      Home> Coating Thickness Gauge> ElektroPhysik> ElektroPhysik MiniTest 4500 Coating Thickness Gauge
      ElektroPhysik MiniTest 4500 Coating Thickness Gauge

      EPK MiniTest 4500 Coating Thickness Gauge can be grouped and calibrated with compensation/Bluetooth/sound and light alarm

      EPK MiniTest 4500 Coating Thickness Gauge is EPK's new Film thickness meter, used to replace the MiniTest 4100 series, MiniTest 4500 has 200W storage, can be grouped, comes with a variety of calibrated with compensation, USB, Bluetooth, can also sound and light alarm, probe need to be purchased separately.

      Brand
      SKU: NB016221
      Germany ElektroPhysik
      VS
      Genuinegoods
      • ElektroPhysik MiniTest 4500 Coating Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      MiniTest 4500
      Coating Thickness Gauge

      MiniTest 2500 andMiniTest 4500The coating Thickness Gauge unit can be used with a wide range of transducers, different calibration methods and evaluation options for a wide range of tasks in the field of coating measurement.

      Non-destructive measurement covers the following measurement ranges:


      0 - 50 mm for non-magnetic coating on steel

      0 - 100 mm for insulating coatings on non-ferrous metals

      Heat-resistant probes are suitable for temperatures up to 250°C and 350°C

      Pencil-shaped probes are measured in tubes and tubes

      All probes are equipped with wear bars to ensure long service life on abrasive substrates.


      MiniTest 2500 andMiniTest 4500Both models are equipped with a huge data memory that can store up to 2 million measured values, which can be in direct mode (MiniTest 2500) or classified as an APPLICATION-BATCH memory structure.


      Data transfer to PC via USB interface; The MiniTest 4500 also offers Bluetooth connectivity.


      The ergonomic design, clear display, one-touch operation and illuminated keypad, among other practical features, add high customer value to the MiniTest 2500-4500 meter series.

      apply

      NDT Thickness Gauges are suitable for:

      Non-magnetic coating on steel

      Insulating coatings on non-ferrous metals

      Copper layer on an insulating substrate

      Powder coatings on steel and non-ferrous metals

      features

      A wide range of wear-resistant probes are available for a variety of applications

      Universal probes with automatic substrate inspection can quickly measure steel and non-ferrous metals

      Wear-resistant special probes with virtually unlimited service life

      High measurement accuracy and high repeatability

      Store and evaluate the measured values

      Special calibration function for rough surfaces and calibration of unknown coating (CTC method)


      VS

      ElektroPhysik MiniTest 4500 Coating Thickness GaugeSpecifications

      LIST VALUE
      Calibrated mode Factory calibrated, zero and up to four calibrated points, if no substrate is used, calibrated by coating (CTC)
      Alarm function Optical and audible signal alarms when limits are exceeded
      Unit display μm/mm/cm/mils/inch
      statistical function kvar, n, max., min. kvar, n, max., min
      compensation function Used to add/subtract a constant value from a reading
      Interface USB and Bluetooth 4.0
      Data storage 200W, can be grouped over 9500
      Power Supply 3 * AA (LR06) battery, USB
      Standards DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882; ISO 19840; ASTM B 244, B 499, D 7091, E376
      Display screen 53 x 46 mm, backlit
      Operating temperature -10~60℃
      Storage temperature -20~70℃
      Battery life 150 hours (without backlighting)
      Protection level IP65
      Weight 320G (including battery)
      Dimension 153*89*36mm

      ElektroPhysik MiniTest 4500 Coating Thickness Gauge Packing list

      machine X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Coating thickness test on titanium alloy, Coating thickness 15~ 25mm, the equipment bought before can't measure titanium alloy, I don't know if it is not suitable for side F type
      [A]
      Pure titanium is non-magnetic or weakly magnetic. It is more suitable to use an N probe. It can be equipped with a probe N20 that measures 0-20mm, or a larger range of 0-100mm.
      [Q]
      Where can I buy the MiniTest 4500 Coating thickness gauge?
      [A]
      Hello, if there is a combination sale under the host, you can choose the probe, or you can consult NBchao customer service.
      [Q]
      Does the EPK MiniTest4500 Coating thickness gauge come standard with Bluetooth function?
      [A]
      Hello, yes.
      [Q]
      Meet ISO2178 Coating thickness gauge
      [A]
      MiniTest 4500 Coating thickness gauge, please refer to it.
      ElektroPhysik
      EPK MiniTest 4500 Coating Thickness Gauge can be grouped and calibrated with compensation/Bluetooth/sound and light alarm
      Service