5059-2016
- ActiveDB 44/T 1106-2012
- ActiveDB 44/T 1024-2012
- ActiveHG/T 5368-2018
- ActiveHG/T 4568-2013
- ActiveHG/T 4770-2014
- Active 2421-2022
- Active 2422-2022
- ActiveHG/T 4336-2012


SP1890
SP1895
SP1891
SP1880